NextSDS Logo
Safety Data Sheet EN

Ethylene glycol dimethacrylate

CAS 97-90-5
EC 202-617-2

Keep this SDS organized and up to date

Add this SDS to your NextSDS library and keep all its safety information in one place.

Add to my SDS library for free
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Ethylene glycol dimethacrylate
Product Code
44151

Regulatory Identifiers

CAS Number
97-90-5 Check regulations →
EC Number
202-617-2 Check regulations →

Identified Uses

SU24 Scientific research and development

Manufacturers & Suppliers

Alfa Aesar, Thermo Fisher Scientific Chemicals, Inc. logo

Alfa Aesar, Thermo Fisher Scientific Chemicals, Inc.

manufacturer

30 Bond Street, Ward Hill, MA 01835-8099

800-343-0660

http://www.alfa.com

Emergency Contacts

Emergency Contact

(800) 343-0660

Monday-Friday, 8am-7pm EST

Carechem 24

(866) 928-0789

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified warning

Hazard Classifications

Skin Sens. Cat. 1 H317
STOT SE Cat. 3 H335

GHS Pictograms

GHS07 - Health hazard

GHS07

Hazard Statements

H317 May cause an allergic skin reaction.
H335 May cause respiratory irritation.

Precautionary Statements

P261 Avoid breathing dust/fume/gas/mist/vapors/spray
P280 Wear protective gloves.
P304 + P340 IF INHALED: Remove person to fresh air and keep comfortable for breathing.
P312 Call a POISON CENTER/doctor if you feel unwell.
P405 Store locked up.
P501 Dispose of contents/container in accordance with local/regional/national/international regulations.

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type substance

Substances

Chemical Name CAS Number Concentration Hazardous
Ethylene glycol dimethacrylate EC: 202-617-2 97-90-5 100% No
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Supply fresh air. If required, provide artificial respiration. Keep patient warm.

Skin contact

Immediately wash with water and soap and rinse thoroughly.

Eye contact

Rinse opened eye for several minutes under running water. Then consult a doctor.

Ingestion

Seek medical treatment.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Carbon dioxide, extinguishing powder or water spray. Fight larger fires with water spray or alcohol resistant foam.

Specific hazards

If this product is involved in a fire, the following can be released: Carbon monoxide and carbon dioxide

Firefighter Protection

Wear self-contained respirator. Wear fully protective impervious suit.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Wear protective equipment. Keep unprotected persons away.

Environmental

Do not allow product to reach sewage system or any water course.

Cleanup methods

Absorb with liquid-binding material

Materials: sand, diatomite, acid binders, universal binders, sawdust

—

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Keep container tightly sealed.

Storage

Refrigerate, keep container tightly sealed.

Fire prevention

No information known.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Properly operating chemical fume hood designed for hazardous chemicals and having an average face velocity of at least 100 feet per minute.

Hands

Impervious gloves. Check protective gloves prior to each use for their proper condition. The selection of suitable gloves not only depends on the material, but also on quality. Quality will vary from manufacturer to manufacturer. Penetration time of glove material (in minutes) Not determined

Eyes

Safety glasses with side shields / NIOSH (US) or EN 166(EU)

Respiratory

Use suitable respirator when high concentrations are present. Recommended filter device for short term use: Use a respirator with multi-purpose combination (US) or type ABEK (EN 14387) as a backup to engineering controls. Risk assessment should be performed to determine if air-purifying respirators are appropriate. Only use equipment tested and approved under appropriate government standards such as NIOSH (USA) or CEN (EU).

Skin/Body

Protective work clothing.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Language Code
---
Physical State
Liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
Not determined
Colour
---
Colour Intensity
---
Form
---
Odor
Not determined
Odor Threshold
Not determined.
Ph
Not determined.
Melting Point
Not determined
Boiling Point
83-85 ℃ (181-185 °F) (1mm)
Flash Point
>110 °C (>230 °F)
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
Not determined.
Vapor Pressure
Not determined
Vapor Density
Not determined.
Relative Density
Not determined.
Bulk Density
---
Density
1.051 g/cm3 (8.771 lbs/gal)
Flammability
Not determined.
Upper Explosive Limit
Not determined
Lower Explosive Limit
Not determined
Explosive Limits
---
Auto Ignition Temperature
Not determined.
Decomposition Temperature
Not determined
Solubility
Not determined
Partition Coefficient
Not determined.
Solubility In Water
Not determined
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
Not determined.
Kinematic Viscosity
Not determined.
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

The data for this section has not been processed yet.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

Toxicity

Aquatic toxicity: No further relevant information available.

No further relevant information available regarding aquatic toxicity.

Persistence and degradability

No further relevant information available.

No further relevant information available.

Bioaccumulative potential

No further relevant information available.

No further relevant information available.

12.4 Mobility in soil

No further relevant information available.

No further relevant information available.

Results of PBT and vPvB assessment

- PBT: Not applicable. - vPvB: Not applicable.

The substance is not considered to be PBT or vPvB.

Other adverse effects

No further relevant information available.

No further relevant information available.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

Shipping Name
Not applicable
Transport Class
Not applicable
Packing Group
Not applicable
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The product is classified and labeled in accordance with 29 CFR 1910 (OSHA HCS)

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Ethylene glycol dimethacrylate?

The signal word is warning.

What is the physical form of Ethylene glycol dimethacrylate?

Ethylene glycol dimethacrylate is a liquid appearing as not determined . It has not determined odor.

What is the solubility of Ethylene glycol dimethacrylate?

Not determined

What is Ethylene glycol dimethacrylate used for?

SU24 Scientific research and development

What are the hazard statements for Ethylene glycol dimethacrylate?

This substance has 2 hazard statements:

  • H317: May cause an allergic skin reaction.
  • H335: May cause respiratory irritation.

What is the melting point of Ethylene glycol dimethacrylate?

The melting point is Not determined and the boiling point is 83-85 ℃ (181-185 °F) (1mm).