Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- IMAPUR HS 03
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Solvent-based aromatic polyurethane resin
Manufacturers & Suppliers
IMA S.R.L.
manufacturer
Via Segrè, 23, 27036 Mortara, Italia
0384 29.73.11
Emergency Contacts
Emergency Contact
0384/297311
orario d'ufficio / office hours
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| N-METHYL-2-PYRROLIDONE EC: 212-828-1 | 872-50-4 | 14 - 16% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove to open air. If breathing is irregular, seek medical advice.
Wash immediately with plenty of water. Remove contaminated clothing. If irritation persists, seek medical attention. Wash contaminated clothing before using them again.
Irrigate copiously with clean, fresh water for at least 15 minutes. Seek medical advice.
Obtain immediate medical attention. Induce vomiting only if indicated by the doctor. Never give anything by mouth to an unconscious person.
Immediate Medical Attention
Obtain immediate medical attention. Seek medical advice.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
carbon dioxide, foam, powder and nebulised water.
Do not use jets of water.
Excess pressure may form in containers exposed to fire at a risk of explosion. Do not breathe combustion products (carbon oxide, toxic pyrolysis products, etc).
Use jets of water to cool the containers to prevent product decomposition and the development of substances potentially hazardous for health.
Firefighter Protection
Always wear full fire prevention gear.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Block the leakage if there is no hazard. Do not handle damaged containers or the leaked product before donning appropriate protective gear.
The product must not penetrate the sewers, surface water, ground water and neighbouring areas.
Collect the majority of the remaining material and deposit it in containers for disposal.
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Do not smoke while handling and use.
Store in a well ventilated place, keep far away from sources of heat, bright flames and sparks and other sources of ignition.
keep far away from sources of heat, bright flames and sparks and other sources of ignition.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
As the use of adequate technical equipment must always take priority over personal protection equipment, make sure that the workplace is well aired through effective local aspiration or bad air vent. The product must be used in a closed cycle, in well-aired environments fitted with strong localised aspiration systems (capture speed > 1.5 m/s).
Protect hands with category III (ref. Directive 89/686/EEC and standard EN 374) work gloves, such as those in PVA, butyl, fluoroelastomer or equivalent. The following should be considered when choosing work glove material: degradation, breakage times and permeation. Work glove resistance to preparations should be checked before use, as it can be unpredictable. Gloves' limit depends on the duration of exposure.
Wear hood visor or protective visor together with airtight goggles (ref. standard EN 166)
If the threshold value for one or more of the substances present in the preparation for daily exposure in the workplace or to a fraction established by the company's prevention and protection service is exceeded, wear a mask with an A or universal filter, the class (1, 2 or 3) of which must be chosen according to the limit concentration of use (ref. standard EN 141). The use of breathing protection equipment, such as masks with organic vapour and dust/mist cartridges, is necessary in the absence of technical measures limiting worker exposure. If the substance in question is odourless or its olfactory threshold is higher than the relative exposure limit and in the event of an emergency, or when exposure levels are unknown or the concentration of oxygen in the workplace is less than 17% volume, wear self-contained, open-circuit compressed air breathing apparatus (ref. standard EN 137) or fresh air hose breathing apparatus for use with full face mask, half mask or mouthpiece (ref. standard EN 138).
Wear category III professional long-sleeved overalls and safety footwear (ref. Directive 89/686/CEE and standard EN 344). Wash body with soap and water after removing overalls.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
The product is stable in normal conditions of use and storage. N-METHYL-2-PYRROLIDONE: stable up to 315°C in inerte atmospheres.
decomoses at temperatures over 300°C. When exposed to the air it oxidates slowly to develop hydroperoxides. Completely mixable with water with a neutral or slightly basic reaction. It does not attack common materials but does dissolve several kinds of plastic materials.
The vapours may also form explosive mixtures with the air. N-METHYL-2-PYRROLIDONE: may react dangerously with strong oxidants and strong acids.
Sulphur and carbon disulphide. Oxidising substances, rubbers, plastics, aluminium and some metals.
In the event of thermal decomposition or fire, vapours potentially dangerous to health may be released. N-METHYL-2-PYRROLIDONE: nitric oxides, carbon oxides.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for IMAPUR HS 03?
The signal word is na: r-phrases.
What is the physical form of IMAPUR HS 03?
IMAPUR HS 03 is a viscous liquid appearing as viscous liquid with slightly yellow color. It has characteristic odor.
What is IMAPUR HS 03 used for?
Solvent-based aromatic polyurethane resin
What is the melting point of IMAPUR HS 03?
The melting point is Not available and the boiling point is 202 °C.