Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Boric acid 99.9999 Suprapur®
- Product Code
- 1.00765
- Chemical Name
- Boric acid
Regulatory Identifiers
- CAS Number
- 10043-35-3 Check regulations →
- REACH No.
- 01-2119486683-25-XXXX
Identified Uses
Reagent for analysis
Manufacturers & Suppliers
Sigma-Aldrich Chemie GmbH
manufacturer
Eschenstrasse 5, D-82024 TAUFKIRCHEN
+49 (0)89 6513-1130
Emergency Contacts
CHEMTREC Deutschland
0800 181 7059
CHEMTREC weltweit
+49 (0)696 43508409
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS08
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| boric acid EC: 233-139-2 | 10043-35-3 | 90 - 100% | No |
First Aid Measures
Emergency procedures for chemical exposure incidents
After inhalation: fresh air. Call in physician.
Take off immediately all contaminated clothing. Rinse skin with water/ shower. Consult a physician.
After eye contact: rinse out with plenty of water. Call in ophthalmologist. Remove contact lenses.
After swallowing: immediately make victim drink water (two glasses at most). Consult a physician.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use extinguishing measures that are appropriate to local circumstances and the surrounding environment.
For this substance/mixture no limitations of extinguishing agents are given.
Not combustible. Fire may cause evolution of: boron compounds. Ambient fire may liberate hazardous vapours.
Firefighter Protection
Stay in danger area only with self-contained breathing apparatus. Prevent skin contact by keeping a safe distance or by wearing suitable protective clothing.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Avoid inhalation of dusts. Avoid substance contact. Ensure adequate ventilation. Evacuate the danger area, observe emergency procedures, consult an expert.
Do not let product enter drains.
Cover drains. Collect, bind, and pump off spills. Observe possible material restrictions (see sections 7 and 10). Take up carefully. Dispose of properly. Clean up affected area.
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Work under hood. Do not inhale substance/mixture.
Tightly closed. Dry. Keep in a well-ventilated place. Keep locked up or in an area accessible only to qualified or authorised persons.
Immediately change contaminated clothing. Apply preventive skin protection. Wash hands and face after working with substance.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Material : Nitrile rubber; Break through time : 480 min; Glove thickness : 0,11 mm; Protective index : Full contact; Manufacturer : KCL 741 Dermatril® L. Material : Nitrile rubber; Break through time : 480 min; Glove thickness : 0,11 mm; Protective index : Splash contact; Manufacturer : KCL 741 Dermatril® L. Remarks : This recommendation applies only to the product stated in the safety data sheet, supplied by us and for the designated use. When dissolving in or mixing with other substances and under conditions deviating from those stated in EN 16523-1 please contact the supplier of CE-approved gloves (e.g. KCL GmbH, D-36124 Eichenzell, Internet: www.kcl.de).
Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU). Safety glasses
required when dusts are generated. Our recommendations on filtering respiratory protection are based on the following standards: DIN EN 143, DIN 14387 and other accompanying standards relating to the used respiratory protection system. Recommended Filter type : Filter type P3. The entrepreneur has to ensure that maintenance, cleaning and testing of respiratory protective devices are carried out according to the instructions of the producer. These measures have to be properly documented.
protective clothing
Do not let product enter drains.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
The product is chemically stable under standard ambient conditions (room temperature).
No data available
Risk of explosion with: Acetic anhydride. Violent reactions possible with: strong oxidising agents, Bases
no information available
Acetic anhydride, strong oxidising agents, Bases
In the event of fire: see section 5
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Boric acid 99.9999 Suprapur®?
The signal word is danger.
What is the physical form of Boric acid 99.9999 Suprapur®?
Boric acid 99.9999 Suprapur® is a solid (20 °c, 1.013 hpa) with white color. It has odourless odor.
What is Boric acid 99.9999 Suprapur® used for?
Reagent for analysis
What are the hazard statements for Boric acid 99.9999 Suprapur®?
This substance has 1 hazard statement:
- H360: H360FD May damage fertility. May damage the unborn child.
What is the melting point of Boric acid 99.9999 Suprapur®?
The melting point is 100 °C and the boiling point is No data available.