Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- LeucoScreen Plus Reagent 1
- Product Form
- Mixture
- Product Code
- LEUCOP1
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
For professional use only. LeucoScreen Plus is a histochemical kit for the determination of peroxidase-positive white blood cells in human semen.
Uses advised against
No additional information available
Manufacturers & Suppliers
FertiPro NV
manufacturer
Industriepark Noord 32, 8730 Beernem, Belgium
Emergency Contacts
Emergency Contact
+3250791805
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS02
GHS06
GHS08
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove victim to fresh air and keep at rest in a position comfortable for breathing. Immediately call a poison center or doctor/physician.
Symptoms: Toxic if inhaled. Danger of serious damage to health by prolonged exposure through inhalation.
Rinse skin with water/shower. Remove/take off immediately all contaminated clothing. Immediately call a poison center or doctor/physician. Wash with plenty of soap and water. Wash contaminated clothing before reuse.
Symptoms: Repeated exposure to this material can result in absorption through skin causing significant health hazard. Toxic in contact with skin.
Remove contact lenses, if present and easy to do. Continue rinsing. Rinse cautiously with water for several minutes. Obtain medical attention if pain, blinking or redness persists.
Rinse mouth. Do NOT induce vomiting. Obtain emergency medical attention. Immediately call a poison center or doctor/physician.
Symptoms: Toxic if swallowed. Swallowing a small quantity of this material will result in serious health hazard.
Immediate Medical Attention
Immediately call a poison center or doctor/physician.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Foam. Dry powder. Carbon dioxide. Water spray. Sand.
Do not use a heavy water stream.
Highly flammable liquid and vapour. May form flammable/explosive vapour-air mixture.
Use water spray or fog for cooling exposed containers. Exercise caution when fighting any chemical fire.
Firefighter Protection
Do not enter fire area without proper protective equipment, including respiratory protection.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Evacuate unnecessary personnel. Ventilate area.
Prevent entry to sewers and public waters.
Soak up spills with inert solids as soon as possible. Collect spillage.
Materials: inert solids
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Wash hands and other exposed areas with mild soap and water before eating, drinking or smoking and when leaving work. Provide good ventilation in process area to prevent formation of vapour. No open flames. No smoking. Use only non-sparking tools. Use only outdoors or in a well-ventilated area. Avoid breathing dust/fume/gas/mist/vapours/spray. Do not breathe dust/fume/gas/mist/vapours/spray.
Keep only in the original container in a cool, well ventilated place away from direct (sun)light. Keep in fireproof place. Keep container tightly closed. Do not freeze. Do not use after expiry date.
Do not eat, drink or smoke when using this product. Wash hands, forearms and face thoroughly after handling.
No open flames. No smoking. Use only non-sparking tools.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Use adequate ventilation! Handle in accordance with good industrial hygiene and safety. Avoid all unnecessary exposure.
Wear protective gloves. Gloves must be inspected prior to use. Use proper glove removal technique (without touching glove's outer surface) to avoid skin contact with this product. Dispose of contaminated gloves after use in accordance with applicable laws and good laboratory practices. Wash and dry hands. The selected protective gloves have to meet specifications of regulation EU 2016/425 and the standard EN374.
Face shield and safety glasses. Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166 (EU).
Wear appropriate mask. Where risk assessment shows air-purifying respirators are appropriate use a full-face respirator with multi-purpose combination (US) or type ABEK (EN 14387) respirator cartridges as a backup to engineering controls. If the respirator is the sole means of protection, use a full-face supplied air respirator. Use respirators and components tested and approved under appropriate government standards such as NIOSH (US) or CEN (EU).
Wear fire/flame resistant/retardant clothing. Complete suit protecting against chemicals, flame retardant antistatic protective clothing. The type of protection must be selected according to the concentration and volume of the dangerous substance at the specific workplace.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable after transport (max. 5 days) at elevated temperatures (≤37°C). Stable for 12 months after date of manufacture.
No additional information available
May form flammable/explosive vapour-air mixture.
elevated temperatures (>37°C)
Strong acids. Strong bases.
Fume. Carbon monoxide. Carbon dioxide. May release flammable gases.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 1230
- Shipping Name
- Methanol
- Transport Class
- 3 (6.1)
- Packing Group
- II
279
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for LeucoScreen Plus Reagent 1?
The signal word is danger.
What is the physical form of LeucoScreen Plus Reagent 1?
LeucoScreen Plus Reagent 1 is a liquid with colourless. color. It has characteristic. odor.
What is the solubility of LeucoScreen Plus Reagent 1?
Not available
What is LeucoScreen Plus Reagent 1 used for?
For professional use only. LeucoScreen Plus is a histochemical kit for the determination of peroxidase-positive white blood cells in human semen.
What are the hazard statements for LeucoScreen Plus Reagent 1?
This substance has 3 hazard statements:
- H225: Highly flammable liquid and vapour
- H301 + H311 + H331: Toxic if swallowed, in contact with skin or if inhaled
- H370: Causes damage to organs
What is the melting point of LeucoScreen Plus Reagent 1?
The melting point is Not available and the boiling point is Not available.