NextSDS Logo
Safety Data Sheet EN

OSMO STANDARD SOLUTION

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
OSMO STANDARD SOLUTION

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Use exclusive reagents for Automatic Osmotic Pressure Measurements (OM-6050, OM-6060).

Manufacturers & Suppliers

A

ARKRAY FACTORY, Inc.

manufacturer

1480 Koji, Konan-cho, Koka-shi, Shiga 520-3306, JAPAN

+81-748-86-6901

A

ARKRAY Europe, B. V.

Prof. J. H. Bavincklaan 2, 1183 AT Amstelveen, THE NETHERLANDS

+31-20-545-2450

Emergency Contacts

Emergency Contact

+31-20-545-2450

9:00~17:00

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Sodium chloride EC: 231-598-3 7647-14-5 3% Yes
Sodium azide EC: 247-852-1 26628-22-8 0.1% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove casualty to fresh air and keep at rest. If trouble breathing, get medical attention.

Skin contact

Immediately wash thoroughly with water and soap. Immediately get medical attention if itchiness and inflammation occurs.

Symptoms: itchiness and inflammation

Eye contact

Immediately wash eyes with plenty of clean water for at least 15 minutes and get medical attention.

Ingestion

Rinse mouth. Give one or two glasses of water to drink. Never give anything by mouth if unconscious. Immediately get medical attention.

Immediate Medical Attention

Consult a physician. Immediately get medical attention if trouble breathing, if itchiness and inflammation occurs, or after ingestion.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Water

Unsuitable media

Not specified

Firefighter Protection

Fire-fighters should wear proper protective equipment.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Stay away from the contaminated area. For emergency responder: Wear protective equipment. See Section 8.

Environmental

Flush with plenty of water or wipe off with absorbent such as damp cloth before it dries. Rinse used cloth sufficiently.

Cleanup methods

Rinse with plenty of water.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Wear suitable protective equipment. For personal protection see Section 8.

Storage

Store at temperature of 1 - 30 °C.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Handle in a well-ventilated area.

Hands

Use rubber gloves, if necessary.

Eyes

Use safety glasses, if necessary.

Respiratory

Not necessary

Skin/Body

Not necessary

Environmental

For environmental exposure controls, see Section 6.2.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
---
Colour
Coluorless
Colour Intensity
---
Form
---
Odor
No data available
Odor Threshold
No data available
Ph
5 – 8 (at 25 °C)
Melting Point
No data available
Boiling Point
No data available
Flash Point
No data available
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
---
Vapor Pressure
---
Vapor Density
---
Relative Density
---
Bulk Density
---
Density
---
Flammability
---
Upper Explosive Limit
---
Lower Explosive Limit
---
Explosive Limits
---
Auto Ignition Temperature
---
Decomposition Temperature
---
Solubility
Water
Partition Coefficient
---
Solubility In Water
---
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
---
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under normal conditions.

Reactivity

Stable under normal conditions.

Hazardous reactions

Stable under recommended storage conditions.

Avoid

Sunlight

Incompatible

Store at a distance from incompatible materials.

Decomposition

Does not decompose when used for intended uses.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

ADR

When transporting, make sure that there are no leaks in the container, load it so that it does not fall over, fall, or be damaged, and make sure to prevent it from collapsing.

IMDG

When transporting, make sure that there are no leaks in the container, load it so that it does not fall over, fall, or be damaged, and make sure to prevent it from collapsing.

IATA

When transporting, make sure that there are no leaks in the container, load it so that it does not fall over, fall, or be damaged, and make sure to prevent it from collapsing.

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for OSMO STANDARD SOLUTION?

The signal word is no signal word.

What is the physical form of OSMO STANDARD SOLUTION?

OSMO STANDARD SOLUTION is a liquid with coluorless color. It has no data available odor.

What is the solubility of OSMO STANDARD SOLUTION?

Water

What is OSMO STANDARD SOLUTION used for?

Use exclusive reagents for Automatic Osmotic Pressure Measurements (OM-6050, OM-6060).

What is the melting point of OSMO STANDARD SOLUTION?

The melting point is No data available and the boiling point is No data available.