NextSDS Logo
Safety Data Sheet EN

TruLab L

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
TruLab L
Product Code
5 9020 XX XX XXX (Level 1), 5 9030 XX XX XXX (Level 2)

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Reagent for in-vitro diagnostics in human samples. For professional use only.

Manufacturers & Suppliers

DiaSys Diagnostic Systems GmbH logo

DiaSys Diagnostic Systems GmbH

manufacturer

Alte Strasse 9, DE-65558 Holzheim

+49 (0) 6432-9146-0

http://www.diasys.de

Emergency Contacts

Infraserv

+49 (0) 69-305-6418

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Lyophilisate

The product does not contain dangerous substances above limits that need to be mentioned in this section according to applicable EU-legislation.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Move victim to fresh air. Seek medical treatment in case of troubles.

Skin contact

After contact with skin, wash immediately with soap and plenty of water. In case of skin reactions, consult a physician.

Eye contact

Immediately flush eyes with plenty of flowing water for 10 to 15 minutes holding eyelids apart. Remove contact lenses, if present and easy to do. Continue rinsing. In case of troubles or persistent symptoms, consult an ophthalmologist.

Ingestion

Rinse mouth immediately and drink plenty of water. Never give anything by mouth to an unconscious person. Induce vomiting. Seek medical attention.

Medical Treatment

Treat symptomatically.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Product is non-combustible. Extinguishing materials should therefore be selected according to surroundings.

Specific hazards

Fires in the immediate vicinity may cause the development of dangerous vapours.

Firefighter Protection

Wear self-contained breathing apparatus.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Wear appropriate protective equipment. Avoid contact with the substance. Do not inhale substance.

Environmental

Do not allow to penetrate into soil, waterbodies or drains.

Cleanup methods

Take up mechanically, placing in appropriate containers for disposal.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Provide adequate ventilation, and local exhaust as needed. Avoid contact with skin, eyes, and clothing. Do not inhale substance. After worktime and during work intervals the affected skin areas must be thoroughly cleaned. Wear appropriate protective equipment. Take off contaminated clothing and wash it before reuse. Safety shower and eye wash station should be easily accessible to the work area.

Storage

Keep container in a well-ventilated place. Keep containers tightly closed and at a temperature between 2 °C and 8 °C. Do not freeze. Protect from light. Keep sterile.

Hygiene

After worktime and during work intervals the affected skin areas must be thoroughly cleaned. Take off contaminated clothing and wash it before reuse.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Provide good ventilation and/or an exhaust system in the work area.

Hands

Protective gloves according to EN 374. Glove material: Nitrile rubber - Breakthrough time: >480 min. Observe glove manufacturer's instructions concerning penetrability and breakthrough time.

Eyes

Tightly sealed goggles according to EN 166.

Respiratory

Provide adequate ventilation.

Skin/Body

Wear suitable protective clothing.

Environmental

Refer to "6.2 Environmental precautions".

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Odor Threshold
No data available
Vapor Pressure
No data available
Form
lyophilisate
Density
No data available
Vapor Density
No data available
Solubility
---
Lower Explosive Limit
No data available
Colour
white
Melting Point
No data available
Explosive Limits
---
Crystallisation Point
---
Relative Evaporation Rate
---
Cloud Point
---
Solubility In Fat
---
Kinematic Viscosity
No data available
Flash Point
not combustible
Solubility In Water
complete soluble
Physical State
solid
Evaporation Rate
No data available
Colour Intensity
---
Solidification Point
---
Odor
no characteristic odour
Properties Status
---
Flammability
No data available
State Under Standard Conditions
---
Partition Coefficient
No data available
Bulk Density
---
Molecular Weight
---
Softening Point
---
Appearance
---
Ph
Not applicable
Metal Corrosion
---
Relative Density
---
Decomposition Temperature
---
Upper Explosive Limit
No data available
Freezing Point
---
Physical State Data
solid
Boiling Point
No data available
Voc Content
---
Auto Ignition Temperature
No data available
Dynamic Viscosity
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under recommended storage conditions.

Reactivity

Refer to subsection "Possibility of hazardous reactions".

Hazardous reactions

No hazardous reactions known.

Avoid

Protect against heat /sun rays.

Incompatible

Strong acids and alkalis

Decomposition

No decomposition when used properly. Thermal decomposition: No data available

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for TruLab L?

The signal word is no signal word.

What is the physical form of TruLab L?

TruLab L is a solid with white color. It has no characteristic odour odor.

What is TruLab L used for?

Reagent for in-vitro diagnostics in human samples. For professional use only.

What is the melting point of TruLab L?

The melting point is No data available and the boiling point is No data available.