NextSDS Logo
Safety Data Sheet EN

HYDROWAX 540

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
HYDROWAX 540

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Raw material for industry

Manufacturers & Suppliers

H

Hywax GmbH

manufacturer

Worthdamm 13 - 27, 20457 Hamburg, Germany

+49-40-78115-0

Emergency Contacts

Emergency Contact

+49-171-429-3850

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

dispersion

Chemical Name CAS Number Concentration Hazardous
2,2'-iminodiethanol EC: 203-868-0 111-42-2 0.1 - 1% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Do not breathe vapours or spray mist. If symptoms persist, call a physician.

Skin contact

Take off contaminated clothing and shoes immediately. Wash off with soap and water.

Eye contact

Protect unharmed eye. Remove contact lenses. Flush eyes with water as a precaution. Keep eye wide open while rinsing. If eye irritation persists, consult a specialist.

Ingestion

If accidentally swallowed obtain immediate medical attention. If symptoms persist, call a physician. Clean mouth with water and drink afterwards plenty of water.

Immediate Medical Attention

If accidentally swallowed obtain immediate medical attention.

Medical Treatment

Treat symptomatically.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Carbon dioxide (CO2), Dry powder, Foam, Sand, Water mist, Water spray jet

Unsuitable media

High volume water jet

Specific hazards

Do not allow run-off from fire fighting to enter drains or water courses.

Instructions

Standard procedure for chemical fires. Use extinguishing measures that are appropriate to local circumstances and the surrounding environment.

Firefighter Protection

Wear self-contained breathing apparatus for firefighting if necessary.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Environmental

Avoid subsoil penetration. Do not allow contact with soil, surface or ground water. If the product contaminates rivers and lakes or drains inform respective authorities.

Cleanup methods

Soak up with inert absorbent material.

Materials: sand, silica gel, acid binder, universal binder, sawdust

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Avoid formation of aerosol. No special handling advice required.

Storage

Keep containers tightly closed in a dry, cool and well-ventilated place. Keep away from heat and sources of ignition. Protect from frost, heat and sunlight.

Fire prevention

Keep away from open flames, hot surfaces and sources of ignition. Normal measures for preventive fire protection.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Hands

Material: Chemical resistant gloves made of butyl rubber or nitrile rubber category III according to EN 374. Take note of the information given by the producer concerning permeability and break through times, and of special workplace conditions (mechanical strain, duration of contact).

Eyes

Safety glasses with side-shields conforming to EN166

Respiratory

Breathing apparatus needed only when aerosol or mist is formed. Respiratory protection complying with EN 143.

Skin/Body

Long sleeved clothing

Environmental

Avoid subsoil penetration. Do not allow contact with soil, surface or ground water. If the product contaminates rivers and lakes or drains inform respective authorities.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
---
Colour
off-white
Colour Intensity
---
Form
dispersion
Odor
ammoniacal
Odor Threshold
Not relevant
Ph
ca. 9.5; ca. 20 °C; DIN 51369
Melting Point
0 - 4 °C
Boiling Point
ca. 100 °C
Flash Point
Not applicable
Freezing Point
0 - 4 °C
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
No data available
Vapor Pressure
23 hPa
Vapor Density
---
Relative Density
not determined
Bulk Density
---
Density
ca.0.95 g/cm3; 20 °C
Flammability
---
Upper Explosive Limit
Not applicable
Lower Explosive Limit
Not applicable
Explosive Limits
---
Auto Ignition Temperature
---
Decomposition Temperature
---
Solubility
not determined
Partition Coefficient
log Pow: > 3.5
Solubility In Water
partly miscible
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
50 - 600 mPas; ca. 20 °C; DIN 51398
Kinematic Viscosity
not determined
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

No decomposition if stored and applied as directed.

Reactivity

Stable under recommended storage conditions.

Hazardous reactions

None known.

Avoid

Protect from frost, heat and sunlight.

Incompatible

Oxidizing agents; Acids and bases

Decomposition

No decomposition if stored and applied as directed.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

If recycling is not practicable, dispose of in compliance with local regulations.

Disposal

If recycling is not practicable, dispose of in compliance with local regulations.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for HYDROWAX 540?

The signal word is no signal word.

What is the physical form of HYDROWAX 540?

HYDROWAX 540 is a liquid with off-white color. It has ammoniacal odor.

What is the solubility of HYDROWAX 540?

not determined

What is HYDROWAX 540 used for?

Raw material for industry

What is the melting point of HYDROWAX 540?

The melting point is 0 - 4 °C and the boiling point is ca. 100 °C.