NextSDS Logo
Safety Data Sheet EN

LP120/12

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
LP120/12

Regulatory Identifiers

CAS Number
N/A
UFI Code
00FF-60E1-000D-GAYE

Identified Uses

Release agent

Uses advised against

No further relevant information available.

Manufacturers & Suppliers

R

Riepe GmbH & Co. KG

manufacturer

Theodor Rosenbaum Str. 28-30, 32257 Bünde - Deutschland

+49 (0) 5223 - 687407-0

Emergency Contacts

Poison Control Center, Mainz

00 49 / 61 31 / 19 240

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Mixture of the substances listed below with harmless additions (aqueous solution).

Chemical Name CAS Number Concentration Hazardous
ethanol EC: 200-578-6 64-17-5 2.5 - 10% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Supply fresh air; consult doctor in case of symptoms.

Skin contact

The product is not skin irritating.

Eye contact

Rinse opened eye for 15 minutes under running water.

Ingestion

Rinse out mouth and then drink plenty of water. In case of persistent symptoms consult doctor.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

CO2, extinguishing powder or water jet. Fight larger fires with water jet or alcohol-resistant foam.

Unsuitable media

Water with a full water jet.

Specific hazards

Can be released in case of fire: carbon monoxide (CO), carbon dioxide (CO2)

Instructions

Endangered containers in the surrounding area should be cooled with a water-hose.

Firefighter Protection

Wear self-contained breathing apparatus.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Wear protective equipment and keep unprotected persons away.

Environmental

Prevent material from reaching sewage system, holes and cellars.

Cleanup methods

Absorb with liquid-binding material

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Keep containers tightly sealed.

Storage

Store in cool, dry conditions in well sealed containers.

Fire prevention

Protect against direct sunlight, other sources of heat and ignition.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Hands

Solvent resistant gloves. Material of gloves: Butyl rubber, BR. The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer. Material of gloves is recommended for a short-term single use to protect from splashes. For permanent usage contact manufacturer of gloves.

Eyes

Safety glasses

Respiratory

Not necessary if room is well-ventilated.

Skin/Body

Standard protective clothing. Chemical resistant safety-shoes or boots. If skin contact is possible, wear impenetrable protective clothing against this solvent.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Bulk Density
---
Odor Threshold
Not determined.
Form
Fluid
Auto Ignition Temperature
Not determined.
Density
0.99 g/cm³
State Under Standard Conditions
---
Flash Point
62 °C
Upper Explosive Limit
15 Vol %
Solubility
---
Physical State Data
liquid
Lower Explosive Limit
3.5 Vol %
Decomposition Temperature
Not determined.
Physical State
Fluid
Partition Coefficient
Not determined.
Melting Point
Not determined
Voc Content
---
Solidification Point
---
Kinematic Viscosity
Not determined.
Ph
~9.9
Cloud Point
---
Dynamic Viscosity
Not determined.
Flammability
Not applicable.
Vapor Density
Not determined.
Explosive Limits
---
Solubility In Water
Fully miscible
Freezing Point
Not determined
Properties Status
---
Relative Density
Not determined.
Relative Evaporation Rate
---
Crystallisation Point
---
Vapor Pressure
Not determined.
Molecular Weight
---
Colour Intensity
---
Boiling Point
> 78 °C
Appearance
---
Metal Corrosion
---
Softening Point
---
Odor
Alcohol-like
Colour
Colourless
Evaporation Rate
Not determined.
Solubility In Fat
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

No decomposition if used and stored according to specifications.

Reactivity

No further relevant information available.

Hazardous reactions

No dangerous reactions known

Avoid

No further relevant information available.

Incompatible

strong oxidizing agents

Decomposition

Formation of carbon monoxide and carbon dioxide in case of fire.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for LP120/12?

The signal word is no signal word.

What is the physical form of LP120/12?

LP120/12 is a fluid with colourless color. It has alcohol-like odor.

What is LP120/12 used for?

Release agent

What is the melting point of LP120/12?

The melting point is Not determined and the boiling point is > 78 °C.