NextSDS Logo
Safety Data Sheet EN

OC-SENSOR DIANA Latex Reagent

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
OC-SENSOR DIANA Latex Reagent
Product Code
V-PZ01

Regulatory Identifiers

CAS Number
N/A

Manufacturers & Suppliers

E

Eiken Chemical Co., Ltd.

manufacturer

4-19-9, Taito, Taito-ku, Tokyo 110-8408, JAPAN

+81-3-5846-3479

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

N-2-Hydroxyethylpiperazine-N'-2-ethanesulfonic acid 100mM; Polystyrene Latex 0.1%; Contributing to the hazard: Sodium Azide < 0.1% CAS No.: 26628-22-8

Chemical Name CAS Number Concentration Hazardous
N-2-Hydroxyethylpiperazine-N'-2-ethanesulfonic acid --- 100% No
Polystyrene Latex --- 0.1% No
Sodium Azide 26628-22-8 0.1% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Skin contact

Wash with plenty of water.

Eye contact

Rinse cautiously with water for 15 minutes or longer.

Ingestion

Fully rinse mouth out with water.

Immediate Medical Attention

If skin irritation occurs, seek medical advice/attention. If eye irritation persists, get medical advice/attention. If you feel unwell, seek medical advice/treatment.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Water, powder, CO₂, foam

Instructions

Shut off the source of the fire. Use water, powder, CO₂ or other extinguishing media as appropriate for the nature of the blaze. Extinguish the fire from an upwind position.

Firefighter Protection

Wear breathing protection equipment.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Use caution, as the area where the solution was spilled will be slippery.

Environmental

Do not dispose of the spilled or leaked solution directly into a river or sewer. Pour out the solution together with a large volume of water.

Cleanup methods

Wipe up the solution with a waste or disposable cloth. Then wash it away with a large volume of water.

Materials: waste or disposable cloth

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Avoid contact with skin, mucous membranes, or clothes. Avoid getting into eyes. Wash hands thoroughly after handling.

Storage

Store this product in a cool, dark location at 2 – 10°C, and avoid freezing.

Hygiene

Wash hands thoroughly after handling.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Colour
Milky white
Upper Explosive Limit
---
Evaporation Rate
---
Solubility In Water
---
Cloud Point
---
Softening Point
---
Lower Explosive Limit
---
Physical State
Liquid
Bulk Density
---
Vapor Pressure
---
Flash Point
Not applicable
Molecular Weight
---
Solubility
Polystyrene Latex in the solution is insoluble in water. The other components are highly soluble in water.
Properties Status
---
Odor Threshold
---
Ph
7.2 – 7.6
Solidification Point
---
Relative Evaporation Rate
---
Flammability
---
Vapor Density
---
Colour Intensity
---
Dynamic Viscosity
---
Explosive Limits
---
Odor
Odorless
Partition Coefficient
---
Decomposition Temperature
---
Voc Content
---
Crystallisation Point
---
State Under Standard Conditions
---
Kinematic Viscosity
---
Metal Corrosion
---
Melting Point
---
Auto Ignition Temperature
Not applicable
Form
---
Appearance
---
Relative Density
---
Physical State Data
liquid
Freezing Point
---
Solubility In Fat
---
Density
---
Boiling Point
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

This product is stable with regard to heat, light, and physical impact.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for OC-SENSOR DIANA Latex Reagent?

The signal word is no signal word.

What is the physical form of OC-SENSOR DIANA Latex Reagent?

OC-SENSOR DIANA Latex Reagent is a liquid with milky white color. It has odorless odor.

What is the solubility of OC-SENSOR DIANA Latex Reagent?

Polystyrene Latex in the solution is insoluble in water. The other components are highly soluble in water.