Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Strontium chloride hexahydrate for analysis EMSURE® ACS
- Product Code
- 107865
- Chemical Name
- Strontium chloride hexahydrate
Regulatory Identifiers
- CAS Number
- 10025-70-4 Check regulations →
- REACH No.
- A registration number is not available for this substance as the substance or its use are exempted from registration according to Article 2 REACH Regulation (EC) No 1907/2006, the annual tonnage does not require a registration or the registration is envisaged for a later registration deadline.
Identified Uses
Reagent for analysis
Manufacturers & Suppliers
Merck KGaA
manufacturer
64271 Darmstadt, Germany
+49 6151 72-0
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS07
Hazard Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| strontium chloride hexahydrate EC: 233-971-6 | 10025-70-4 | 100% | Yes |
For the full text of the H-Statements mentioned in this Section, see Section 16. For the full text of the R-phrases mentioned in this Section, see Section 16.
First Aid Measures
Emergency procedures for chemical exposure incidents
After inhalation: fresh air.
After skin contact: wash off with plenty of water. Remove contaminated clothing.
After eye contact: rinse out with plenty of water.
After swallowing: immediately make victim drink water (two glasses at most). Consult a physician.
Symptoms: Drowsiness, Diarrhoea
Immediate Medical Attention
Consult a physician.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use extinguishing measures that are appropriate to local circumstances and the surrounding environment.
For this substance/mixture no limitations of extinguishing agents are given.
Not combustible. Ambient fire may liberate hazardous vapours.
Suppress (knock down) gases/vapours/mists with a water spray jet.
Firefighter Protection
Stay in danger area only with self-contained breathing apparatus. Prevent skin contact by keeping a safe distance or by wearing suitable protective clothing.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Avoid substance contact. Avoid inhalation of dusts. Ensure adequate ventilation. Evacuate the danger area, observe emergency procedures, consult an expert.
Do not empty into drains.
Take up dry. Clean up affected area.
Related Products
Similar products with comparable safety profiles
Iron(III) chloride hexahydrate for analysis EMSURE® ACS, Reag. Ph Eur
CAS: 10025-77-1
Iron(III) chloride hexahydrate for analysis EMSURE® ACS, Reag. Ph Eur
CAS: 10025-77-1
Sodium perchlorate monohydrate for analysis EMSURE®
CAS: 7791-07-3
Sodium perchlorate monohydrate for analysis EMSURE®
CAS: 7791-07-3
Potassium dichromate for analysis EMSURE® ACS,ISO,Reag. Ph Eur
CAS: 7778-50-9
Tungstophosphoric acid hydrate for analysis EMSURE®
CAS: 12501-23-4
Ammonium nitrate for analysis EMSURE® ACS
CAS: 6484-52-2
Sodium acetate trihydrate for analysis EMSURE® ACS,ISO,Reag. Ph Eur
CAS: 6131-90-4
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Observe label precautions.
Tightly closed. Dry. Recommended storage temperature see product label.
Change contaminated clothing. Preventive skin protection recommended. Wash hands after working with substance.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Technical measures and appropriate working operations should be given priority over the use of personal protective equipment. See section 7.1.
full contact: Glove material: Nitrile rubber, Glove thickness: 0,11 mm, Break through time: > 480 min; splash contact: Glove material: Nitrile rubber, Glove thickness: 0,11 mm, Break through time: > 480 min. The protective gloves to be used must comply with the specifications of EC Directive 89/686/EEC and the related standard EN374, for example KCL 741 Dermatril® L (full contact), KCL 741 Dermatril® L (splash contact).
Safety glasses
required when dusts are generated. Recommended Filter type: Filter P 2 (acc. to DIN 3181) for solid and liquid particles of harmful substances. The entrepreneur has to ensure that maintenance, cleaning and testing of respiratory protective devices are carried out according to the instructions of the producer. These measures have to be properly documented.
protective clothing
Do not empty into drains.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
The product is chemically stable under standard ambient conditions (room temperature).
See section 10.3
Dangerous reactions are not expected handling the product according to its intended use.
no data available
no information available
in the event of fire: See section 5.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
See www.retrologistik.com for processes regarding the return of chemicals and containers, or contact us there if you have further questions.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The Safety Data Sheets for catalogue items are available at www.merck-chemicals.com
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Strontium chloride hexahydrate for analysis EMSURE® ACS?
The signal word is warning.
What is the physical form of Strontium chloride hexahydrate for analysis EMSURE® ACS?
Strontium chloride hexahydrate for analysis EMSURE® ACS is a solid with white color. It has odourless odor.
What is Strontium chloride hexahydrate for analysis EMSURE® ACS used for?
Reagent for analysis
What are the hazard statements for Strontium chloride hexahydrate for analysis EMSURE® ACS?
This substance has 1 hazard statement:
- H302: Harmful if swallowed.
What is the melting point of Strontium chloride hexahydrate for analysis EMSURE® ACS?
The melting point is ca. 61 °C and the boiling point is No information available..