Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Palmitic acid
- Product Code
- P/0280/53, P/0280NC/53
- Chemical Name
- Palmitic acid
- Synonyms
- Hexadecanoic acid
Regulatory Identifiers
- CAS Number
- 57-10-3 Check regulations →
- EC Number
- 200-312-9 Check regulations →
Identified Uses
Laboratory chemicals. Sector of use: SU3 - Industrial uses: Uses of substances as such or in preparations at industrial sites. Product category: PC21 - Laboratory chemicals. Process categories: PROC15 - Use as a laboratory reagent. Environmental release category: ERC6a - Industrial use resulting in manufacture of another substance (use of intermediates)
Uses advised against
No Information available
Manufacturers & Suppliers
Fisher Scientific UK
distributor
Bishop Meadow Road, Loughborough, Leicestershire LE11 5RG, United Kingdom
Acros Organics BVBA
distributor
Janssen Pharmaceuticalaan 3a, 2440 Geel, Belgium
Emergency Contacts
Fisher Scientific UK
01509 231166
Chemtrec US
(800) 424-9300
Chemtrec EU
001 (202) 483-7616
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Palmitic acid EC: 200-312-9 | 57-10-3 | 95% | No |
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove from exposure, lie down. Remove to fresh air. Get medical attention. If not breathing, give artificial respiration.
Wash off immediately with plenty of water for at least 15 minutes. Get medical attention.
Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. Get medical attention.
Do NOT induce vomiting. Get medical attention.
Immediate Medical Attention
Get medical attention.
Medical Treatment
Treat symptomatically.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Water spray. Carbon dioxide (CO₂). Dry chemical. Chemical foam.
No information available.
Thermal decomposition can lead to release of irritating gases and vapors. Keep product and empty container away from heat and sources of ignition.
As in any fire, wear self-contained breathing apparatus pressure-demand, MSHA/NIOSH (approved or equivalent) and full protective gear.
Firefighter Protection
As in any fire, wear self-contained breathing apparatus pressure-demand, MSHA/NIOSH (approved or equivalent) and full protective gear.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Do not let this chemical enter the environment.
Sweep up and shovel into suitable containers for disposal.
Materials: suitable containers
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Wear personal protective equipment/face protection. Ensure adequate ventilation. Avoid contact with skin and eyes. Do not breathe dust. Do not breathe mist/vapors/spray. Do not ingest. If swallowed then seek immediate medical assistance.
Keep in a dry, cool and well-ventilated place. Keep container tightly closed.
Handle in accordance with good industrial hygiene and safety practice. Keep away from food, drink and animal feeding stuffs. Do not eat, drink or smoke when using this product. Remove and wash contaminated clothing and gloves, including the inside, before re-use. Wash hands before breaks and after work.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Ensure adequate ventilation, especially in confined areas. Ensure that eyewash stations and safety showers are close to the workstation location. Wherever possible, engineering control measures such as the isolation or enclosure of the process, the introduction of process or equipment changes to minimise release or contact, and the use of properly designed ventilation systems, should be adopted to control hazardous materials at source
Protective gloves. Glove material: Natural rubber, Nitrile rubber, Neoprene, PVC. Breakthrough time: See manufacturers recommendations. EU standard: EN 374. Glove comments: (minimum requirement). Inspect gloves before use. Please observe the instructions regarding permeability and breakthrough time which are provided by the supplier of the gloves. (Refer to manufacturer/supplier for information) Ensure gloves are suitable for the task: Chemical compatibility, Dexterity, Operational conditions, User susceptibility, e.g. sensitisation effects, also take into consideration the specific local conditions under which the product is used, such as the danger of cuts, abrasion. Remove gloves with care avoiding skin contamination.
Goggles (European standard - EN 166)
When workers are facing concentrations above the exposure limit they must use appropriate certified respirators. To protect the wearer, respiratory protective equipment must be the correct fit and be used and maintained properly. Large scale/emergency use: Use a NIOSH/MSHA or European Standard EN 136 approved respirator if exposure limits are exceeded or if irritation or other symptoms are experienced Recommended Filter type: Particulates filter conforming to EN 143. Small scale/Laboratory use: Use a NIOSH/MSHA or European Standard EN 149:2001 approved respirator if exposure limits are exceeded or if irritation or other symptoms are experienced. Recommended half mask:- Particle filtering: EN149:2001 When RPE is used a face piece Fit Test should be conducted
Wear appropriate protective gloves and clothing to prevent skin exposure
No information available.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under normal conditions.
None known, based on information available
Hazardous Polymerization: No information available. Hazardous Reactions: No information available.
Heat, flames and sparks. Exposure to light. Incompatible products.
Bases. Reducing Agent.
Carbon monoxide (CO). Carbon dioxide (CO₂).
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What other names is Palmitic acid known by?
Palmitic acid is also known as: Hexadecanoic acid
What is the hazard signal word for Palmitic acid?
The signal word is no signal word.
What is the physical form of Palmitic acid?
Palmitic acid is a solid appearing as white . It has no information available odor.
What is Palmitic acid used for?
Laboratory chemicals. Sector of use: SU3 - Industrial uses: Uses of substances as such or in preparations at industrial sites. Product category: PC21 - Laboratory chemicals. Process categories: PROC15 - Use as a laboratory reagent. Environmental release category: ERC6a - Industrial use resulting in manufacture of another substance (use of intermediates)
What is the melting point of Palmitic acid?
The melting point is 59 - 63 °C / 138.2 - 145.4 °F and the boiling point is 351.5 °C / 664.7 °F.