NextSDS Logo
Safety Data Sheet EN

1-Pentene

CAS 109-67-1

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
1-Pentene
Product Code
430730000; 430731000
Chemical Name
1-Pentene
Synonyms
Propylethylene; alfa-n-Amylene

Regulatory Identifiers

CAS Number
109-67-1 Check regulations →
REACH No.
01-2119487483-28

Identified Uses

Laboratory chemicals. Sector of use: SU3 - Industrial uses: Uses of substances as such or in preparations at industrial sites; Product category: PC21 - Laboratory chemicals; Process categories: PROC15 - Use as a laboratory reagent; Environmental release category: ERC6a - Industrial use resulting in manufacture of another substance (use of intermediates)

Uses advised against

No Information available

Manufacturers & Suppliers

T

Thermo Fisher Scientific

manufacturer

Janssen Pharmaceuticalaan 3a, 2440 Geel, Belgium

F

Fisher Scientific UK

distributor

Bishop Meadow Road, Loughborough, Leicestershire LE11 5RG, United Kingdom

F

Fisher Scientific AG

distributor

Neuhofstrasse 11, CH 4153 Reinach

+41 (0) 56 618 41 11

Emergency Contacts

For information US

001-800-227-6701

Europe

+32 14 57 52 11

Emergency Number: US

001-201-796-7100

Emergency Number: Europe

+32 14 57 52 99

CHEMTREC

001-800-424-9300

CHEMTREC

001-703-527-3887

Tox Info Suisse

145

24hr

Tox Info Suisse

+41-44 251 51 51

Chemtrec

0800 564 402

24h

Chemtrec

+41-43 508 20 11

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Flam. Liq. Cat. 1 H224
Asp. Tox. Cat. 1 H304
Aquatic Chronic Cat. 3 H412

GHS Pictograms

GHS02 - Flammable

GHS02

GHS08 - Serious health hazard

GHS08

Hazard Statements

H224 Extremely flammable liquid and vapor
H304 May be fatal if swallowed and enters airways
H412 Harmful to aquatic life with long lasting effects

Precautionary Statements

P210 Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking
P240 Ground and bond container and receiving equipment
P243 Take action to prevent static discharges
P273 Avoid release to the environment
P301 + P310 IF SWALLOWED: Immediately call a POISON CENTER or doctor/physician
P331 Do NOT induce vomiting
P403 + P235 Store in a well-ventilated place. Keep cool

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type substance
Chemical Name CAS Number Concentration Hazardous
1-Pentene EC: 203-694-5 109-67-1 95% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove to fresh air. Do not use mouth-to-mouth method if victim ingested or inhaled the substance; give artificial respiration with the aid of a pocket mask equipped with a one-way valve or other proper respiratory medical device. Get medical attention. If not breathing, give artificial respiration.

Symptoms: Difficulty in breathing. Inhalation of high vapor concentrations may cause symptoms like headache, dizziness, tiredness, nausea and vomiting. Risk of serious damage to the lungs (by aspiration).

Skin contact

Wash off immediately with plenty of water for at least 15 minutes. Get medical attention if symptoms occur.

Eye contact

Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. Get medical attention.

Ingestion

Aspiration hazard. Do NOT induce vomiting. Call a physician or poison control center immediately. If vomiting occurs naturally, have victim lean forward.

Immediate Medical Attention

Get medical attention.

Medical Treatment

Treat symptomatically.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Water spray, carbon dioxide (CO2), dry chemical, alcohol-resistant foam. Water mist may be used to cool closed containers.

Unsuitable media

Do not use a solid water stream as it may scatter and spread fire.

Specific hazards

Extremely flammable. Risk of ignition. Vapors may form explosive mixtures with air. Vapors may travel to source of ignition and flash back. Containers may explode when heated. Thermal decomposition can lead to release of irritating gases and vapors. Keep product and empty container away from heat and sources of ignition.

Instructions

As in any fire, wear self-contained breathing apparatus pressure-demand, MSHA/NIOSH (approved or equivalent) and full protective gear.

Firefighter Protection

As in any fire, wear self-contained breathing apparatus pressure-demand, MSHA/NIOSH (approved or equivalent) and full protective gear.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Use personal protective equipment as required. Avoid contact with skin, eyes or clothing.

Environmental

Avoid release to the environment. Do not flush into surface water or sanitary sewer system.

Cleanup methods

Soak up with inert absorbent material. Keep in suitable, closed containers for disposal. Use spark-proof tools and explosion-proof equipment.

Materials: inert absorbent material

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Wear personal protective equipment/face protection. Use spark-proof tools and explosion-proof equipment. Keep away from open flames, hot surfaces and sources of ignition. Take precautionary measures against static discharges. Avoid contact with skin, eyes or clothing. Avoid ingestion and inhalation. Use only non-sparking tools. Use spark-proof tools and explosion-proof equipment. To avoid ignition of vapors by static electricity discharge, all metal parts of the equipment must be grounded.

Storage

Keep container tightly closed in a dry and well-ventilated place. Keep away from heat, sparks and flame. Keep refrigerated. Flammables area.

Hygiene

Handle in accordance with good industrial hygiene and safety practice. Keep away from food, drink and animal feeding stuffs. Do not eat, drink or smoke when using this product. Remove and wash contaminated clothing and gloves, including the inside, before re-use. Wash hands before breaks and after work.

Fire prevention

Keep away from open flames, hot surfaces and sources of ignition. Take precautionary measures against static discharges. Keep away from heat, sparks and flame.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Ensure adequate ventilation, especially in confined areas. Use explosion-proof electrical/ventilating/lighting/equipment. Ensure that eyewash stations and safety showers are close to the workstation location. Wherever possible, engineering control measures such as the isolation or enclosure of the process, the introduction of process or equipment changes to minimise release or contact, and the use of properly designed ventilation systems, should be adopted to control hazardous materials at source

Hands

Protective gloves. Glove material: Nitrile rubber, Viton (R). Breakthrough time: See manufacturers recommendations. EU standard: EN 374. Glove comments: (minimum requirement)

Eyes

Wear safety glasses with side shields (or goggles) (European standard - EN 166)

Respiratory

When workers are facing concentrations above the exposure limit they must use appropriate certified respirators. To protect the wearer, respiratory protective equipment must be the correct fit and be used and maintained properly. Large scale/emergency use: Use a NIOSH/MSHA or European Standard EN 136 approved respirator if exposure limits are exceeded or if irritation or other symptoms are experienced. Recommended Filter type: low boiling organic solvent Type AX Brown conforming to EN371. Small scale/Laboratory use: Use a NIOSH/MSHA or European Standard EN 149:2001 approved respirator if exposure limits are exceeded or if irritation or other symptoms are experienced. Recommended half mask: Valve filtering: EN405; or; Half mask: EN140; plus filter, EN 141. When RPE is used a face piece Fit Test should be conducted

Skin/Body

Wear appropriate protective gloves and clothing to prevent skin exposure. Inspect gloves before use. observe the instructions regarding permeability and breakthrough time which are provided by the supplier of the gloves. (Refer to manufacturer/supplier for information) gloves are suitable for the task: Chemical compatibility, Dexterity, Operational conditions, User susceptibility, e.g. sensitisation effects, also take into consideration the specific local conditions under which the product is used, such as the danger of cuts, abrasion. gloves with care avoiding skin contamination.

Environmental

Prevent product from entering drains.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Vapor Pressure
700 mbar @ 20 °C
Colour Intensity
---
Physical State
Liquid
Odor Threshold
No data available
Form
---
Melting Point
-165 °C / -265 °F
Odor
No information available
Voc Content
---
Colour
---
Physical State Data
liquid
Partition Coefficient
2.66
Solidification Point
---
Explosive Limits
---
Crystallisation Point
---
Bulk Density
Not applicable
Solubility
---
Decomposition Temperature
No data available
Properties Status
---
Cloud Point
---
Relative Evaporation Rate
---
Upper Explosive Limit
---
Dynamic Viscosity
0.202 mPa.s (20°C)
Freezing Point
---
Softening Point
No data available
Vapor Density
---
Lower Explosive Limit
1.4 Vol%
Solubility In Water
0.15 G/L (20°C)
Appearance
Colorless
Auto Ignition Temperature
273 °C / 523.4 °F
Evaporation Rate
---
Metal Corrosion
---
Kinematic Viscosity
---
Flash Point
-28 °C / -18.4 °F
Boiling Point
30 °C / 86 °F
Relative Density
0.640
Solubility In Fat
---
Flammability
Extremely flammable
Molecular Weight
70.13
State Under Standard Conditions
---
Ph
No information available
Density
0.640
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under normal conditions.

Reactivity

None known, based on information available

Hazardous reactions

Hazardous Polymerization: Hazardous polymerization does not occur. Hazardous Reactions: None under normal processing.

Avoid

Incompatible products. Excess heat. Keep away from open flames, hot surfaces and sources of ignition.

Incompatible

Strong oxidizing agents. Strong acids. Strong bases.

Decomposition

Carbon monoxide (CO). Carbon dioxide (CO₂).

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
1108
Shipping Name
1-PENTENE
Transport Class
3
Packing Group
I
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What other names is 1-Pentene known by?

1-Pentene is also known as: Propylethylene; alfa-n-Amylene

What is the hazard signal word for 1-Pentene?

The signal word is danger.

What is the physical form of 1-Pentene?

1-Pentene is a liquid appearing as colorless . It has no information available odor.

What is 1-Pentene used for?

Laboratory chemicals. Sector of use: SU3 - Industrial uses: Uses of substances as such or in preparations at industrial sites; Product category: PC21 - Laboratory chemicals; Process categories: PROC15 - Use as a laboratory reagent; Environmental release category: ERC6a - Industrial use resulting in manufacture of another substance (use of intermediates)

What are the hazard statements for 1-Pentene?

This substance has 3 hazard statements:

  • H224: Extremely flammable liquid and vapor
  • H304: May be fatal if swallowed and enters airways
  • H412: Harmful to aquatic life with long lasting effects

What is the melting point of 1-Pentene?