Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- TruCal Lipid
- Product Code
- 1 3570 XX XX XXX
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Reagent for in-vitro diagnostics in human samples. For professional use only.
Manufacturers & Suppliers
DiaSys Diagnostic Systems GmbH
manufacturer
Alte Strasse 9, DE-65558 Holzheim
+49 (0) 6432-9146-0
http://www.diasys.de
Emergency Contacts
Infraserv
+49 (0) 69-305-6418
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
Lyophilisate
The product does not contain dangerous substances above limits that need to be mentioned in this section according to applicable EU-legislation.
First Aid Measures
Emergency procedures for chemical exposure incidents
Move victim to fresh air.
After contact with skin, wash immediately with soap and plenty of water.
Immediately flush eyes with plenty of flowing water for 10 to 15 minutes holding eyelids apart. Remove contact lenses, if present and easy to do. Continue rinsing.
Rinse mouth immediately and drink plenty of water. Never give anything by mouth to an unconscious person. Induce vomiting.
Immediate Medical Attention
Seek medical treatment in case of troubles (inhalation). In case of skin reactions, consult a physician. In case of troubles or persistent symptoms, consult an ophthalmologist. Seek medical attention (swallowing).
Medical Treatment
Treat symptomatically.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Product is non-combustible. Extinguishing materials should therefore be selected according to surroundings.
Fires in the immediate vicinity may cause the development of dangerous vapours.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Wear appropriate protective equipment. Avoid contact with the substance. Do not inhale substance. Provide adequate ventilation.
Do not allow to penetrate into soil, waterbodies or drains.
Take up mechanically, placing in appropriate containers for disposal.
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Provide adequate ventilation, and local exhaust as needed. Avoid contact with skin, eyes, and clothing. Do not inhale substance. After worktime and during work intervals the affected skin areas must be thoroughly cleaned. Wear appropriate protective equipment. Take off contaminated clothing and wash it before reuse. Safety shower and eye wash station should be easily accessible to the work area.
Keep container in a well-ventilated place. Keep containers tightly closed and at a temperature between 2 °C and 8 °C. Do not freeze. Protect from light. Keep sterile.
After worktime and during work intervals the affected skin areas must be thoroughly cleaned. Take off contaminated clothing and wash it before reuse.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Provide good ventilation and/or an exhaust system in the work area.
Protective gloves according to EN 374. Glove material: Nitrile rubber - Breakthrough time: >480 min. Observe glove manufacturer's instructions concerning penetrability and breakthrough time.
Tightly sealed goggles according to EN 166.
Provide adequate ventilation.
Wear suitable protective clothing.
Refer to "6.2 Environmental precautions".
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under recommended storage conditions.
Refer to subsection 'Possibility of hazardous reactions'.
No hazardous reactions known.
Protect against heat /sun rays.
Strong acids and alkalis
No decomposition when used properly. Thermal decomposition: No data available
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for TruCal Lipid?
The signal word is no signal word.
What is the physical form of TruCal Lipid?
TruCal Lipid is a solid with white color. It has no characteristic odour odor.
What is TruCal Lipid used for?
Reagent for in-vitro diagnostics in human samples. For professional use only.
What is the melting point of TruCal Lipid?
The melting point is No data available and the boiling point is No data available.