NextSDS Logo
Safety Data Sheet EN

MagniF

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
MagniF
Synonyms
MagniF10, MagniF 25, MagniF 50, MagniF 150, MagniF 0.1, Magnetite, Magnetite 20E, Magnetite 30E, UFGM

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Water Treatment, Restricted to professional users.

Uses advised against

None known.

Manufacturers & Suppliers

LKAB Minerals Ltd. logo

LKAB Minerals Ltd.

manufacturer

Raynesway, DE21 7BE Derby, United Kingdom

+44 1332 673131

http://www.lkabminerals.com

Emergency Contacts

The National Poisons Information Service

111

24 h service

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Magnetite EC: 215-169-8 1309-38-2 80 - 95% No
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

In case of discomfort: bring the person into fresh air.

Skin contact

Upon irritation: rinse with water. In the event of continued irritation, seek medical assistance.

Eye contact

If in eyes: Flush eyes with plenty of water or salt water (20-30 °C) and continue until irritation stops. Remove contact lenses.

Ingestion

Rinse and flush mouth thoroughly and consume large quantities of water. In case of continued discomfort: seek medical assistance and bring this safety data sheet.

Immediate Medical Attention

Contact a doctor if in doubt about the injured person's condition or if the symptoms persist.

Medical Treatment

Treat symptomatically.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Alcohol-resistant foam, carbon dioxide, powder, water mist.

Unsuitable media

Waterjets should not be used, since they can spread the fire.

Specific hazards

None known.

Instructions

No specific requirements.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Contaminated areas may be slippery.

Environmental

Avoid discharge to lakes, streams, sewers, etc.

Cleanup methods

sweep up and shovel into appropriate containers for disposal. Wherever possible cleaning should be performed with normal cleaning agents. Avoid use of solvents.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Storage

Dry, cool and well ventilated

Hygiene

Smoking, drinking and consumption of food is not allowed in the work area.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Apply standard precautions during use of the product. Avoid inhalation of gas or dust.

Hands

Material: Gloves, Breakthrough time: >480 min, Standards: EN374

Eyes

Type: Safety glasses with side shields, Standards: EN166

Respiratory

Type: SL, Class: P3, Colour: White, Standards: EN149

Skin/Body

Dedicated work clothing should be worn.

Environmental

No specific requirements.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Lower Explosive Limit
No data available
Cloud Point
---
Boiling Point
Not applicable
Form
---
Auto Ignition Temperature
Not applicable
Voc Content
---
Vapor Pressure
Not applicable
Decomposition Temperature
Not applicable
Physical State
Solid
Properties Status
---
Relative Evaporation Rate
---
Appearance
---
Partition Coefficient
0
Colour Intensity
---
Softening Point
Does not apply to solids.
Physical State Data
solid
Density
---
Solubility In Water
Insoluble in water
Relative Density
5
Vapor Density
---
Upper Explosive Limit
No data available
Evaporation Rate
Not applicable
Solidification Point
---
Odor Threshold
---
Kinematic Viscosity
Not applicable - product is a solid
Metal Corrosion
---
Dynamic Viscosity
---
Flash Point
Not applicable
Flammability
Not applicable
Explosive Limits
---
Crystallisation Point
---
Colour
Black
Bulk Density
---
State Under Standard Conditions
---
Ph
No data available
Odor
---
Molecular Weight
---
Freezing Point
1400 - 1600 °C
Solubility In Fat
0 g/L
Solubility
---
Melting Point
1400 - 1600 °C
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

The product is stable under the conditions, noted in section 7 "Handling and storage".

Reactivity

No data available.

Hazardous reactions

None known.

Avoid

None known.

Incompatible

Strong acids, strong bases, strong oxidizing agents, and strong reducing agents.

Decomposition

The product is not degraded when used as specified in section 1.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What other names is MagniF known by?

MagniF is also known as: MagniF10, MagniF 25, MagniF 50, MagniF 150, MagniF 0.1, Magnetite, Magnetite 20E, Magnetite 30E, UFGM

What is the hazard signal word for MagniF?

The signal word is no signal word.

What is the physical form of MagniF?

MagniF is a solid with black color.

What is MagniF used for?

Water Treatment, Restricted to professional users.

What is the melting point of MagniF?

The melting point is 1400 - 1600 °C and the boiling point is Not applicable.