Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Rittal Decklack
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Paint
Uses advised against
No further relevant information available.
Manufacturers & Suppliers
RITTAL GmbH & Co.KG
manufacturer
Auf dem Stützelberg D-35745 Herborn
+49 2772 505 0
Emergency Contacts
Informationszentrale gegen Vergiftungen Bonn
0228/19240
Informationszentrale gegen Vergiftungen Bonn
0228/287-3-3480
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS02
GHS07
GHS08
GHS09
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Hydrocarbons, C9, aromatics EC: 918-668-5 | 64742-95-6 | 25 - 50% | Yes |
| Xylene EC: 215-535-7 | 1330-20-7 | 10 - 20% | Yes |
| Ethylbenzene EC: 202-849-4 | 100-41-4 | 2.5 - 10% | Yes |
| 2-Methoxy-1-methylethyl acetate EC: 203-603-9 | 108-65-6 | 2.5 - 10% | Yes |
| 2-Butoxyethyl acetate EC: 203-933-3 | 112-07-2 | 1 - 2.5% | Yes |
| Reaction mass ofpentamethyl-piperidyl sebacate EC: 915-687-0 | --- | 0.25 - 1% | Yes |
| Toluene EC: 203-625-9 | 108-88-3 | 1% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Supply fresh air and to be sure call for a doctor. In case of unconsciousness place patient stably in side position for transportation.
Immediately rinse with water.
Rinse opened eye for several minutes under running water. If symptoms persist, consult a doctor.
If symptoms persist consult doctor.
Immediate Medical Attention
If symptoms persist, consult a doctor.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
CO2, powder or water spray. Fight larger fires with water spray or alcohol resistant foam.
Water with full jet
During heating or in case of fire poisonous gases are produced.
Firefighter Protection
Mouth respiratory protective device.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Mount respiratory protective device. Wear protective equipment. Keep unprotected persons away.
Do not allow product to reach sewage system or any water course. Do not allow to enter sewers/ surface or ground water.
Absorb with liquid-binding material
Materials: sand, diatomite, acid binders, universal binders, sawdust
Related Products
Similar products with comparable safety profiles
Aerosol NC Decklack uni glanz, schwarz
---
MOTIP Industrial Coatings RAL colors 400ml
---
534/G150 - DECK PAINT (All colours)
---
Aerosol NC Industrielack uni mattiert, diff colors
---
Rösler Alu-Cast RAC-R
---
880/L 24541 herkula ultracoat spezial farblos matt
---
Aerosol NC Industrielack uni glanz, diff colors
---
Aerosol NC Industrielack uni glanz, diff colors
---
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Ensure good ventilation/exhaustion at the workplace. Prevent formation of aerosols.
Keep container tightly sealed.
Keep ignition sources away - Do not smoke. Protect against electrostatic charges. Keep respiratory protective device available.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
No decomposition if used according to specifications.
No further relevant information available.
No dangerous reactions known.
No further relevant information available.
No further relevant information available.
Carbon monoxide
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 1263
- Shipping Name
- PAINT
- Transport Class
- 3
- Packing Group
- III
Warning: Flammable liquids.
Warning: Flammable liquids.
Warning: Flammable liquids.
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Rittal Decklack?
The signal word is warning.
What is the physical form of Rittal Decklack?
Rittal Decklack is a fluid appearing as fluid with according to product specification color. It has characteristic odor.
What is Rittal Decklack used for?
Paint
What are the hazard statements for Rittal Decklack?
This substance has 7 hazard statements:
- H226: Flammable liquid and vapour.
- H315: Causes skin irritation.
- H317: May cause an allergic skin reaction.
- H319: Causes serious eye irritation.
- H335: May cause respiratory irritation. May cause drowsiness or dizziness.
- H373: May cause damage to organs through prolonged or repeated exposure.
- H411: Toxic to aquatic life with long lasting effects.
What is the melting point of Rittal Decklack?