NextSDS Logo
Safety Data Sheet EN

MOTIP LEAK DETECTOR 400 ML

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
MOTIP LEAK DETECTOR 400 ML
Product Code
090406

Regulatory Identifiers

CAS Number
N/A

Identified Uses

SU21 Consumer uses: Private households / general public / consumers, SU22 Professional uses: Public domain (administration, education, entertainment, services, craftsmen)

Uses advised against

No further relevant information available.

Manufacturers & Suppliers

E

European Aerosols B.V.

manufacturer

Wolfraamweg 2, NL-8471 XC Wolvega, The Netherlands

+31 (0)561 694400

Emergency Contacts

Emergency Contact

+31 (0)561-694400

09:00h - 17:00h

NPIS National Poisons Information Centre

+44 0344 892 0111

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

corrosion
Eye Dam. Cat. 1 H318
Aerosol Cat. 3 H229

GHS Pictograms

GHS05 - Corrosive

GHS05

Hazard Statements

H229 Pressurised container: May burst if heated.
H318 Causes serious eye damage.

Precautionary Statements

P101 If medical advice is needed, have product container or label at hand.
P102 Keep out of reach of children.
P210 Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
P251 Do not pierce or burn, even after use.
P260 Do not breathe spray.
P410 + P412 Protect from sunlight. Do not expose to temperatures exceeding 50 °C/122 °F.
P501 Dispose of contents / container in accordance with regional regulations.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Alcohols, C9-C16, ethoxylated EC: 619-252-3 97043-91-9 3 - 5% Yes
nitrogen EC: 231-783-9 7727-37-9 2.5% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Supply fresh air; consult doctor in case of complaints.

Skin contact

Generally the product does not irritate the skin.

Eye contact

Rinse opened eye for several minutes under running water. Then consult a doctor.

Ingestion

Drink plenty of water and provide fresh air. Call for a doctor immediately.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use fire extinguishing methods suitable to surrounding conditions.

Specific hazards

During heating or in case of fire poisonous gases are produced.

Firefighter Protection

Mouth respiratory protective device.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Mount respiratory protective device. Wear protective equipment. Keep unprotected persons away.

Environmental

Do not allow to enter sewers/ surface or ground water.

Cleanup methods

Use neutralising agent.

Materials: neutralising agent

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Ensure good ventilation/exhaustion at the workplace.

Storage

Keep container tightly sealed. Observe official regulations on storing packagings with pressurised containers.

Fire prevention

Do not spray onto a naked flame or any incandescent material.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

No further data; see section 7.

Hands

Protective gloves. Material of gloves: Butyl rubber, BR. The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer. Penetration time of glove material: Butyl rubber gloves with a thickness of 0.4 mm are resistant to: Acetone: 480 min, Butyl acetate: 60 min, Ethyl acetate: 170 min, Xylene: 42 min. Butyl rubber gloves with a thickness of 0.4 mm are solvent resistant for 42-480 minutes. As protective measure, we recommend that users and responsible persons for work safety assume solvent resistance length of 42 minutes. Considering the data in section 3 of this SDS, one can assume longer resistance length in particular cases.

Eyes

Tightly sealed goggles

Respiratory

In case of brief exposure or low pollution use respiratory filter device. In case of intensive or longer exposure use self-contained respiratory protective device. Filter A2/P3

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Solubility In Fat
---
Solidification Point
---
Odor Threshold
Not determined.
Flash Point
>100 °C (>212 °F)
Colour
Clear
Explosive Limits
---
Freezing Point
---
Cloud Point
---
Relative Density
---
Dynamic Viscosity
Not determined.
Boiling Point
100 °C (212 °F)
Vapor Density
---
Solubility
---
Decomposition Temperature
Not determined.
Properties Status
---
State Under Standard Conditions
---
Density
0.1 g/cm³ (0.8 lbs/gal)
Appearance
Clear
Kinematic Viscosity
Not determined.
Relative Evaporation Rate
---
Bulk Density
---
Voc Content
---
Flammability
---
Crystallisation Point
---
Physical State
Aerosol
Melting Point
Undetermined.
Solubility In Water
Not miscible or difficult to mix.
Odor
Mild
Lower Explosive Limit
3.2 Vol %
Softening Point
---
Upper Explosive Limit
53 Vol %
Molecular Weight
---
Partition Coefficient
Not determined.
Evaporation Rate
Not applicable.
Colour Intensity
---
Auto Ignition Temperature
398 °C (748.4 °F)
Form
Aerosol
Physical State Data
aerosol
Metal Corrosion
---
Ph
7.1
Vapor Pressure
8500 hPa (6375.5 mm Hg)
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

No decomposition if used according to specifications.

Reactivity

No further relevant information available.

Hazardous reactions

No dangerous reactions known.

Avoid

No further relevant information available.

Incompatible

No further relevant information available.

Decomposition

No dangerous decomposition products known.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
1950
Shipping Name
AEROSOLS
Transport Class
2.2
ADR

Warning: Gases.

IMDG

Warning: Gases.

IATA

Warning: Gases.

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for MOTIP LEAK DETECTOR 400 ML?

The signal word is danger.

What is the physical form of MOTIP LEAK DETECTOR 400 ML?

MOTIP LEAK DETECTOR 400 ML is a aerosol appearing as clear with clear color. It has mild odor.

What is MOTIP LEAK DETECTOR 400 ML used for?

SU21 Consumer uses: Private households / general public / consumers, SU22 Professional uses: Public domain (administration, education, entertainment, services, craftsmen)

What are the hazard statements for MOTIP LEAK DETECTOR 400 ML?

This substance has 2 hazard statements:

  • H229: Pressurised container: May burst if heated.
  • H318: Causes serious eye damage.

What is the melting point of MOTIP LEAK DETECTOR 400 ML?

The melting point is Undetermined. and the boiling point is 100 °C (212 °F).