Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
MOTIP POWER BRAKE CLEANER 500 ML
Product Code
090563

Regulatory Identifiers

CAS Number
N/A

Identified Uses

SU21 Consumer uses: Private households / general public / consumers; SU22 Professional uses: Public domain (administration, education, entertainment, services, craftsmen); PROC7 Industrial spraying; PROC11 Non industrial spraying; Cleaning agent/ Cleaner

Uses advised against

No further relevant information available.

Manufacturers & Suppliers

E

European Aerosols B.V.

manufacturer

Wolframweg 2, NL-8471 XC Wolvega, The Netherlands

+31 (0)561 694400

Emergency Contacts

Emergency Contact

+31 (0)561-694400

09:00h - 17:00h

NPIS National Poisons Information Centre

+44 0344 892 0111

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Aerosol Cat. 1 H222
Aquatic Chronic Cat. 2 H411
Skin Irrit. Cat. 2 H315
STOT SE Cat. 3 H336

GHS Pictograms

GHS02 - Flammable

GHS02

GHS07 - Health hazard

GHS07

GHS09 - Environmental hazard

GHS09

Hazard Statements

H222 Extremely flammable aerosol. Pressurised container: May burst if heated.
H315 Causes skin irritation.
H336 May cause drowsiness or dizziness.
H411 Toxic to aquatic life with long lasting effects.

Precautionary Statements

P101 If medical advice is needed, have product container or label at hand.
P102 Keep out of reach of children.
P210 Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
P211 Do not spray on an open flame or other ignition source.
P251 Do not pierce or burn, even after use.
P260 Do not breathe spray.
P264 Wash contaminated body parts thoroughly after handling.
P271 Use only outdoors or in a well-ventilated area.
P273 Avoid release to the environment.
P280 Wear protective gloves / eye protection.
P302 + P352 IF ON SKIN: Wash with plenty of water.
P312 Call a POISON CENTER/doctor if you feel unwell.
P332 + P313 If skin irritation occurs: Get medical advice/attention.
P410 + P412 Protect from sunlight. Do not expose to temperatures exceeding 50 °C/122 °F.
P501 Dispose of contents / container in accordance with regional regulations.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Hydrocarbons, C6-C7, n-alkanes, isoalkanes, cyclics, <5% n-hexane EC: 921-024-6 --- 75 - 100% Yes
carbon dioxide EC: 204-696-9 124-38-9 2.5 - 5% Yes

The content of Benzene (EINECS-Nr. 200-753-7) in the ingredients is less than 0,1% (Note P Annex 1A 1272/2008 EU), so the classification as carcinogen need not to apply.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

In case of unconsciousness place patient stably in side position for transportation.

Skin contact

Immediately wash with water and soap and rinse thoroughly.

Eye contact

Rinse opened eye for several minutes under running water.

Ingestion

Drink plenty of water and provide fresh air. Call for a doctor immediately.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

CO2, powder or water spray. Fight larger fires with water spray or alcohol resistant foam.

Specific hazards

During heating or in case of fire poisonous gases are produced.

Firefighter Protection

Mouth respiratory protective device.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Mount respiratory protective device. Wear protective equipment. Keep unprotected persons away. Keep away from ignition sources.

Environmental

Do not allow product to reach sewage system or any water course. Do not allow to enter sewers/ surface or ground water.

Cleanup methods

Dispose contaminated material as waste according to item 13.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Ensure good ventilation/exhaustion at the workplace. Keep respiratory protective device available. Do not spray onto a naked flame or any incandescent material. Keep ignition sources away - Do not smoke. Pressurised container: protect from sunlight and do not expose to temperatures exceeding 50°C, i.e. electric lights. Do not pierce or burn, even after use.

Storage

Observe official regulations on storing packagings with pressurised containers. Keep container tightly sealed.

Fire prevention

Do not spray onto a naked flame or any incandescent material. Keep ignition sources away - Do not smoke.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

No further data; see item 7.

Hands

Protective gloves. Material of gloves: Butyl rubber, BR. The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer. Penetration time of glove material: Butyl rubber gloves with a thickness of 0.4 mm are resistant to: Acetone: 480 min, Butyl acetate: 60 min, Ethyl acetate: 170 min, Xylene: 42 min. Butyl rubber gloves with a thickness of 0.4 mm are solvent resistant for 42-480 minutes. As protective measure, we recommend that users and responsible persons for work safety assume solvent resistance length of 42 minutes. Considering the data in section 3 of this SDS, one can assume longer resistance length in particular cases.

Eyes

Not required.

Respiratory

In case of brief exposure or low pollution use respiratory filter device. In case of intensive or longer exposure use self-contained respiratory protective device. Filter A2/P3

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Aerosol
Melting Point
<-25 °C (<-13 °F)
Kinematic Viscosity
Not determined.
Ph
---
Flammability
---
Vapor Pressure
5500 hPa (4125.3 mm Hg)
Auto Ignition Temperature
>200 °C (>392 °F)
Partition Coefficient
---
Solubility In Water
Not miscible or difficult to mix.
Upper Explosive Limit
8 Vol %
Lower Explosive Limit
0.6 Vol %
Solubility
---
Properties Status
---
Cloud Point
---
Freezing Point
<-25 °C (<-13 °F)
Form
---
Colour
Clear
Boiling Point
Not applicable, as aerosol.
Vapor Density
---
Odor
Solvent-like
Flash Point
-12 °C (10.4 °F)
Appearance
Aerosol
Relative Density
---
Odor Threshold
Not determined.
Molecular Weight
---
Solubility In Fat
---
Relative Evaporation Rate
---
Solidification Point
---
Softening Point
---
Bulk Density
---
Voc Content
97.00 %
Explosive Limits
---
Density
0.7 g/cm³ (5.8 lbs/gal)
Metal Corrosion
---
Dynamic Viscosity
Not determined.
State Under Standard Conditions
---
Crystallisation Point
---
Decomposition Temperature
Not determined.
Colour Intensity
---
Evaporation Rate
Not applicable.
Physical State Data
aerosol
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

No decomposition if used according to specifications.

Reactivity

No further relevant information available.

Hazardous reactions

No dangerous reactions known.

Avoid

No further relevant information available.

Incompatible

No further relevant information available.

Decomposition

No dangerous decomposition products known.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
1950
Shipping Name
AEROSOLS
Transport Class
2.1
ADR

Warning: Gases.

IMDG

Warning: Gases. SW1 Protected from sources of heat. SW22 For AEROSOLS with a maximum capacity of 1 litre: Category A. For AEROSOLS with a capacity above 1 litre: Category B. For WASTE AEROSOLS: Category C, Clear of living quarters. SG69 For AEROSOLS with a maximum capacity of 1 litre: Segregation as for class 9. Stow 'separated from' class 1 except for division 1.4. For AEROSOLS with a capacity above 1 litre: Segregation as for the appropriate subdivision of class 2. For WASTE AEROSOLS: Segregation as for the appropriate subdivision of class 2.

IATA

Warning: Gases.

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for MOTIP POWER BRAKE CLEANER 500 ML?

The signal word is danger.

What is the physical form of MOTIP POWER BRAKE CLEANER 500 ML?

MOTIP POWER BRAKE CLEANER 500 ML is a aerosol appearing as aerosol with clear color. It has solvent-like odor.

What is MOTIP POWER BRAKE CLEANER 500 ML used for?

SU21 Consumer uses: Private households / general public / consumers; SU22 Professional uses: Public domain (administration, education, entertainment, services, craftsmen); PROC7 Industrial spraying; PROC11 Non industrial spraying; Cleaning agent/ Cleaner

What are the hazard statements for MOTIP POWER BRAKE CLEANER 500 ML?

This substance has 4 hazard statements:

  • H222: Extremely flammable aerosol. Pressurised container: May burst if heated.
  • H315: Causes skin irritation.
  • H336: May cause drowsiness or dizziness.
  • H411: Toxic to aquatic life with long lasting effects.

What is the melting point of MOTIP POWER BRAKE CLEANER 500 ML?

The melting point is <-25 °C (<-13 °F) and the boiling point is Not applicable, as aerosol..