Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- RUBIA OPTIMA 1100 15W40
- Product Code
- 086690
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Engine oil.
Uses advised against
Do not use for any purpose other than the one for which it is intended
Manufacturers & Suppliers
TOTAL Specialties USA Inc
1201 Louisiana Street, Suite 1800, Houston, TX 77002
+1 800 323 3198
Emergency Contacts
TOTAL Specialties USA Inc
+1 (908) 862-9300
Emergency Contact
+1 866 928 0789
24h/24, 7d/7
Emergency Contact
+1 215 207 0061
24h/24, 7d/7
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Distillates (petroleum), solvent-dewaxed heavy paraffinic | 64742-65-0 | 5 - 10% | No |
| reaction mass of isomers of: C7-9-alkyl 3-(3,5-di-trans-butyl-4-hydroxyphenyl)propionate | 125643-61-0 | 2.5 - 5% | No |
| bis(nonylphenyl)amine | 36878-20-3 | 1 - 2.5% | No |
| Zinc bis[O-(6-methylheptyl)] bis[O-(sec-butyl)] bis(dithiophosphate) | 93819-94-4 | 1 - 2.5% | No |
| Molybdene dithiocarbamide complex, polysulfur alkyl long chain | --- | 0.1 - 0.3% | No |
Product containing mineral oil with less than 3% DMSO extract as measured by IP 346
First Aid Measures
Emergency procedures for chemical exposure incidents
Move to fresh air.
Symptoms: Not classified. Symptoms of overexposure are dizziness, headache, tiredness, nausea, unconsciousness, cessation of breathing.
Rinse immediately with plenty of water and seek medical advice.
Symptoms: Not classified.
Rinse immediately with plenty of water and seek medical advice.
Symptoms: Not classified. The supplier of some components contained within this formulation has indicated that the classification as irritant is not required.
Do not induce vomiting. If conscious, give 2 glasses of water. Get immediate medical attention.
Symptoms: Not classified. Ingestion may cause gastrointestinal irritation, nausea, vomiting and diarrhea.
Immediate Medical Attention
Get immediate medical attention.
Medical Treatment
Treat symptomatically.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use CO2, dry chemical, or foam.
Do not use a solid water stream as it may scatter and spread fire.
Incomplete combustion and thermolysis may produce gases of varying toxicity such as carbon monoxide, carbon dioxide, various hydrocarbons, aldehydes and soot. These may be highly dangerous if inhaled in confined spaces or at high concentration.
Evacuate non-essential personnel.
Firefighter Protection
As in any fire, wear self-contained breathing apparatus pressure-demand, MSHA/NIOSH (approved or equivalent) and full protective gear.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
See Section 12 for additional Ecological Information.
collect with non-combustible absorbent material
Materials: non-combustible absorbent material (e.g. sand, earth, diatomaceous earth, vermiculite)
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Ensure adequate ventilation. Handle in accordance with good industrial hygiene and safety practice. Wear suitable gloves and eye/face protection. Avoid breathing vapors, mist or gas.
Keep container tightly closed in a dry and well-ventilated place. Store in original container.
When using, do not eat, drink or smoke. Wear suitable gloves and eye/face protection. Wash hands before breaks and at the end of workday. Wash hands with water as a precaution. Regular cleaning of equipment, work area and clothing is recommended.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Apply technical measures to comply with the occupational exposure limits.
Protective gloves.
If splashes are likely to occur, wear: Safety glasses with side-shields.
If exposure limits are exceeded or irritation is experienced, NIOSH/MSHA approved respiratory protection should be worn. Positive-pressure supplied air respirators may be required for high airborne contaminant concentrations. Respiratory protection must be provided in accordance with current local regulations.
Wear suitable protective clothing. Protective shoes or boots.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under recommended storage conditions.
No information available.
None under normal processing.
Heat, flames and sparks. Take precautionary measures against static discharges.
Strong oxidizing agents. Strong reducing agents. Strong acids. Strong bases.
None under normal use.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for RUBIA OPTIMA 1100 15W40?
The signal word is no signal word.
What is the physical form of RUBIA OPTIMA 1100 15W40?
RUBIA OPTIMA 1100 15W40 is a liquid appearing as limpid with no information available color. It has characteristic odor.
What is RUBIA OPTIMA 1100 15W40 used for?
Engine oil.
What is the melting point of RUBIA OPTIMA 1100 15W40?
The melting point is No information available and the boiling point is No information available.