NextSDS Logo
Et

Ethylene glycol dimethacrylate

WARNING Liquid SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
Ethylene glycol dimethacrylate
Product Code
44151
Chemical Name
Ethylene glycol dimethacrylate

Regulatory Identifiers

CAS Number

Chemical Abstracts Service registry number - unique identifier for chemical substances

EC Number

European Community number - used for regulatory compliance in EU/EEA

Uses Information

Identified Uses
SU24 Scientific research and development

Overview

Ethylene glycol dimethacrylate (CAS: 97-90-5 ) is a not determined substance commonly used su24 scientific research and development.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

warning (Warning)

Hazard Classifications

Skin Sens. Category 1 H317
STOT SE Category 3 H335

GHS Hazard Pictograms & Safety Symbols

GHS07 GHS Hazard Pictogram: Health hazard warning - Materials harmful to health including irritants and sensitizers

GHS07

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H317: May cause an allergic skin reaction.
  • H335: May cause respiratory irritation.

Precautionary Statements

  • P261: Avoid breathing dust/fume/gas/mist/vapors/spray
  • P280: Wear protective gloves.
  • P304+P340: IF INHALED: Remove person to fresh air and keep comfortable for breathing.
  • P312: Call a POISON CENTER/doctor if you feel unwell.
  • P405: Store locked up.
  • P501: Dispose of contents/container in accordance with local/regional/national/international regulations.

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

Alfa Aesar Thermo Fisher Scientific Chemicals, Inc. company logo - Safety Data Sheet supplier organization

Alfa Aesar Thermo Fisher Scientific Chemicals, Inc.

manufacturer

๐Ÿ“

30 Bond Street, Ward Hill, MA 01835-8099

๐ŸŒ

US

๐Ÿ“ž

800-343-0660

๐Ÿ“ 

800-322-4757

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Emergency Contact

๐Ÿ“ž

800-343-0660

๐Ÿ•’

Monday-Friday, 8am-7pm EST

Carechem 24

๐Ÿ“ž

866-928-0789

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

substance

General Composition

Substances

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Ethylene glycol dimethacrylate
EC: 202-617-2
97-90-5 100% โœ“ Non-hazardous

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

Supply fresh air. If required, provide artificial respiration. Keep patient warm.

๐Ÿ–๏ธ Skin Contact

Immediately wash with water and soap and rinse thoroughly.

๐Ÿ‘๏ธ Eye Contact

Rinse opened eye for several minutes under running water. Then consult a doctor.

๐Ÿฝ๏ธ Ingestion/Swallowing

Seek medical treatment.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿ“Š Form
Not available
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ”ฅ Flammability
Not determined.
๐ŸงŠ Melting Point
Not determined
Critical Property
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Properties Status
Not available
๐ŸŽจ Colour
Not available
๐Ÿ”ฅ Flash Point
>110 ยฐC (>230 ยฐF)
Critical Property
๐Ÿ“Š Auto Ignition Temperature
Not determined.
๐Ÿ“Š Bulk Density
Not available
๐Ÿ“Š Relative Density
Not determined.
๐Ÿ“Š Freezing Point
Not available
๐Ÿ’จ Boiling Point
83-85 โ„ƒ (181-185 ยฐF) (1mm)
Critical Property
๐Ÿ“Š Odor Threshold
Not determined.
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ’จ Evaporation Rate
Not determined.
๐Ÿ“Š Partition Coefficient
Not determined.
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Lower Explosive Limit
Not determined
๐Ÿ“Š Upper Explosive Limit
Not determined
โš–๏ธ Density
1.051 g/cm3 (8.771 lbs/gal)
Critical Property
๐Ÿ“Š Solubility In Water
Not determined
๐Ÿ“Š Vapor Density
Not determined.
๐Ÿ“Š Cloud Point
Not available
๐Ÿงช Physical State
Liquid
Critical Property
๐Ÿ“Š Softening Point
Not available
๐Ÿงช Ph
Not determined.
๐Ÿ‘๏ธ Appearance
Not determined
๐Ÿ’ง Solubility
Not determined
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Decomposition Temperature
Not determined
๐Ÿ“Š Dynamic Viscosity
Not determined.
๐Ÿ’จ Vapor Pressure
Not determined
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Kinematic Viscosity
Not determined.
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ‘ƒ Odor
Not determined
๐Ÿ“Š Physical State Data
liquid
๐Ÿ“Š Voc Content
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿญ Engineering Controls

Properly operating chemical fume hood designed for hazardous chemicals and having an average face velocity of at least 100 feet per minute.

๐Ÿงค Hand Protection

Impervious gloves. Check protective gloves prior to each use for their proper condition. The selection of suitable gloves not only depends on the material, but also on quality. Quality will vary from manufacturer to manufacturer. Penetration time of glove material (in minutes) Not determined

๐Ÿ‘๏ธ Eye Protection

Safety glasses with side shields / NIOSH (US) or EN 166(EU)

๐Ÿ˜ท Respiratory Protection

Use suitable respirator when high concentrations are present. Recommended filter device for short term use: Use a respirator with multi-purpose combination (US) or type ABEK (EN 14387) as a backup to engineering controls. Risk assessment should be performed to determine if air-purifying respirators are appropriate. Only use equipment tested and approved under appropriate government standards such as NIOSH (USA) or CEN (EU).

๐Ÿฆบ Skin/Body Protection

Protective work clothing.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

๐Ÿ“ฆ Proper Shipping Name

Not applicable

โš ๏ธ Transport Hazard Class

Not applicable

๐Ÿ“‹ Packing Group

Not applicable

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for Ethylene glycol dimethacrylate?

The signal word for this substance is "warning".

What is the physical form of Ethylene glycol dimethacrylate?

Ethylene glycol dimethacrylate is a liquid appearing as not determined . It has not determined odor.

What is the solubility of Ethylene glycol dimethacrylate?

Not determined

What is Ethylene glycol dimethacrylate used for?

SU24 Scientific research and development

What are the hazard statements for Ethylene glycol dimethacrylate?

This substance has 2 hazard statements: H317: May cause an allergic skin reaction. H335: May cause respiratory irritation.

What is the melting point of Ethylene glycol dimethacrylate?

The melting point is Not determined and the boiling point is 83-85 โ„ƒ (181-185 ยฐF) (1mm).