Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Sodium metaperiodate for analysis EMSURE® ACS,Reag. Ph Eur
- Product Code
- 1.06597
Regulatory Identifiers
- CAS Number
- 7790-28-5 Check regulations →
- REACH No.
- A registration number is not available for this substance as the substance or its uses are exempted from registration or the annual tonnage does not require a registration.
Identified Uses
Reagent for analysis
Manufacturers & Suppliers
Sigma-Aldrich Ireland Limited
manufacturer
Vale Road, Arklow, CO WICKLOW, IRELAND
+353 402-20300
Emergency Contacts
CHEMTREC
+(353)-19014670
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS03
GHS05
GHS08
GHS09
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| sodium metaperiodate EC: 232-197-6 | 7790-28-5 | 90 - 100% | No |
First Aid Measures
Emergency procedures for chemical exposure incidents
After inhalation: fresh air. Call in physician.
Take off immediately all contaminated clothing. Rinse skin with water/ shower. Call a physician immediately.
After eye contact: rinse out with plenty of water. Immediately call in ophthalmologist. Remove contact lenses.
After swallowing: make victim drink water (two glasses at most), avoid vomiting (risk of perforation). Call a physician immediately. Do not attempt to neutralise.
Immediate Medical Attention
Call a physician immediately.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use extinguishing measures that are appropriate to local circumstances and the surrounding environment.
For this substance/mixture no limitations of extinguishing agents are given.
Not combustible. Fire may cause evolution of: hydrogen iodide. Has a fire-promoting effect due to release of oxygen. Ambient fire may liberate hazardous vapours.
Firefighter Protection
Stay in danger area only with self-contained breathing apparatus. Prevent skin contact by keeping a safe distance or by wearing suitable protective clothing.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
observe emergency procedures, consult an expert
Do not let product enter drains.
Take up dry. Dispose of properly. Clean up affected area.
Related Products
Similar products with comparable safety profiles
Sodium acetate trihydrate for analysis EMSURE® ACS,ISO,Reag. Ph Eur
CAS: 6131-90-4
Sodium perchlorate monohydrate for analysis EMSURE®
CAS: 7791-07-3
Sodium perchlorate monohydrate for analysis EMSURE®
CAS: 7791-07-3
Ethyl acetate for analysis EMSURE® ACS,ISO,Reag. Ph Eur
CAS: 141-78-6
di-Ammonium hydrogen citrate for analysis EMSURE® ACS,Reag. Ph Eur
---
Ammonium nitrate for analysis EMSURE® ACS
CAS: 6484-52-2
Chloroform for analysis EMSURE® ACS,ISO,Reag. Ph Eur
CAS: 67-66-3
Potassium dichromate for analysis EMSURE® ACS,ISO,Reag. Ph Eur
CAS: 7778-50-9
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
For precautions see section 2.2.
Tightly closed. Keep locked up or in an area accessible only to qualified or authorised persons. Separately or together with other oxidising substances only and away from sources of ignition and heat.
Immediately change contaminated clothing. Apply preventive skin protection. Wash hands and face after working with substance.
Keep away from open flames, hot surfaces and sources of ignition.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Material: Nitrile rubber; Break through time: 480 min; Glove thickness: 0.11 mm; Protective index: Full contact / Splash contact; Manufacturer: KCL 741 Dermatril® L. Remarks: This recommendation applies only to the product stated in the safety data sheet, supplied by us and for the designated use. When dissolving in or mixing with other substances and under conditions deviating from those stated in EN 16523-1 please contact the supplier of CE-approved gloves (e.g. KCL GmbH, D-36124 Eichenzell, Internet: www.kcl.de).
Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU). Tightly fitting safety goggles
required when dusts are generated. Our recommendations on filtering respiratory protection are based on the following standards: DIN EN 143, DIN 14387 and other accompanying standards relating to the used respiratory protection system. Recommended Filter type: Filter type P2. The entrepeneur has to ensure that maintenance, cleaning and testing of respiratory protective devices are carried out according to the instructions of the producer. These measures have to be properly documented.
protective clothing
Do not let product enter drains.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
The product is chemically stable under standard ambient conditions (room temperature) .
No data available
Violent reactions possible with: combustible substances, ammonium compounds, perchlorates, Powdered metals, Reducing agents, acids, magnesium
no information available
No data available
In the event of fire: see section 5
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 3085
- Shipping Name
- OXIDIZING SOLID, CORROSIVE, N.O.S. (sodium metaperiodate)
- Transport Class
- 5.1 (8)
- Packing Group
- I
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Sodium metaperiodate for analysis EMSURE® ACS,Reag. Ph Eur?
The signal word is danger.
What is the physical form of Sodium metaperiodate for analysis EMSURE® ACS,Reag. Ph Eur?
Sodium metaperiodate for analysis EMSURE® ACS,Reag. Ph Eur is a solid (20 °c, 1,013 hpa) with white color. It has odourless odor.
What is Sodium metaperiodate for analysis EMSURE® ACS,Reag. Ph Eur used for?
Reagent for analysis
What are the hazard statements for Sodium metaperiodate for analysis EMSURE® ACS,Reag. Ph Eur?
This substance has 4 hazard statements:
- H271: May cause fire or explosion; strong oxidizer.
- H314: Causes severe skin burns and eye damage.
- H372: Causes damage to organs (Thyroid) through prolonged or repeated exposure.
- H410: Very toxic to aquatic life with long lasting effects.
What is the melting point of Sodium metaperiodate for analysis EMSURE® ACS,Reag. Ph Eur?
The melting point is 270 °C (1,013 hPa) Decomposition: yes Method: OECD Test Guideline 102 GLP: yes Decomposes before melting. and the boiling point is No data available.