Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- MOTIP DE-ICER 400 ML
- Product Code
- 000796
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
SU21 Consumer uses: Private households / general public / consumers, SU22 Professional uses: Public domain (administration, education, entertainment, services, craftsmen), Cleaning agent/ Cleaner
Uses advised against
No further relevant information available.
Manufacturers & Suppliers
European Aerosols B.V.
manufacturer
Wolframweg 2, NL-8471 XC Wolvega, The Netherlands
+31 (0)561 694400
Emergency Contacts
Emergency Contact
+31 (0)561-694400
09:00h - 17:00h
NPIS National Poisons Information Centre
+44 0344 892 0111
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS02
Hazard Statements
Precautionary Statements
Manage your Safety Data Sheets
Organize and access chemical safety data with ease
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
Mixture of substances listed below with nonhazardous additions.
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| ethanol EC: 200-578-6 | 64-17-5 | 25 - 50% | Yes |
| ethanediol EC: 203-473-3 | 107-21-1 | 5 - 10% | Yes |
| propane EC: 200-827-9 | 74-98-6 | 5 - 10% | Yes |
| butane (containing < 0,1 % butadiene (203-450-8)) EC: 203-448-7 | 106-97-8 | 2.5 - 5% | Yes |
| isobutane (containing < 0,1 % butadiene (203-450-8)) EC: 200-857-2 | 75-28-5 | 2.5 - 5% | Yes |
| propan-2-ol EC: 200-661-7 | 67-63-0 | 2.5% | Yes |
| ammonia EC: 215-647-6 | 1336-21-6 | 0.5% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Supply fresh air; consult doctor in case of complaints.
Rinse opened eye for several minutes under running water.
Drink plenty of water and provide fresh air. Call for a doctor immediately.
Immediate Medical Attention
No further relevant information available.
Medical Treatment
No further relevant information available.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use fire extinguishing methods suitable to surrounding conditions.
During heating or in case of fire poisonous gases are produced.
Firefighter Protection
Mouth respiratory protective device.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Mount respiratory protective device. Wear protective equipment. Keep unprotected persons away. Keep away from ignition sources.
Do not allow to enter sewers/ surface or ground water.
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Ensure good ventilation/exhaustion at the workplace.
Keep container tightly sealed. Observe official regulations on storing packagings with pressurised containers.
Do not spray onto a naked flame or any incandescent material. Keep ignition sources away - Do not smoke.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
No further data; see item 7.
Not required.
Not required.
In case of brief exposure or low pollution use respiratory filter device. In case of intensive or longer exposure use self-contained respiratory protective device. Filter A2/P3
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
No decomposition if used according to specifications.
No further relevant information available.
No dangerous reactions known.
No further relevant information available.
No further relevant information available.
No dangerous decomposition products known.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- UN1950
- Packing Group
- not regulated
Warning: Gases.
Warning: Gases.
Warning: Gases.
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for MOTIP DE-ICER 400 ML?
The signal word is danger.
What is the physical form of MOTIP DE-ICER 400 ML?
MOTIP DE-ICER 400 ML is a aerosol with colourless color. It has alcohol-like odor.
What is MOTIP DE-ICER 400 ML used for?
SU21 Consumer uses: Private households / general public / consumers, SU22 Professional uses: Public domain (administration, education, entertainment, services, craftsmen), Cleaning agent/ Cleaner
What are the hazard statements for MOTIP DE-ICER 400 ML?
This substance has 1 hazard statement:
- H222: Extremely flammable aerosol. Pressurised container: May burst if heated.
What is the melting point of MOTIP DE-ICER 400 ML?
The melting point is Undetermined. and the boiling point is Not applicable, as aerosol..