NextSDS Logo
Safety Data Sheet EN

Palmitic acid

CAS 57-10-3
EC 200-312-9

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Palmitic acid
Product Code
P/0280/53, P/0280NC/53
Chemical Name
Palmitic acid
Synonyms
Hexadecanoic acid

Regulatory Identifiers

CAS Number
57-10-3 Check regulations →
EC Number
200-312-9 Check regulations →

Identified Uses

Laboratory chemicals. Sector of use: SU3 - Industrial uses: Uses of substances as such or in preparations at industrial sites. Product category: PC21 - Laboratory chemicals. Process categories: PROC15 - Use as a laboratory reagent. Environmental release category: ERC6a - Industrial use resulting in manufacture of another substance (use of intermediates)

Uses advised against

No Information available

Manufacturers & Suppliers

F

Fisher Scientific UK

distributor

Bishop Meadow Road, Loughborough, Leicestershire LE11 5RG, United Kingdom

A

Acros Organics BVBA

distributor

Janssen Pharmaceuticalaan 3a, 2440 Geel, Belgium

Emergency Contacts

Fisher Scientific UK

01509 231166

Chemtrec US

(800) 424-9300

Chemtrec EU

001 (202) 483-7616

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type substance
Chemical Name CAS Number Concentration Hazardous
Palmitic acid EC: 200-312-9 57-10-3 95% No
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove from exposure, lie down. Remove to fresh air. Get medical attention. If not breathing, give artificial respiration.

Skin contact

Wash off immediately with plenty of water for at least 15 minutes. Get medical attention.

Eye contact

Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. Get medical attention.

Ingestion

Do NOT induce vomiting. Get medical attention.

Immediate Medical Attention

Get medical attention.

Medical Treatment

Treat symptomatically.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Water spray. Carbon dioxide (CO₂). Dry chemical. Chemical foam.

Unsuitable media

No information available.

Specific hazards

Thermal decomposition can lead to release of irritating gases and vapors. Keep product and empty container away from heat and sources of ignition.

Instructions

As in any fire, wear self-contained breathing apparatus pressure-demand, MSHA/NIOSH (approved or equivalent) and full protective gear.

Firefighter Protection

As in any fire, wear self-contained breathing apparatus pressure-demand, MSHA/NIOSH (approved or equivalent) and full protective gear.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Environmental

Do not let this chemical enter the environment.

Cleanup methods

Sweep up and shovel into suitable containers for disposal.

Materials: suitable containers

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Wear personal protective equipment/face protection. Ensure adequate ventilation. Avoid contact with skin and eyes. Do not breathe dust. Do not breathe mist/vapors/spray. Do not ingest. If swallowed then seek immediate medical assistance.

Storage

Keep in a dry, cool and well-ventilated place. Keep container tightly closed.

Hygiene

Handle in accordance with good industrial hygiene and safety practice. Keep away from food, drink and animal feeding stuffs. Do not eat, drink or smoke when using this product. Remove and wash contaminated clothing and gloves, including the inside, before re-use. Wash hands before breaks and after work.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Ensure adequate ventilation, especially in confined areas. Ensure that eyewash stations and safety showers are close to the workstation location. Wherever possible, engineering control measures such as the isolation or enclosure of the process, the introduction of process or equipment changes to minimise release or contact, and the use of properly designed ventilation systems, should be adopted to control hazardous materials at source

Hands

Protective gloves. Glove material: Natural rubber, Nitrile rubber, Neoprene, PVC. Breakthrough time: See manufacturers recommendations. EU standard: EN 374. Glove comments: (minimum requirement). Inspect gloves before use. Please observe the instructions regarding permeability and breakthrough time which are provided by the supplier of the gloves. (Refer to manufacturer/supplier for information) Ensure gloves are suitable for the task: Chemical compatibility, Dexterity, Operational conditions, User susceptibility, e.g. sensitisation effects, also take into consideration the specific local conditions under which the product is used, such as the danger of cuts, abrasion. Remove gloves with care avoiding skin contamination.

Eyes

Goggles (European standard - EN 166)

Respiratory

When workers are facing concentrations above the exposure limit they must use appropriate certified respirators. To protect the wearer, respiratory protective equipment must be the correct fit and be used and maintained properly. Large scale/emergency use: Use a NIOSH/MSHA or European Standard EN 136 approved respirator if exposure limits are exceeded or if irritation or other symptoms are experienced Recommended Filter type: Particulates filter conforming to EN 143. Small scale/Laboratory use: Use a NIOSH/MSHA or European Standard EN 149:2001 approved respirator if exposure limits are exceeded or if irritation or other symptoms are experienced. Recommended half mask:- Particle filtering: EN149:2001 When RPE is used a face piece Fit Test should be conducted

Skin/Body

Wear appropriate protective gloves and clothing to prevent skin exposure

Environmental

No information available.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Softening Point
No data available
Solubility
---
Relative Evaporation Rate
---
Odor Threshold
No data available
Kinematic Viscosity
---
Colour Intensity
---
Voc Content
---
State Under Standard Conditions
---
Form
---
Flash Point
206 °C / 402.8 °F
Lower Explosive Limit
---
Melting Point
59 - 63 °C / 138.2 - 145.4 °F
Density
---
Solubility In Fat
---
Freezing Point
---
Dynamic Viscosity
---
Explosive Limits
---
Appearance
White
Metal Corrosion
---
Cloud Point
---
Relative Density
---
Vapor Density
Not applicable Solid
Odor
No information available
Solidification Point
---
Ph
No information available
Colour
---
Auto Ignition Temperature
No data available
Molecular Weight
256.42
Solubility In Water
Insoluble
Physical State
Solid
Evaporation Rate
Not applicable - Solid
Flammability
---
Partition Coefficient
7.17
Boiling Point
351.5 °C / 664.7 °F
Vapor Pressure
No data available
Physical State Data
solid
Decomposition Temperature
No data available
Upper Explosive Limit
---
Properties Status
---
Bulk Density
---
Crystallisation Point
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under normal conditions.

Reactivity

None known, based on information available

Hazardous reactions

Hazardous Polymerization: No information available. Hazardous Reactions: No information available.

Avoid

Heat, flames and sparks. Exposure to light. Incompatible products.

Incompatible

Bases. Reducing Agent.

Decomposition

Carbon monoxide (CO). Carbon dioxide (CO₂).

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What other names is Palmitic acid known by?

Palmitic acid is also known as: Hexadecanoic acid

What is the hazard signal word for Palmitic acid?

The signal word is no signal word.

What is the physical form of Palmitic acid?

Palmitic acid is a solid appearing as white . It has no information available odor.

What is Palmitic acid used for?

Laboratory chemicals. Sector of use: SU3 - Industrial uses: Uses of substances as such or in preparations at industrial sites. Product category: PC21 - Laboratory chemicals. Process categories: PROC15 - Use as a laboratory reagent. Environmental release category: ERC6a - Industrial use resulting in manufacture of another substance (use of intermediates)

What is the melting point of Palmitic acid?

The melting point is 59 - 63 °C / 138.2 - 145.4 °F and the boiling point is 351.5 °C / 664.7 °F.