Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- AEM 5700
- Product Form
- Mixture
- Product Code
- DA6
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Professional use, Industrial use; Textile industries; Biocide
Uses advised against
No additional information available
Manufacturers & Suppliers
Devan Chemicals N.V.
manufacturer
Ninoofsesteenweg 539, 9600 Ronse - België
+32 55 23 01 10
http://www.devan.net
Emergency Contacts
Centre Anti-Poisons/Antigifcentrum c/o Hôpital Central de la Base - Reine Astrid
+32 70 245 245
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS02
GHS06
GHS08
GHS09
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| methanol | 67-56-1 | 50% | Yes |
| dimethyloctadecyl(3-(trimethoxysilyl)propyl)ammoniumchloride | 27668-52-6 | 42% | Yes |
| 3-chloorpropyltrimethoxysilaan | 2530-87-2 | 8% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove victim to fresh air and keep at rest in a position comfortable for breathing. Immediately call a POISON CENTER or doctor/physician. Specific treatment (see ... on this label).
Symptoms: Toxic if inhaled. Danger of serious damage to health by prolonged exposure through inhalation.
Rinse skin with water/shower. Remove/Take off immediately all contaminated clothing. Immediately call a POISON CENTER or doctor/physician. Wash with plenty of soap and water. Specific measures (see ... on this label). Wash contaminated clothing before reuse.
Symptoms: Repeated exposure to this material can result in absorption through skin causing significant health hazard. Toxic in contact with skin.
Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. If eye irritation persists: Get medical advice/attention.
Symptoms: Causes serious eye irritation.
Rinse mouth. Do NOT induce vomiting. Obtain emergency medical attention. Immediately call a POISON CENTER or doctor/physician. Specific treatment (see ... on this label).
Symptoms: Toxic if swallowed. Swallowing a small quantity of this material will result in serious health hazard.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Foam. Dry powder. Carbon dioxide. Water spray. Sand.
Do not use a heavy water stream.
Highly flammable liquid and vapour. May form flammable/explosive vapour-air mixture.
Use water spray or fog for cooling exposed containers. Exercise caution when fighting any chemical fire. Prevent fire-fighting water from entering environment.
Firefighter Protection
Do not enter fire area without proper protective equipment, including respiratory protection.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Evacuate unnecessary personnel.
Prevent entry to sewers and public waters. Avoid release to the environment.
Soak up spills with inert solids, such as clay or diatomaceous earth as soon as possible. Collect spillage.
Materials: inert solids, such as clay or diatomaceous earth
Related Products
Similar products with comparable safety profiles
AP/E CORE 2500
---
AP/E CORE 2500
CAS: 64742-57-0; 64742-62-7
AP/E CORE 2500
CAS: 64742-57-0; 64742-62-7
AP/E CORE 150
CAS: 64742-54-7; 64742-65-0
AP/E CORE 150
CAS: 64742-54-7; 64742-65-0
MasterEmaco P 5000AP
---
HiTEC® 5708 Performance Additive
UFI: 8C9Q-CM0P-742P-P8QF
AEP
CAS: 140-31-8
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Handle empty containers with care because residual vapours are flammable. Wash hands and other exposed areas with mild soap and water before eating, drinking or smoking and when leaving work. Provide good ventilation in process area to prevent formation of vapour. No open flames. No smoking. Use only non-sparking tools. Use only outdoors or in a well-ventilated area. Avoid breathing dust/fume/gas/mist/vapours/spray. Do not breathe dust/fume/gas/mist/vapours/spray.
Keep in fireproof place. Keep container tightly closed. Store in a dry, cool and well-ventilated place.
Do not eat, drink or smoke when using this product. Wash ... thoroughly after handling.
No open flames. No smoking. Use only non-sparking tools. Keep in fireproof place.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Wear protective gloves
Chemical goggles or safety glasses
Where exposure through inhalation may occur from use, respiratory protection equipment is recommended
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under normal conditions.
No additional information available
None under normal conditions.
Direct sunlight. Extremely high or low temperatures. Open flame.
Oxidizing agent.
fume. Carbon monoxide. Carbon dioxide. May release flammable gases.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 1230
- Shipping Name
- METHANOL
- Transport Class
- 3 (6.1)
- Packing Group
- II
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for AEM 5700?
The signal word is danger.
What is the physical form of AEM 5700?
AEM 5700 is a liquid with light yellow color. It has characteristic odor.
What is the solubility of AEM 5700?
No data available
What is AEM 5700 used for?
Professional use, Industrial use; Textile industries; Biocide
What are the hazard statements for AEM 5700?
This substance has 5 hazard statements:
- H225: Highly flammable liquid and vapour
- H301 + H311 + H331: Toxic if swallowed, in contact with skin or if inhaled
- H319: Causes serious eye irritation
- H370: Causes damage to organs
- H410: Very toxic to aquatic life with long lasting effects
What is the melting point of AEM 5700?