Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Tracer® UV Additive
- Product Code
- TP-3820-100, TP-3820-150, TP-3820-500
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Fluorescent, Leak detector, Paint
Uses advised against
No information available at present.
Manufacturers & Suppliers
Dometic Germany GmbH
manufacturer
Hollefeldstr. 63, 48282 Emsdetten
+49 (0) 2572 879 0
http://www.waeco.com
Dometic UK Ltd
distributor
Dometic House, The Brewery, GB-DT11 9LS Blandford St Mary, Dorset
+44 (0) 0844 626 0133
http://www.airconstations.co.uk
Emergency Contacts
National Poisons Information Centre, Beaumont Hospital, Dublin 9, Ireland
+353 (0)1 809 2166
8am-10pm, 7 days a week
National Poisons Information Centre, Beaumont Hospital, Dublin 9, Ireland
+353 (0)1 809 2566
24 h, 7 days a week
CCWA
+49 (0) 700 / 24 112 112
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
Polyalkylene glycols and additives
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Polyalkylene glycols and additives | --- | --- | No |
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove person from danger area. Supply person with fresh air and consult doctor according to symptoms.
Symptoms: Irritation of the respiratory tract, Irritant to mucosa of the nose and throat
Remove polluted, soaked clothing immediately, wash thoroughly with plenty of water and soap.
Symptoms: irritation of the skin (flare)
Remove contact lenses. Wash thoroughly for several minutes using copious water. Seek medical help if necessary.
Symptoms: Irritation of the eyes
Rinse the mouth thoroughly with water. Do not induce vomiting. Consult doctor immediately.
Symptoms: Danger of aspiration.
Immediate Medical Attention
Consult doctor immediately (Ingestion), consult doctor according to symptoms (Inhalation), consult a doctor (Skin), Seek medical help if necessary (Eye).
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
CO2, Dry extinguisher, Alcohol resistant foam, Water jet spray
High volume water jet
In case of fire the following can develop: Oxides of carbon, Oxides of nitrogen, Toxic gases.
Cool container at risk with water.
Firefighter Protection
Protective respirator with independent air supply. According to size of fire Full protection, if necessary.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Leave the danger zone if possible, use existing emergency plans if necessary.
If leakage occurs, dam up. Prevent surface and ground-water infiltration, as well as ground penetration. Prevent from entering drainage system.
Soak up with absorbent material
Materials: universal binding agent, sand, diatomaceous earth
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Avoid aerosol formation. Ensure good ventilation. Do not heat to temperatures close to flash point. Avoid long lasting or intensive contact with skin. Do not carry cleaning cloths soaked in product in trouser pockets. Observe directions on label and instructions for use.
Store product closed and only in original packing. Not to be stored in gangways or stair wells. Protect against moisture and store closed. Store cool. Protect from direct sunlight and warming.
General hygiene measures for the handling of chemicals are applicable. Wash hands before breaks and at end of work. Keep away from food, drink and animal feedingstuffs. Remove contaminated clothing and protective equipment before entering areas in which food is consumed. Eating, drinking, smoking, as well as food-storage, is prohibited in work-room.
Do not heat to temperatures close to flash point.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Ensure good ventilation. This can be achieved by local suction or general air extraction. If this is insufficient to maintain the concentration under the WEL or AGW values, suitable breathing protection should be worn. Applies only if maximum permissible exposure values are listed here.
Chemical resistant protective gloves (EN ISO 374). If applicable Protective nitrile gloves (EN ISO 374). Minimum layer thickness in mm: 0,35 Permeation time (penetration time) in minutes: >= 480 Protective hand cream recommended. The breakthrough times determined in accordance with EN 16523-1 were not obtained under practical conditions. The recommended maximum wearing time is 50% of breakthrough time. Additional information on hand protection - No tests have been performed. In the case of mixtures, the selection has been made according to the knowledge available and the information about the contents. Selection of materials derived from glove manufacturer's indications. Final selection of glove material must be made taking the breakthrough times, permeation rates and degradation into account. Selection of a suitable glove depends not only on the material but also on other quality characteristics and varies from manufacturer to manufacturer. In the case of mixtures, the resistance of glove materials cannot be predicted and must therefore be tested before use. The exact breakthrough time of the glove material can be requested from the protective glove manufacturer and must be observed.
Tight fitting protective goggles with side protection (EN 166).
Normally not necessary. If OES or MEL is exceeded. Filter A2 P2 (EN 14387), code colour brown, white Observe wearing time limitations for respiratory protection equipment.
Protective working garments (e.g. safety shoes EN ISO 20345, long-sleeved protective working garments).
No information available at present.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable with proper storage and handling.
The product has not been tested.
No decomposition if used as intended.
Strong heat
strong oxidizing agents, Reducing agent
No decomposition when used as directed.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
E.g. suitable incineration plant.
Sewage disposal shall be discouraged. Pay attention to local and national official regulations.
Waste Codes
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- n.a.
- Transport Class
- n.a.
- Packing Group
- n.a.
Regulatory Information
Chemical regulations, safety assessments, and compliance status
General hygiene measures for the handling of chemicals are applicable.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Tracer® UV Additive?
The signal word is no signal word.
What is the physical form of Tracer® UV Additive?
Tracer® UV Additive is a liquid with amber color. It has characteristic odor.
What is the solubility of Tracer® UV Additive?
Not determined
What is Tracer® UV Additive used for?
Fluorescent, Leak detector, Paint
What is the melting point of Tracer® UV Additive?
The melting point is Not determined and the boiling point is Not determined.