Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Ethylene glycol dimethyl ether
- Product Code
- 610350000; 610350010; 610351000
- Synonyms
- Monoglyme; 1,2-Dimethoxyethane
Regulatory Identifiers
- CAS Number
- 110-71-4 Check regulations →
- EC Number
- 203-794-9 Check regulations →
- REACH No.
- 01-2119485981-24
Identified Uses
Laboratory chemicals. Sector of use: SU3 - Industrial uses: Uses of substances as such or in preparations at industrial sites; Product category: PC21 - Laboratory chemicals; Process categories: PROC15 - Use as a laboratory reagent; Environmental release category: ERC6a - Industrial use resulting in manufacture of another substance (use of intermediates)
Uses advised against
No Information available
Manufacturers & Suppliers
Thermo Fisher Scientific
importer
Janssen Pharmaceuticalaan 3a, 2440 Geel, Belgium
Fisher Scientific UK
distributor
Bishop Meadow Road, Loughborough, Leicestershire LE11 5RG, United Kingdom
Fisher Scientific AG
distributor
Neuhofstrasse 11, CH 4153 Reinach
+41 (0) 56 618 41 11
Emergency Contacts
Emergency Contact
001-800-227-6701
Emergency Contact
+32 14 57 52 11
Emergency Contact
001-201-796-7100
Emergency Contact
+32 14 57 52 99
CHEMTREC
001-800-424-9300
CHEMTREC
001-703-527-3887
Tox Info Suisse
145
24hr
Tox Info Suisse
+41-44 251 51 51
Chemtrec
0800 564 402
24h
Chemtrec
+41-43 508 20 11
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS02
GHS07
GHS08
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Ethylene glycol dimethyl ether EC: 203-794-9 | 110-71-4 | 95% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove to fresh air. Do not use mouth-to-mouth method if victim ingested or inhaled the substance; give artificial respiration with the aid of a pocket mask equipped with a one-way valve or other proper respiratory medical device. Immediate medical attention is required. If not breathing, give artificial respiration.
Symptoms: Difficulty in breathing. Inhalation of high vapor concentrations may cause symptoms like headache, dizziness, tiredness, nausea and vomiting
Wash off immediately with plenty of water for at least 15 minutes. Immediate medical attention is required.
Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. Immediate medical attention is required.
Do NOT induce vomiting. Call a physician or poison control center immediately.
Immediate Medical Attention
Immediate medical attention is required.
Medical Treatment
Treat symptomatically.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Water spray, carbon dioxide (CO2), dry chemical, alcohol-resistant foam. Water mist may be used to cool closed containers.
No information available.
Flammable. Containers may explode when heated. Vapors may form explosive mixtures with air. Vapors may travel to source of ignition and flash back.
As in any fire, wear self-contained breathing apparatus pressure-demand, MSHA/NIOSH (approved or equivalent) and full protective gear. Thermal decomposition can lead to release of irritating gases and vapors.
Firefighter Protection
As in any fire, wear self-contained breathing apparatus pressure-demand, MSHA/NIOSH (approved or equivalent) and full protective gear.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Keep people away from and upwind of spill/leak. Evacuate personnel to safe areas.
Should not be released into the environment.
Soak up with inert absorbent material.
Materials: inert absorbent material
Related Products
Similar products with comparable safety profiles
Ethylene glycol diethyl ether
CAS: 629-14-1
Diethylene glycol dimethyl ether
CAS: 111-96-6
Ethylene glycol monopropyl ether
CAS: 2807-30-9
Diethylene glycol monoethyl ether
CAS: 111-90-0
Ethylene glycol dimethacrylate
CAS: 97-90-5
Ethylene glycol dimethacrylate
CAS: 97-90-5
Ethylene Glycol Dibutyl Ether
---
Diethylene glycol diethyl ether
CAS: 112-36-7
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Use only under a chemical fume hood. Wear personal protective equipment/face protection. Do not get in eyes, on skin, or on clothing. Do not ingest. If swallowed then seek immediate medical assistance. Do not breathe mist/vapors/spray. If peroxide formation is suspected, do not open or move container. Keep away from open flames, hot surfaces and sources of ignition. Use only non-sparking tools. To avoid ignition of vapors by static electricity discharge, all metal parts of the equipment must be grounded. Take precautionary measures against static discharges.
Keep containers tightly closed in a dry, cool and well-ventilated place. Containers should be dated when opened and tested periodically for the presence of peroxides. Should crystals form in a peroxidizable liquid, peroxidation may have occurred and the product should be considered extremely dangerous. In this instance, the container should only be opened remotely by professionals. Keep away from heat, sparks and flame.
Handle in accordance with good industrial hygiene and safety practice.
Keep away from open flames, hot surfaces and sources of ignition. Use only non-sparking tools. To avoid ignition of vapors by static electricity discharge, all metal parts of the equipment must be grounded. Take precautionary measures against static discharges.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Use only under a chemical fume hood. Ensure that eyewash stations and safety showers are close to the workstation location. Use explosion-proof electrical/ventilating/lighting/equipment. Ensure adequate ventilation, especially in confined areas. Wherever possible, engineering control measures such as the isolation or enclosure of the process, the introduction of process or equipment changes to minimise release or contact, and the use of properly designed ventilation systems, should be adopted to control hazardous materials at source
Protective gloves. Glove materials: Nitrile rubber, Neoprene, Natural rubber, PVC. Breakthrough time: See manufacturers recommendations. EU standard: EN 374 (minimum requirement).
Wear safety glasses with side shields (or goggles) (European standard - EN 166)
When workers are facing concentrations above the exposure limit they must use appropriate certified respirators. To protect the wearer, respiratory protective equipment must be the correct fit and be used and maintained properly. Large scale/emergency use: Use a NIOSH/MSHA or European Standard EN 136 approved respirator if exposure limits are exceeded or if irritation or other symptoms are experienced. Recommended Filter type: Organic gases and vapours filter Type A Brown conforming to EN14387. Small scale/Laboratory use: Use a NIOSH/MSHA or European Standard EN 149:2001 approved respirator if exposure limits are exceeded or if irritation or other symptoms are experienced. Recommended half mask: Valve filtering: EN405; or; Half mask: EN140; plus filter, EN 141. When RPE is used a face piece Fit Test should be conducted
Long sleeved clothing. Inspect gloves before use. Observe the instructions regarding permeability and breakthrough time which are provided by the supplier of the gloves. Gloves are suitable for the task: Chemical compatibility, Dexterity, Operational conditions, User susceptibility, e.g. sensitisation effects, also take into consideration the specific local conditions under which the product is used, such as the danger of cuts, abrasion. Handle gloves with care avoiding skin contamination.
No information available.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under normal conditions.
None known, based on information available
Hazardous polymerization does not occur. None under normal processing.
Incompatible products. Excess heat. Keep away from open flames, hot surfaces and sources of ignition.
Strong oxidizing agents.
Carbon monoxide (CO). Carbon dioxide (CO₂).
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- UN2252
- Shipping Name
- 1,2-DIMETHOXYETHANE
- Transport Class
- 3
- Packing Group
- II
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What other names is Ethylene glycol dimethyl ether known by?
Ethylene glycol dimethyl ether is also known as: Monoglyme; 1,2-Dimethoxyethane
What is the hazard signal word for Ethylene glycol dimethyl ether?
The signal word is danger.
What is the physical form of Ethylene glycol dimethyl ether?
Ethylene glycol dimethyl ether is a liquid appearing as colorless . It has petroleum distillates odor.
What is Ethylene glycol dimethyl ether used for?
Laboratory chemicals. Sector of use: SU3 - Industrial uses: Uses of substances as such or in preparations at industrial sites; Product category: PC21 - Laboratory chemicals; Process categories: PROC15 - Use as a laboratory reagent; Environmental release category: ERC6a - Industrial use resulting in manufacture of another substance (use of intermediates)
What are the hazard statements for Ethylene glycol dimethyl ether?
This substance has 4 hazard statements:
- H225: Highly flammable liquid and vapor
- H315: Causes skin irritation
- H332: Harmful if inhaled
- H360FD: May damage fertility. May damage the unborn child
What is the melting point of Ethylene glycol dimethyl ether?
The melting point is -69 °C / -92.2 °F and the boiling point is 84 - 86 °C / 183.2 - 186.8 °F.