Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- PressurePro Active Cleaner, alkaline RM 81
Regulatory Identifiers
- CAS Number
- N/A
- UFI Code
- T440-F0W4-Y00T-K7F4
Identified Uses
High pressure cleaner
Uses advised against
No further relevant information available.
Manufacturers & Suppliers
Alfred Kärcher SE & Co. KG
manufacturer
Alfred-Kärcher-Str. 28-40, D - 71364 Winnenden
+49-7195-14-0
http://www.karcher.com
Emergency Contacts
CHEMTREC
1-800-424-9300
CHEMTREC
+1 703-741-5970
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS05
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
Cleaning agent
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| sodium p-cumenesulphonate EC: 239-854-6 | 15763-76-5 | 1 - 5% | Yes |
| fatty alcohol ethoxylate | 78330-20-8 | 3 - 5% | Yes |
| isotridecanolethoxylate + 8 EO | 69011-36-5 | 1 - 3% | Yes |
Regulation (EC) No 648/2004 on detergents / Labelling for contents: non-ionic surfactants (≥5 - <15%), anionic surfactants (<5%), perfumes.
First Aid Measures
Emergency procedures for chemical exposure incidents
Supply fresh air; consult doctor in case of complaints.
Rinse opened eye for several minutes under running water.
Rinse out mouth and then drink plenty of water. If symptoms persist consult doctor.
Immediate Medical Attention
If symptoms persist consult doctor.
Medical Treatment
No further relevant information available.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
CO2, powder or water spray. Fight larger fires with water spray or alcohol resistant foam.
No further relevant information available.
Firefighter Protection
No special measures required.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Dilute with plenty of water. Do not allow to enter sewers/ surface or ground water. Do not allow to penetrate the ground/soil.
Absorb with liquid-binding material (sand, diatomite, acid binders, universal binders).
Materials: sand, diatomite, acid binders, universal binders
Related Products
Similar products with comparable safety profiles
PressurePro Active Cleaner, alkaline RM 81
---
PressurePro Active cleaner, neutral RM 55
---
Restore Alkaline Cleaner - Heavy Duty
---
RS Pro Ultrasonic Cleaning Liquid
UFI: 44R7-J06P-U004-KM5N
MR® 79 Special Cleaner
---
neodisher LaboClean A 8
---
neodisher LaboClean A 8
---
Electronic Cleaning Solvent Plus
---
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Avoid contact with eyes and skin.
Store only in the original receptacle. Keep receptacle tightly sealed.
No special measures required.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
No further data; see section 7.
Not required. Material of gloves: Not required. Penetration time of glove material: Not required.
Tightly sealed goggles (EN 166)
Not necessary if room is well-ventilated.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
No decomposition if used according to specifications.
corresponds to 10.3
Strong exothermic reaction with acids, Reacts with light alloys to form hydrogen, Corrodes aluminium
No further relevant information available.
Not compatible with alkali-sensitive substances like Sn, Zn, Al and paintings.
No dangerous decomposition products known
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Must be specially treated adhering to official regulations.
Must not be disposed together with household garbage. Do not allow product to reach sewage system.
Waste Codes
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- UN3267
- Shipping Name
- CORROSIVE LIQUID, BASIC, ORGANIC, N.O.S. (methylglycine diacetic acid, trisodium salt, solution)
- Transport Class
- 8
- Packing Group
- III
Warning: Corrosive substances.
Warning: Corrosive substances.
Warning: Corrosive substances.
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Employment restrictions concerning juveniles must be observed.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for PressurePro Active Cleaner, alkaline RM 81?
The signal word is warning.
What is the physical form of PressurePro Active Cleaner, alkaline RM 81?
PressurePro Active Cleaner, alkaline RM 81 is a liquid appearing as fluid with yellow color. It has citrus-like odor.
What is the solubility of PressurePro Active Cleaner, alkaline RM 81?
Fully miscible
What is PressurePro Active Cleaner, alkaline RM 81 used for?
High pressure cleaner
What are the hazard statements for PressurePro Active Cleaner, alkaline RM 81?
This substance has 2 hazard statements:
- H290: May be corrosive to metals.
- H319: Causes serious eye irritation.
What is the melting point of PressurePro Active Cleaner, alkaline RM 81?
The melting point is -8 °C and the boiling point is 100 °C.