NextSDS Logo
Safety Data Sheet EN

Tork Constant Air Freshener Odor Neutralizer

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Tork Constant Air Freshener Odor Neutralizer
Product Code
11436601-00001

Regulatory Identifiers

CAS Number
N/A

Identified Uses

perfumes

Uses advised against

Not applicable

Manufacturers & Suppliers

E

Essity Professional Hygiene NA

manufacturer

P.O. Box 2400, Neenah, United States of America WI 54957-2400

Emergency Contacts

CHEMTREC

1-800-424-9300

24-Hour

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified warning

Hazard Classifications

Flam. Liq. Cat. 4
Skin Sens. Cat. 1

GHS Pictograms

GHS07 - Health hazard

GHS07

Hazard Statements

H227 Combustible liquid.
H317 May cause an allergic skin reaction.

Precautionary Statements

P210 Keep away from heat, sparks, open flame and hot surfaces. No smoking.
P261 Avoid breathing mist or vapors.
P272 Contaminated work clothing must not be allowed out of the workplace.
P280 Wear protective gloves, eye protection and face protection.
P302 + P352 IF ON SKIN: Wash with plenty of soap and water.
P333 + P313 If skin irritation or rash occurs: Get medical attention.
P363 Wash contaminated clothing before reuse.
P403 + P235 Store in a well-ventilated place. Keep cool.
P501 Dispose of contents and container to an approved waste disposal plant.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Dimethyl octadienol 78-70-6 5 - 10% No
3,7-Dimethyl 2,6-octadienal 5392-40-5 0.1 - 1% No
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

If inhaled, remove to fresh air. Get medical attention if symptoms occur.

Skin contact

In case of contact, immediately flush skin with plenty of water. Remove contaminated clothing and shoes. Get medical attention. Wash clothing before reuse. Thoroughly clean shoes before reuse.

Symptoms: May cause an allergic skin reaction.

Eye contact

Flush eyes with water as a precaution. Get medical attention if irritation develops and persists.

Ingestion

If swallowed, DO NOT induce vomiting. Get medical attention if symptoms occur. Rinse mouth thoroughly with water.

Immediate Medical Attention

Get medical attention if symptoms occur.

Medical Treatment

Treat symptomatically and supportively.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Water spray, Alcohol-resistant foam, Carbon dioxide (CO2), Dry chemical

Unsuitable media

High volume water jet

Specific hazards

Do not use a solid water stream as it may scatter and spread fire. Flash back possible over considerable distance. Vapors may form explosive mixtures with air. Exposure to combustion products may be a hazard to health.

Instructions

Use extinguishing measures that are appropriate to local circumstances and the surrounding environment. Use water spray to cool unopened containers. Remove undamaged containers from fire area if it is safe to do so. Evacuate area.

Firefighter Protection

In the event of fire, wear self-contained breathing apparatus. Use personal protective equipment.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Remove all sources of ignition. Use personal protective equipment. Follow safe handling advice (see section 7) and personal protective equipment recommendations (see section 8).

Large spill

For large spills, provide diking or other appropriate containment to keep material from spreading. If diked material can be pumped, store recovered material in appropriate container.

Environmental

Avoid release to the environment. Prevent further leakage or spillage if safe to do so. Prevent spreading over a wide area (e.g., by containment or oil barriers). Retain and dispose of contaminated wash water.

Cleanup methods

Non-sparking tools should be used. Soak up with inert absorbent material. Suppress (knock down) gases/vapors/mists with a water spray jet. Clean up remaining materials from spill with suitable absorbent.

Materials: inert absorbent material

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Do not get on skin or clothing. Avoid breathing mist or vapors. Do not swallow. Avoid contact with eyes. Handle in accordance with good industrial hygiene and safety practice, based on the results of the workplace exposure assessment. Keep container tightly closed. Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking. Take precautionary measures against static discharges. Take care to prevent spills, waste and minimize release to the environment.

Storage

Keep in properly labeled containers. Keep tightly closed. Keep in a cool, well-ventilated place. Store in accordance with the particular national regulations. Keep away from heat and sources of ignition.

Hygiene

Handle in accordance with good industrial hygiene and safety practice

Fire prevention

Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Ensure adequate ventilation, especially in confined areas. Minimize workplace exposure concentrations.

Hands

Material: Chemical-resistant gloves. Break through time: > 10 min. Remarks: Choose gloves to protect hands against chemicals depending on the concentration specific to place of work. For special applications, we recommend clarifying the resistance to chemicals of the aforementioned protective gloves with the glove manufacturer.

Eyes

Wear the following personal protective equipment: Safety glasses

Respiratory

General and local exhaust ventilation is recommended to maintain vapor exposures below recommended limits. Where concentrations are above recommended limits or are unknown, appropriate respiratory protection should be worn. Follow OSHA respirator regulations (29 CFR 1910.134) and use NIOSH/MSHA approved respirators. Protection provided by air purifying respirators against exposure to any hazardous chemical is limited. Use a positive pressure air supplied respirator if there is any potential for uncontrolled release, exposure levels are unknown, or any other circumstance where air purifying respirators may not provide adequate protection.

Skin/Body

Select appropriate protective clothing based on chemical resistance data and an assessment of the local exposure potential. Wear the following personal protective equipment: Skin contact must be avoided by using impervious protective clothing (gloves, aprons, boots, etc).

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
liquid
Colour
red
Colour Intensity
---
Form
---
Odor
fruity
Odor Threshold
No data available
Ph
substance/mixture is non-soluble (in water)
Melting Point
No data available
Boiling Point
No data available
Flash Point
149 °F / 65 °C
Freezing Point
No data available
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
---
Vapor Pressure
0.37 hPa (68 °F / 20 °C)
Vapor Density
---
Relative Density
---
Bulk Density
---
Density
0.9832 g/cm³ (68 °F / 20 °C)
Flammability
Not applicable
Upper Explosive Limit
No data available
Lower Explosive Limit
No data available
Explosive Limits
---
Auto Ignition Temperature
No data available
Decomposition Temperature
No data available
Solubility
---
Partition Coefficient
Not applicable
Solubility In Water
practically insoluble
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
No data available
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under normal conditions.

Reactivity

Not classified as a reactivity hazard.

Hazardous reactions

Combustible liquid. Vapors may form explosive mixture with air. Can react with strong oxidizing agents.

Avoid

Heat, flames and sparks.

Incompatible

Oxidizing agents

Decomposition

No hazardous decomposition products are known.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
NA 1993
Shipping Name
Combustible liquid, n.o.s. (Dimethyl octadienol)
Transport Class
CBL
Packing Group
III
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Tork Constant Air Freshener Odor Neutralizer?

The signal word is warning.

What is the physical form of Tork Constant Air Freshener Odor Neutralizer?

Tork Constant Air Freshener Odor Neutralizer is a liquid appearing as liquid with red color. It has fruity odor.

What is Tork Constant Air Freshener Odor Neutralizer used for?

perfumes

What are the hazard statements for Tork Constant Air Freshener Odor Neutralizer?

This substance has 2 hazard statements:

  • H227: Combustible liquid.
  • H317: May cause an allergic skin reaction.

What is the melting point of Tork Constant Air Freshener Odor Neutralizer?

The melting point is No data available and the boiling point is No data available.