NextSDS Logo
Safety Data Sheet EN

Biopsy Medium

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Biopsy Medium
Product Code
1062

Regulatory Identifiers

CAS Number
N/A

Identified Uses

For blastomere biopsy of cleavage stage embryos for Pre-implantation Genetic Diagnosis (PGD)

Manufacturers & Suppliers

O

ORIGIO a/s

manufacturer

Knardrupvej 2, DK-2760 Måløv

+45 46 79 02 00

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Water --- 95% No
Sodium Chloride 7647-14-5 1% No
HEPES Sodium Salt 75277-39-3 1% No
HEPES free acid 7365-45-9 1% No
Human Serum Albumin --- 1% No
Sodium Bicarbonate 144-55-8 1% No
Amino Acids --- 0.1% No
Zinc Sulphate 7446-20-0 0.1% No
Glucose 492-62-6 0.1% No
Potassium Chloride 7447-40-7 0.1% No
SSR® (Synthetic Serum Replacement) --- 0.1% No
Choline Chloride 67-48-1 0.1% No
Sodium Selenite 10102-18-8 0.01% No
Ammonium Metavanadate 7803-55-6 0.01% No
Molybdic Acid 12054-85-2 0.01% No
Manganese Sulphate 10034-96-5 0.01% No
Gentamicin Sulphate 1405-41-0 0.01% No
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Not a likely source of exposure.

Skin contact

Wash with soap and water after each contact.

Eye contact

Flush with copious amounts of water. Assure adequate flushing by separating the eyelids with fingers. If irritation develops, consult a physician.

Ingestion

Wash out mouth with water. If swallowed consult a physician.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Dry chemical, foam, carbon dioxide or water spray.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Cleanup methods

Absorb on suitable absorbent, such as paper tissue.

Materials: paper tissue

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Storage

Store in original container at 2-8°C, protected from light. Do not freeze.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

The data for this section has not been processed yet.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Density
---
Physical State Data
liquid
Form
---
Relative Evaporation Rate
---
Flammability
---
Appearance
A clear, colourless liquid
Partition Coefficient
---
Dynamic Viscosity
---
State Under Standard Conditions
---
Properties Status
---
Solubility In Fat
---
Physical State
liquid
Colour
colourless
Bulk Density
---
Odor Threshold
---
Lower Explosive Limit
---
Ph
---
Solubility
---
Freezing Point
---
Kinematic Viscosity
---
Odor
Odourless
Colour Intensity
---
Cloud Point
---
Metal Corrosion
---
Vapor Pressure
---
Solidification Point
---
Decomposition Temperature
---
Upper Explosive Limit
---
Vapor Density
---
Molecular Weight
---
Auto Ignition Temperature
---
Softening Point
---
Crystallisation Point
---
Melting Point
---
Flash Point
---
Relative Density
---
Boiling Point
---
Solubility In Water
Soluble
Explosive Limits
---
Voc Content
---
Evaporation Rate
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable

Hazardous reactions

Not expected to occur

Avoid

None known

Decomposition

None known

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Biopsy Medium?

The signal word is no signal word.

What is the physical form of Biopsy Medium?

Biopsy Medium is a liquid appearing as a clear, colourless liquid with colourless color. It has odourless odor.

What is Biopsy Medium used for?

For blastomere biopsy of cleavage stage embryos for Pre-implantation Genetic Diagnosis (PGD)