Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- PressurePro Active Cleaner, alkaline RM 81
Regulatory Identifiers
- CAS Number
- N/A
- UFI Code
- T440-F0W4-Y00T-K7F4
Identified Uses
High pressure cleaner
Uses advised against
No further relevant information available.
Manufacturers & Suppliers
Alfred Kärcher SE & Co. KG
manufacturer
Alfred-Kärcher-Str. 28-40 D - 71364 Winnenden
+49-7195-14-0
www.karcher.com
Emergency Contacts
CHEMTREC
1-800-424-9300
Day or Night
CHEMTREC
+1 703-741-5970
Day or Night
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS05
Hazard Statements
Precautionary Statements
Manage your Safety Data Sheets
Organize and access chemical safety data with ease
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
Cleaning agent
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| sodium p-cumenesulphonate EC: 239-854-6 | 15763-76-5 | 1 - 5% | Yes |
| fatty alcohol ethoxylate | 78330-20-8 | 3 - 5% | Yes |
| isotridecanolethoxylate + 8 EO | 69011-36-5 | 1 - 3% | Yes |
| N/A | --- | 5 - 15% | No |
| N/A | --- | 5% | No |
| N/A | --- | --- | No |
For the wording of the listed hazard phrases refer to section 16.
First Aid Measures
Emergency procedures for chemical exposure incidents
Supply fresh air; consult doctor in case of complaints.
Rinse opened eye for several minutes under running water.
Rinse out mouth and then drink plenty of water. If symptoms persist consult doctor.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
CO2, powder or water spray. Fight larger fires with water spray or alcohol resistant foam.
Firefighter Protection
No special measures required.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Not required.
Dilute with plenty of water. Do not allow to enter sewers/ surface or ground water. Do not allow to penetrate the ground/soil.
Absorb with liquid-binding material
Materials: liquid-binding material (sand, diatomite, acid binders, universal binders)
Related Products
Similar products with comparable safety profiles
PressurePro Active Cleaner, alkaline RM 81
---
Restore Alkaline Cleaner - Heavy Duty
---
RS Pro Ultrasonic Cleaning Liquid
UFI: 44R7-J06P-U004-KM5N
neodisher LaboClean A 8
---
neodisher LaboClean A 8
---
MICRO-90 Concentrated Cleaning Solution
---
MR 79 Special Cleaner Aerosol
---
Electronic Cleaning Solvent Plus
---
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Ensure good ventilation/exhaustion at the workplace. Prevent formation of aerosols. Avoid contact with eyes and skin.
Store only in the original receptacle. Keep receptacle tightly sealed.
No special measures required.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
No further data; see section 7.
Not required.
Tightly sealed goggles (EN 166)
Not necessary if room is well-ventilated.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
No decomposition if used according to specifications.
Strong exothermic reaction with acids; Reacts with light alloys to form hydrogen; Corrodes aluminium
Strong exothermic reaction with acids; Reacts with light alloys to form hydrogen; Corrodes aluminium
No further relevant information available.
Not compatible with alkali-sensitive substances like Sn, Zn, Al and paintings.
No dangerous decomposition products known
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- UN3267
- Shipping Name
- CORROSIVE LIQUID, BASIC, ORGANIC, N.O.S. (methylglycine diacetic acid, trisodium salt, solution)
- Transport Class
- 8
- Packing Group
- III
Warning: Corrosive substances.
Warning: Corrosive substances.
Warning: Corrosive substances.
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for PressurePro Active Cleaner, alkaline RM 81?
The signal word is warning.
What is the physical form of PressurePro Active Cleaner, alkaline RM 81?
PressurePro Active Cleaner, alkaline RM 81 is a liquid appearing as fluid with yellow color. It has citrus-like odor.
What is the solubility of PressurePro Active Cleaner, alkaline RM 81?
Fully miscible
What is PressurePro Active Cleaner, alkaline RM 81 used for?
High pressure cleaner
What are the hazard statements for PressurePro Active Cleaner, alkaline RM 81?
This substance has 2 hazard statements:
- H290: May be corrosive to metals.
- H319: Causes serious eye irritation.
What is the melting point of PressurePro Active Cleaner, alkaline RM 81?
The melting point is -8 °C and the boiling point is 100 °C.