Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Castolin Flux 1802 N Atmosin
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Brazing flux
Manufacturers & Suppliers
Castolin Eutectic Limited
UNIT 3, OAK TREE PARK GB-B98 9NW REDDITCH, WORC'S.
+44 (0) 1527 5822 00
Castolin Eutectic GmbH
Gutenbergstrasse 10 D-65830 Kriftel
+49 (0) 6192 403 0
Emergency Contacts
NHS
111
NHS 24
111
GBK GmbH
+49 (0) 6132 / 84463
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS05
GHS07
GHS08
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Potassium pentaborate EC: 234-371-7 | 11128-29-3 | 10 - 50% | Yes |
| potassium fluoride EC: 232-151-5 | 7789-23-3 | 10 - 50% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Take affected person into fresh air.
In case of contact with skin wash off immediately with plenty of water.
In case of contact with eyes rinse thoroughly with plenty of water.
Rinse the mouth. Give the patient plenty of milk or other calcium source, e.g. calcium gluconate if available. Do not induce vomiting.
Immediate Medical Attention
Consult a physician if necessary (inhalation, skin). Seek medical advice (eyes). Take the patient to hospital (ingestion).
Medical Treatment
As soon as possible, take phials of calcium chloride and seek hospital.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use fire fighting measures that suit the environment and products stored.
In case of fire formation of dangerous gases possible. Hydrogen fluoride (HF), Fluorides. Hydrogen fluoride is liberated on heating at high temperatures in the presence of water vapor.
Firefighter Protection
In case of fire, wear suitable respiratory equipment with positive air supply.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Remove persons to safety.
Do not discharge into the drains or bodies of water.
Shovel into suitable container for disposal.
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Use only in well-ventilated areas. Avoid contact with eyes, skin or mucous membrane. Do not breathe vapours/dust. ANSI Z49.1 Safety in Welding, Cutting and allied processes.
Keep container dry and tightly closed. Keep in closed original container.
When using do not eat, drink or smoke.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Provide appropriate exhaust ventilation at machinery and at places where dust or smoke can be generated.
Use protective gloves for welders (DIN 4841-4). Glove material specification [make/type, thickness, permeation time/life, wetting resistance]: Butyl latex, 0,7 mm, 480 min., 60 min., i.e. protective glove made by www.kcl.de. Requirements can vary as a function of the use. Therefore it is necessary to adhere additionally to the recommendations given by the manufacturer of protective gloves. This recommendation refers exclusively to the chemical compatibility and the lab test conforming to EN 374 carried out under lab conditions.
Safety goggles with side protection (EN 166).
Use suitable breathing apparatus if there is inadequate ventilation. Multi-purpose filter ABEK/P3
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under normal conditions.
No data available
No data available
No data available
Strong acids
hydrogen fluoride
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Castolin Flux 1802 N Atmosin?
The signal word is danger.
What is the physical form of Castolin Flux 1802 N Atmosin?
Castolin Flux 1802 N Atmosin is a powder . It has odourless odor.
What is Castolin Flux 1802 N Atmosin used for?
Brazing flux
What are the hazard statements for Castolin Flux 1802 N Atmosin?
This substance has 3 hazard statements:
- H302 + H312 + H332: Harmful if swallowed, in contact with skin or if inhaled.
- H318: Causes serious eye damage.
- H361d: Suspected of damaging the unborn child.
What is the melting point of Castolin Flux 1802 N Atmosin?
The melting point is ~550 - 750 °C and the boiling point is n.a..