Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Gadolinium(III) chloride hexahydrate, REacton®
- Product Code
- 11286
- Chemical Name
- Gadolinium(III) chloride hexahydrate
Regulatory Identifiers
- CAS Number
- 13450-84-5 Check regulations →
Identified Uses
Laboratory chemicals.
Uses advised against
No Information available
Manufacturers & Suppliers
Thermo Fisher (Kandel) GmbH
manufacturer
Zeppelinstr. 7b 76185 Karlsruhe / Germany
+49 (0) 721 84007 280
http://www.alfa.com
Emergency Contacts
Carechem 24
+44 (0) 1235 239 670
Poison Information Center Mainz
+49(0)6131/19240
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS07
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Gadolinium chloride (GdCI3), hexahydrate | 13450-84-5 | 100% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Move to fresh air. If not breathing, give artificial respiration. Get medical attention if symptoms occur.
Wash off immediately with plenty of water for at least 15 minutes. If skin irritation persists, call a physician.
Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. Get medical attention.
Clean mouth with water and drink afterwards plenty of water. Get medical attention if symptoms occur.
Medical Treatment
Treat symptomatically.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Not combustible.
No information available.
Thermal decomposition can lead to release of irritating gases and vapors.
Firefighter Protection
As in any fire, wear self-contained breathing apparatus pressure-demand, MSHA/NIOSH (approved or equivalent) and full protective gear.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Ensure adequate ventilation. Use personal protective equipment. Avoid dust formation.
Should not be released into the environment. See Section 12 for additional ecological information.
Sweep up or vacuum up spillage and collect in suitable container for disposal.
Materials: suitable container
Related Products
Similar products with comparable safety profiles
HEXAMETHYLENETETRAMINE, REAGENT, ACS
---
Fast red TR hemi(zinc chloride) salt
CAS: 89453-69-0
Strontium chloride hexahydrate for analysis EMSURE® ACS
CAS: 10025-70-4
Iron(III) chloride hexahydrate for analysis EMSURE® ACS, Reag. Ph Eur
CAS: 10025-77-1
Iron(III) chloride hexahydrate for analysis EMSURE® ACS, Reag. Ph Eur
CAS: 10025-77-1
Chromium(III) chloride hexahydrate
CAS: 10060-12-5
Magnesium chloride hexahydrate for analysis EMSURE® ACS, ISO, Reag. Ph Eur
CAS: 7791-18-6
Rhodium(III)chloride trihydrate
CAS: 13569-65-8
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Wear personal protective equipment. Ensure adequate ventilation. Avoid ingestion and inhalation. Avoid dust formation. Do not get in eyes, on skin, or on clothing.
Store under an inert atmosphere. Keep container tightly closed in a dry and well-ventilated place. Protect from moisture.
Handle in accordance with good industrial hygiene and safety practice. Keep away from food, drink and animal feeding stuffs. Do not eat, drink or smoke when using this product. Remove and wash contaminated clothing before re-use. Wash hands before breaks and at the end of workday.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
None under normal use conditions. Ensure that eyewash stations and safety showers are close to the workstation location.
Protective gloves. Glove material: Natural rubber, Nitrile rubber, Neoprene, PVC. Breakthrough time: See manufacturers recommendations. Glove thickness: -. EU standard: EN 374. Glove comments: (minimum requirement). Inspect gloves before use. observe the instructions regarding permeability and breakthrough time which are provided by the supplier of the gloves. (Refer to manufacturer/supplier for information) gloves are suitable for the task: Chemical compatability, Dexterity, Operational conditions, User susceptibility, e.g. sensitisation effects, also take into consideration the specific local conditions under which the product is used, such as the danger of cuts, abrasion. gloves with care avoiding skin contamination.
Goggles (European standard - EN 166)
No protective equipment is needed under normal use conditions. Large scale/emergency use: Use a NIOSH/MSHA or European Standard EN 136 approved respirator if exposure limits are exceeded or if irritation or other symptoms are experienced. Recommended Filter type: Particle filter. Small scale/Laboratory use: Maintain adequate ventilation
Long sleeved clothing
No information available.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Hygroscopic.
None known, based on information available
Hazardous Polymerization: No information available. Hazardous Reactions: None under normal processing.
Exposure to moist air or water.
Acids. Strong bases. Oxidizing agents.
Hydrogen chloride. Gadolinium oxide.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Gadolinium(III) chloride hexahydrate, REacton®?
The signal word is warning.
What is the physical form of Gadolinium(III) chloride hexahydrate, REacton®?
Gadolinium(III) chloride hexahydrate, REacton® is a solid crystalline appearing as solid crystalline . It has no information available odor.
What is Gadolinium(III) chloride hexahydrate, REacton® used for?
Laboratory chemicals.
What are the hazard statements for Gadolinium(III) chloride hexahydrate, REacton®?
This substance has 2 hazard statements:
- H315: Causes skin irritation
- H319: Causes serious eye irritation
What is the melting point of Gadolinium(III) chloride hexahydrate, REacton®?
The melting point is No data available and the boiling point is No information available.