Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
RRE-570

Regulatory Identifiers

CAS Number
N/A
REACH No.
Not applicable (mixture)

Identified Uses

Detergent according to Regulation (EC) No 648/2004

Uses advised against

No uses advised against known

Manufacturers & Suppliers

N

Novatio

distributor

Industrielaan 5B, B-2250 Olen

+32 14 25 76 40

N

Novatech International N.V.

manufacturer

Industrielaan 5B, B-2250 Olen

+32 14 85 97 37

Emergency Contacts

BIG

+32 14 58 45 45

24h/24h

EN, FR, DE, NL

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
(1-hydroxyethylidene)bisphosphonic acid, potassium salt EC: 267-956-0 67953-76-8 30% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove victim into fresh air. In case of respiratory problems, consult a doctor/medical service.

Symptoms: No effects known.

Skin contact

If possible, wipe up/dry remove chemical. Then rinse/shower immediately with (lukewarm) water. If irritation persists, consult a doctor/medical service.

Symptoms: No effects known.

Eye contact

Rinse immediately with (lukewarm) water. Remove contact lenses, if present and easy to do. Continue rinsing. If irritation persists, consult a doctor/medical service.

Symptoms: No effects known.

Ingestion

Rinse mouth with water. Immediately consult a doctor/medical service. Do not wait for symptoms to occur to consult Poison Center.

Symptoms: Headache. Vomiting. Diarrhoea. Abdominal pain. Drowsiness.

Immediate Medical Attention

In case of injury and/or intoxication, call the European emergency number 112. Immediately consult a doctor/medical service for ingestion. Consult a doctor/medical service if irritation persists for skin/eye contact or if respiratory problems occur.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Small fire: Quick-acting ABC powder extinguisher, Quick-acting BC powder extinguisher, Quick-acting class B foam extinguisher, Quick-acting CO2 extinguisher. Major fire: Class B foam (alcohol-resistant), Water spray if puddle cannot expand.

Unsuitable media

Small fire: Water (quick-acting extinguisher, reel); risk of puddle expansion. Major fire: Water; risk of puddle expansion.

Specific hazards

On heating/burning: release of toxic and corrosive gases/vapours e.g.: phosphorus oxides, carbon monoxide - carbon dioxide.

Instructions

Dilute toxic gases with water spray. Take account of toxic/corrosive precipitation water.

Firefighter Protection

Gloves (EN 374). Protective clothing (EN 14605 or EN 13034). Heat/fire exposure: self-contained breathing apparatus (EN 136 + EN 137).

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Environmental

Contain released product, collect/pump into suitable containers. Plug the leak, cut off the supply.

Cleanup methods

Scoop absorbed substance into closing containers. Clean contaminated surfaces with an excess of water.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Keep away from naked flames/heat. Observe normal hygiene standards. Keep container tightly closed.

Storage

Keep container tightly closed.

Hygiene

Observe normal hygiene standards.

Fire prevention

Keep away from naked flames/heat.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Keep away from naked flames/heat. Measure the concentration in the air regularly. Carry operations in the open/under local exhaust/ventilation or with respiratory protection.

Hands

Protective gloves against chemicals (EN 374). Materials: nitrile rubber, >480 minutes, 0.35 mm, Class 6.

Eyes

Eye protection not required in normal conditions.

Respiratory

Respiratory protection not required in normal conditions.

Skin/Body

Protective clothing (EN 14605 or EN 13034).

Environmental

See sections 6.2, 6.3 and 13

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Bulk Density
---
Appearance
---
Solubility In Water
---
Softening Point
---
Lower Explosive Limit
---
Solubility In Fat
---
Solubility
Water ; complete
Voc Content
---
Decomposition Temperature
No data available in the literature
Form
Liquid
Ph
6.0
Properties Status
---
Odor Threshold
No data available in the literature
Cloud Point
---
State Under Standard Conditions
---
Molecular Weight
---
Density
1170 kg/m³ ; 20 °C
Freezing Point
---
Vapor Pressure
No data available in the literature
Colour
Colourless
Dynamic Viscosity
1 mPa.s ; 20 °C
Colour Intensity
---
Solidification Point
---
Metal Corrosion
---
Flash Point
No data available in the literature
Relative Density
1.17 ; 20 °C
Odor
Characteristic odour
Vapor Density
---
Physical State
Liquid
Flammability
Not classified as flammable
Evaporation Rate
0.300 ; Butyl acetate
Partition Coefficient
Not applicable (mixture)
Relative Evaporation Rate
---
Crystallisation Point
---
Auto Ignition Temperature
No data available in the literature
Melting Point
0 °C
Upper Explosive Limit
---
Boiling Point
100 °C
Kinematic Viscosity
1 mm²/s ; 40 °C
Physical State Data
liquid
Explosive Limits
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under normal conditions.

Reactivity

Heating increases the fire hazard.

Hazardous reactions

No data available.

Avoid

Keep away from naked flames/heat.

Incompatible

No data available.

Decomposition

On heating/burning: release of toxic and corrosive gases/vapours e.g.: phosphorus oxides, carbon monoxide - carbon dioxide.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for RRE-570?

The signal word is no signal word.

What is the physical form of RRE-570?

RRE-570 is a liquid with colourless color. It has characteristic odour odor.

What is the solubility of RRE-570?

Water ; complete

What is RRE-570 used for?

Detergent according to Regulation (EC) No 648/2004

What is the melting point of RRE-570?

The melting point is 0 °C and the boiling point is 100 °C.