Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Kaiflex K 414 glue
Regulatory Identifiers
- CAS Number
- N/A
- UFI Code
- CV0S-7H8Q-HC0K-V3N5
Identified Uses
Adhesive. For professional users only.
Uses advised against
Sealant.
Manufacturers & Suppliers
Kaimann GmbH
manufacturer
Hansastrae 2-5 D-33161 Hvelhof
+49 (0) 5257-9850-0
Emergency Contacts
Advice Center for Poison Symptoms and Embryo Toxicology (Emergency Phone Line Berlin / Giftnotruf Berlin)
+49 (0) 30 -1 92 40
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS02
GHS07
GHS09
Hazard Statements
Precautionary Statements
Manage your Safety Data Sheets
Organize and access chemical safety data with ease
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
Adhesive
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| HYDROCARBON, C6-C7, isoalkanes, cyclic, <5% n-hexane EC: 926-605-8 | 64742-49-0 | 35 - 50% | Yes |
| Ethyl acetaat EC: 205-500-4 | 141-78-6 | 25 - 35% | Yes |
| CYCLOHEXAN EC: 203-806-2 | 110-82-7 | 10 - 15% | Yes |
| Acetone a.r. EC: 200-662-2 | 67-64-1 | 2.5 - 5% | Yes |
| n-HEXAN EC: 203-777-6 | 110-54-3 | 1 - 2.5% | Yes |
| ROSIN EC: 232-475-7 | 8050-09-7 | 0.1 - 0.5% | Yes |
If any R-phrases (risk-phrases) are listed, please refer for the exact wording to section 16. Contains < 0.1 % benzene (Note P).
First Aid Measures
Emergency procedures for chemical exposure incidents
In case of unconsciousness bring patient into stable side position for transport. Supply fresh air; consult physician in case of symptoms.
Instantly wash with water and soap and rinse thoroughly.
Rinse opened eye for several minutes under running water. If symptoms persist, consult physician.
In case of persistent symptoms consult physician.
Immediate Medical Attention
If swallowed or in case of vomiting, danger of entering the lungs.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
The data for this section has not been processed yet.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
The data for this section has not been processed yet.
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
The data for this section has not been processed yet.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
No further data; see item 7.
In case of direct contact with the liquid material (e.g. during cleaning work): Gloves. Otherwise, no hand protection is necessary. Impermeable gloves (EN 374). Recommended thickness of the material: 0.7 mm. LLDPE gloves. Penetration time of glove material: Value for the permeation: Level 1. Gloves made of the following material are suitable for the permanent contact with this material in work areas which do not have an above-average risk of injury (e.g. laboratories): LLDPE gloves. For the permanent contact gloves made of the following materials are suitable: LLDPE gloves. For permanent contact of max. 15 minutes, gloves made of the following materials are suitable: Butyl rubber, BR. To protect against splashing, gloves made of the following materials are suitable: Chloroprene rubber, CR. Not suitable are gloves made of the following materials: Gloves made of leather. Gloves made of thick fabric.
Safety glasses recommended during refilling and spraying. Safety glasses.
In case of insufficient ventilation, use respiratory protection (EN 14387). Short-term filter device: Filter AX (boiling point < 61 C); Filter A (boiling point > 60 C). Only when spraying without adequate exhaust ventilation (EN 149). Filter A/P2
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
The data for this section has not been processed yet.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- UN 1133
- Shipping Name
- ADHESIVES
- Transport Class
- 3 Flammable liquids
- Packing Group
- II
Warning: Flammable liquids.
Warning: Flammable liquids.
Warning: Flammable liquids.
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Kaiflex K 414 glue?
The signal word is danger.
What is the physical form of Kaiflex K 414 glue?
Kaiflex K 414 glue is a fluid with according to product specification color. It has characteristic odor.
What is the solubility of Kaiflex K 414 glue?
Not miscible or difficult to mix.
What is Kaiflex K 414 glue used for?
Adhesive. For professional users only.
What are the hazard statements for Kaiflex K 414 glue?
This substance has 5 hazard statements:
- H225: Highly flammable liquid and vapour.
- H315: Causes skin irritation.
- H319: Causes serious eye irritation.
- H336: May cause drowsiness or dizziness.
- H411: Toxic to aquatic life with long lasting effects.
What is the melting point of Kaiflex K 414 glue?
The melting point is Not determined. and the boiling point is 60 C.