Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- LCK 310 Chlor/Ozon/Chlordioxid-Chlorine/Ozone/Chlorine dioxide, Sample cuvette; 1/3
- Product Form
- cuvette
Regulatory Identifiers
- CAS Number
- N/A
- UFI Code
- F4E6-2FK3-S80K-PJ3V
Identified Uses
Water analysis
Manufacturers & Suppliers
HACH LANGE GmbH
manufacturer
Willstätterstr. 11, D-40549 Düsseldorf
+49 (0)211 5288-383
http://www.de.hach.com
HACH LANGE Ltd.
distributor
5, Pacific Way, Salford Manchester M50 1DL - United Kingdom
+44 (0) 161 872 1487
HACH LANGE Ltd.
distributor
Unit 1, Chestnut Road Western Industrial Estate, IRL-Dublin 12
+353 (0)1 4602522
Emergency Contacts
Poison Control Center Mainz
+49 (0) 6131 19240
24 hour emergency service
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS07
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Potassium dihydrogen phosphate EC: 231-913-4 | 7778-77-0 | 50% | Yes |
| di-Sodium hydrogen phosphate EC: 231-448-7 | 7558-79-4 | 27% | Yes |
| N,N-Diethyl-1,4-phenylenediammonium sulfate EC: 228-500-6 | 6283-63-2 | 25% | Yes |
| Ethylenedinitrilotetraacetic acid disodium salt dihydrate EC: 205-358-3 | 6381-92-6 | 0.5% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Move to fresh air.
Wash off immediately with plenty of water. In the case of skin irritation or allergic reactions see a physician.
Rinse thoroughly with plenty of water for at least 15 minutes and consult a physician.
Clean mouth with water and drink afterwards plenty of water. Consult a physician if necessary.
Medical Treatment
Treat symptomatically.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use extinguishing measures that are appropriate to local circumstances and the surrounding environment. The product itself does not burn.
None known.
Fire may liberate hazardous vapours.
Firefighter Protection
In the event of fire, wear self-contained breathing apparatus. Use personal protective equipment.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Use personal protective equipment. For personal protection see section 8.
Do not flush into surface water or sanitary sewer system.
Soak up with inert absorbent material
Materials: sand, silica gel, acid binder, universal binder, sawdust
Related Products
Similar products with comparable safety profiles
LCK 311 Chlorid/Chloride/Chlorure, Sample cuvette, 1/2
UFI: FC05-XFJN-K806-9EWY
LCK 341 Nitrit/Nitrite, Sample cuvette; 1/2
---
LCK 339 Nitrat/Nitrate, Sample cuvette, 1/2
---
LCK 304 Ammonium, Sample cuvette
---
1,4-Dioxane for liquid chromatography LiChrosolv®
CAS: 123-91-1
Chlorate standard solution 1000 µg/mL for IC (Ion HIQU)
CAS: 3811-04-9
Electrolyte KCl – 3 mol/L, 250 mL
---
Electrolyte KCl – 3 mol/L, 250 mL
---
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Use only in well-ventilated areas. Avoid contact with skin, eyes and clothing.
Keep in a dry, cool place.
See also section 5
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Technical measures and appropriate working operations should be given priority over the use of personal protective equipment.
Use barrier skin cream. Chemical resistant gloves made of butyl rubber or nitrile rubber category III according to EN 374. In full contact: Gloves material: Viton, Layer thickness: 0.70 mm, Breakthrough time: >480 min. In splash contact: Glove material: nitrile rubber, Layer thickness 0,20 mm, Breakthrough time: > 30 min
Safety glasses with side-shields
Breathing apparatus only if aerosol or dust is formed. Recommended Filter type: ABEK-filter
Remove and wash contaminated clothing before re-use.
Should not be released into the environment.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under recommended storage conditions.
No dangerous reaction known under conditions of normal use.
Acids, Bases
Extremes of temperature and direct sunlight.
None known.
No decomposition if stored and applied as directed.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for LCK 310 Chlor/Ozon/Chlordioxid-Chlorine/Ozone/Chlorine dioxide, Sample cuvette; 1/3?
The signal word is warning.
What is the physical form of LCK 310 Chlor/Ozon/Chlordioxid-Chlorine/Ozone/Chlorine dioxide, Sample cuvette; 1/3?
LCK 310 Chlor/Ozon/Chlordioxid-Chlorine/Ozone/Chlorine dioxide, Sample cuvette; 1/3 is a solid (lyophilised) with white color. It has odourless odor.
What is LCK 310 Chlor/Ozon/Chlordioxid-Chlorine/Ozone/Chlorine dioxide, Sample cuvette; 1/3 used for?
Water analysis
What are the hazard statements for LCK 310 Chlor/Ozon/Chlordioxid-Chlorine/Ozone/Chlorine dioxide, Sample cuvette; 1/3?
This substance has 3 hazard statements:
- H302: Harmful if swallowed.
- H315: Causes skin irritation.
- H319: Causes serious eye irritation.
What is the melting point of LCK 310 Chlor/Ozon/Chlordioxid-Chlorine/Ozone/Chlorine dioxide, Sample cuvette; 1/3?
The melting point is no data available and the boiling point is not applicable.