Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Hydrochloric acid 1M
- Product Code
- J/4320/15, J/4320/24, J/4320/17, J/4320/21, J/4320/99
- Synonyms
- Muriatic acid; Hydrogen chloride; HCl
Regulatory Identifiers
- CAS Number
- N/A
- UFI Code
- EQCA-53ER-9X05-HFT1
Identified Uses
Laboratory chemicals.
Uses advised against
No Information available
Manufacturers & Suppliers
Fisher Scientific UK
national supplier
Bishop Meadow Road, Loughborough, Leicestershire LE11 5RG, United Kingdom
Thermo Fisher Scientific
national supplier
Janssen Pharmaceuticalaan 3a, 2440 Geel, Belgium
Emergency Contacts
Emergency Contact
01509 231166
Chemtrec US
(800) 424-9300
Chemtrec EU
001-703-527-3887
National Poisons Information Centre (NPIC)
01 809 2166
8am-10pm, 7 days a week
Emergency Contact
+356 2395 2000
Emergency Contact
+357 2240 5611
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS05
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove to fresh air. If not breathing, give artificial respiration. Get medical attention if symptoms occur.
Wash off immediately with plenty of water for at least 15 minutes. If skin irritation persists, call a physician.
Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. Get medical attention.
Clean mouth with water and drink afterwards plenty of water.
Immediate Medical Attention
Get medical attention if symptoms occur.
Medical Treatment
Treat symptomatically.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Substance is nonflammable; use agent most appropriate to extinguish surrounding fire.
No information available.
Non-combustible, substance itself does not burn but may decompose upon heating to produce corrosive and/or toxic fumes.
Firefighter Protection
As in any fire, wear self-contained breathing apparatus pressure-demand, MSHA/NIOSH (approved or equivalent) and full protective gear.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Use personal protective equipment as required. Ensure adequate ventilation.
Should not be released into the environment.
Soak up with inert absorbent material.
Materials: inert absorbent material
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Wear personal protective equipment/face protection. Avoid ingestion and inhalation. Do not get in eyes, on skin, or on clothing.
Keep containers tightly closed in a dry, cool and well-ventilated place. Keep only in the original container.
Handle in accordance with good industrial hygiene and safety practice. Keep away from food, drink and animal feeding stuffs. Do not eat, drink or smoke when using this product. Remove and wash contaminated clothing and gloves, including the inside, before re-use. Wash hands before breaks and after work.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Ensure adequate ventilation, especially in confined areas. Ensure that eyewash stations and safety showers are close to the workstation location. Wherever possible, engineering control measures such as the isolation or enclosure of the process, the introduction of process or equipment changes to minimise release or contact, and the use of properly designed ventilation systems, should be adopted to control hazardous materials at source
Protective gloves. Glove material: Butyl rubber (> 480 minutes, 0.20 mm, Level 6, EN374-3), Neoprene (> 480 minutes, 0.35 mm, EN 374), Nitrile rubber (> 480 minutes, 0.45 mm), PVC (> 480 minutes, 0.18 mm), Viton (R) (> 480 minutes, 0.30 mm). As tested under EN374-3 Determination of Resistance to Permeation by Chemicals.
Goggles (European standard - EN 166)
Follow the OSHA respirator regulations found in 29 CFR 1910.134 or European Standard EN 149. Use a NIOSH/MSHA or European Standard EN 149 approved respirator if exposure limits are exceeded or if irritation or other symptoms are experienced. To protect the wearer, respiratory protective equipment must be the correct fit and be used and maintained properly. Large scale/emergency use: Use a NIOSH/MSHA or European Standard EN 136 approved respirator if exposure limits are exceeded or if irritation or other symptoms are experienced. Recommended Filter type: Particulates filter conforming to EN 143. Small scale/Laboratory use: No personal respiratory protective equipment normally required. When RPE is used a face piece Fit Test should be conducted.
Wear appropriate protective gloves and clothing to prevent skin exposure. Inspect gloves before use. Please observe the instructions regarding permeability and breakthrough time which are provided by the supplier of the gloves. (Refer to manufacturer/supplier for information) Ensure gloves are suitable for the task: Chemical compatability, Dexterity, Operational conditions, User susceptibility, e.g. sensitisation effects, also take into consideration the specific local conditions under which the product is used, such as the danger of cuts, abrasion. Remove gloves with care avoiding skin contamination.
No information available.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under normal conditions.
None known, based on information available
None under normal processing. Hazardous polymerization does not occur.
Incompatible products. Excess heat.
Strong oxidizing agents. Reducing Agent. Bases. Metals.
Hydrogen chloride gas.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- UN1789
- Shipping Name
- HYDROCHLORIC ACID, SOLUTION
- Transport Class
- 8
- Packing Group
- III
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What other names is Hydrochloric acid 1M known by?
Hydrochloric acid 1M is also known as: Muriatic acid; Hydrogen chloride; HCl
What is the hazard signal word for Hydrochloric acid 1M?
The signal word is warning.
What is the physical form of Hydrochloric acid 1M?
Hydrochloric acid 1M is a liquid appearing as colorless . It has odorless odor.
What is the solubility of Hydrochloric acid 1M?
No information available
What is Hydrochloric acid 1M used for?
Laboratory chemicals.
What are the hazard statements for Hydrochloric acid 1M?
This substance has 1 hazard statement:
- H290: May be corrosive to metals
What is the melting point of Hydrochloric acid 1M?
The melting point is No data available and the boiling point is 100 - 103 °C / 212 - 217.4 °F.