NextSDS Logo
Safety Data Sheet EN

Kaiflex® Spezialkleber 414 / Special Adhesive 414

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Kaiflex® Spezialkleber 414 / Special Adhesive 414

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Adhesives

Uses advised against

Restricted to professional users.

Manufacturers & Suppliers

Kaimann GmbH logo

Kaimann GmbH

manufacturer

Hansastr. 2-5; D - 33161 Hövelhof

+49 (0) 5257-9850-0

http://www.kaimann.com

Emergency Contacts

NHS

111

NHS 24

111

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Flam. Liq. Cat. 2 H225
Aquatic Chronic Cat. 2 H411
Skin Irrit. Cat. 2 H315
Eye Irrit. Cat. 2 H319
STOT SE Cat. 3 H336

GHS Pictograms

GHS02 - Flammable

GHS02

GHS07 - Health hazard

GHS07

GHS09 - Environmental hazard

GHS09

Hazard Statements

H225 Highly flammable liquid and vapour.
H315 Causes skin irritation.
H319 Causes serious eye irritation.
H336 May cause drowsiness or dizziness.
H411 Toxic to aquatic life with long lasting effects.

Precautionary Statements

P210 Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
P241 Use explosion-proof [electrical/ventilating/lighting] equipment.
P303 + P361 + P353 IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water [or shower].
P305 + P351 + P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
P403 + P233 Store in a well-ventilated place. Keep container tightly closed.
P501 Dispose of contents / container to approved waste disposal or recycling in accordance with national regulations.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Hydrocarbons, C6-C7, isoalkanes, cyclics, < 5 % n-hexane EC: 926-605-8 64742-49-0 35 - 50% Yes
ethyl acetate EC: 205-500-4 141-78-6 25 - 35% Yes
cyclohexane EC: 203-806-2 110-82-7 10 - 15% Yes
acetone EC: 200-662-2 67-64-1 2.5 - 5% Yes
n-hexane EC: 203-777-6 110-54-3 1 - 2.5% Yes
Rosin EC: 232-475-7 8050-09-7 0.1 - 0.5% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Supply fresh air.

Skin contact

Instantly wash with water and soap and rinse thoroughly.

Eye contact

Rinse opened eye for several minutes under running water.

Immediate Medical Attention

Consult physician in case of symptoms (inhalation, swallowing, or persistent eye symptoms).

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Foam extinguishing agent, CO2, extinguishing powder or water jet. Fight larger fire with alcohol-resistant foam.

Unsuitable media

Water with a full water jet.

Specific hazards

Can be released in case of fire: Carbon monoxide (CO)

Instructions

Do not inhale explosion gases or combustion gases.

Firefighter Protection

Wear self-contained breathing apparatus.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Environmental

Do not allow product to reach sewage system or water bodies. Prevent material from reaching sewage system, holes and cellars. Prevent from spreading (e.g. by damming-in or oil barriers).

Cleanup methods

Absorb with liquid-binding material (sand, diatomite, acid binders, universal binders, sawdust).

Materials: sand, diatomite, acid binders, universal binders, sawdust

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Open and handle container with care.

Storage

Store in cool, dry place in tightly closed containers.

Fire prevention

Keep ignition sources away - Do not smoke. Protect against electrostatic charges.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

No further data; see item 7. Additional information about design of technical systems: No further data; see item 7.

Hands

Impervious gloves (EN 374). Material of gloves: Recommended thickness of the material: ≥ 0.7 mm, LLDPE gloves. Penetration time of glove material: Value for the permeation: Level ≤ 1. Gloves made of the following material are suitable for the permanent contact with this material in work areas which do not have an above-average risk of injury (e.g. laboratories): LLDPE gloves. For the permanent contact gloves made of the following materials are suitable: LLDPE gloves. For permanent contact of max. 15 minutes, gloves made of the following materials are suitable: Butyl rubber, BR. To protect against splashing, gloves made of the following materials are suitable: Chloroprene rubber, CR. Not suitable are gloves made of the following materials: Leather gloves, Strong gloves.

Eyes

Safety glasses recommended during refilling and spraying. Safety glasses.

Respiratory

Use breathing protection in case of insufficient ventilation (EN 14387). Short term filter device: Filter AX (boining point < 61 °C); Filter A (boiling point > 60 °C). Only when applied by spray methods, if no adequate extraction system is in place (EN 149). Filter A/P2

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Fluid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
---
Colour
According to product specification
Colour Intensity
---
Form
Fluid
Odor
Characteristic
Odor Threshold
Not determined.
Ph
Not determined.
Melting Point
Not determined
Boiling Point
60 °C
Flash Point
-21 °C
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
Not determined.
Vapor Pressure
110 hPa
Vapor Density
Not determined.
Relative Density
Not determined.
Bulk Density
---
Density
0.85 g/cm³
Flammability
---
Upper Explosive Limit
11.5 Vol %
Lower Explosive Limit
1.1 Vol %
Explosive Limits
---
Auto Ignition Temperature
>200 °C
Decomposition Temperature
Not determined.
Solubility
---
Partition Coefficient
Not determined.
Solubility In Water
Not miscible or difficult to mix
Solubility In Fat
---
Molecular Weight
---
Voc Content
81.02 %
Metal Corrosion
---
Dynamic Viscosity
600 mPas
Kinematic Viscosity
457.17 mm²/s
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

No decomposition if used according to specifications.

Reactivity

No further relevant information available.

Hazardous reactions

Forms explosive gas mixture with air; Develops readily flammable gases / fumes; Used empty containers may contain product gases which form explosive mixtures with air; Can form explosive mixtures in air if heated above flash point and/or when sprayed or atomised

Avoid

No decomposition if used according to specifications.

Incompatible

strong acids and alkali

Decomposition

Hydrocarbons, Inflammable gases/vapours, Carbon monoxide and carbon dioxide

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
UN1133
Shipping Name
ADHESIVES
Transport Class
3
Packing Group
II
ADR

Warning: Flammable liquids.

IMDG

Warning: Flammable liquids.

IATA

Warning: Flammable liquids.

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Kaiflex® Spezialkleber 414 / Special Adhesive 414?

The signal word is danger.

What is the physical form of Kaiflex® Spezialkleber 414 / Special Adhesive 414?

Kaiflex® Spezialkleber 414 / Special Adhesive 414 is a fluid with according to product specification color. It has characteristic odor.

What is Kaiflex® Spezialkleber 414 / Special Adhesive 414 used for?

Adhesives

What are the hazard statements for Kaiflex® Spezialkleber 414 / Special Adhesive 414?

This substance has 5 hazard statements:

  • H225: Highly flammable liquid and vapour.
  • H315: Causes skin irritation.
  • H319: Causes serious eye irritation.
  • H336: May cause drowsiness or dizziness.
  • H411: Toxic to aquatic life with long lasting effects.

What is the melting point of Kaiflex® Spezialkleber 414 / Special Adhesive 414?

The melting point is Not determined and the boiling point is 60 °C.