NextSDS Logo
Safety Data Sheet EN

L-Aspartic acid

CAS 56-84-8

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
L-Aspartic acid
Product Code
A9256
Chemical Name
L-Aspartic acid

Regulatory Identifiers

CAS Number
56-84-8 Check regulations →
REACH No.
01-2119966139-27-XXXX

Identified Uses

Laboratory chemicals, Manufacture of substances

Manufacturers & Suppliers

S

Sigma

manufacturer

S

Sigma-Aldrich Chemie GmbH

manufacturer

Eschenstrasse 5, D-82024 TAUFKIRCHEN

+49 (0)89 6513-1130

Emergency Contacts

CHEMTREC Deutschland

0800 181 7059

CHEMTREC weltweit

+49 (0)696 43508409

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type substance
Chemical Name CAS Number Concentration Hazardous
(<I>S</>)-(+)-Aminosuccinic acid EC: 200-291-6 --- --- No

Notes

Remarks : No hazardous ingredients

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

After inhalation: fresh air.

Skin contact

In case of skin contact: Take off immediately all contaminated clothing. Rinse skin with water/ shower.

Eye contact

After eye contact: rinse out with plenty of water. Remove contact lenses.

Ingestion

After swallowing: make victim drink water (two glasses at most). Consult doctor if feeling unwell.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Water, Foam, Carbon dioxide (CO2), Dry powder

Unsuitable media

For this substance/mixture no limitations of extinguishing agents are given.

Specific hazards

Combustible. Development of hazardous combustion gases or vapours possible in the event of fire.

Instructions

Suppress (knock down) gases/vapours/mists with a water spray jet.

Firefighter Protection

In the event of fire, wear self-contained breathing apparatus.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Avoid inhalation of dusts. Evacuate the danger area, observe emergency procedures, consult an expert.

Environmental

Do not let product enter drains.

Cleanup methods

Take up dry. Dispose of properly. Clean up affected area. Avoid generation of dusts.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Change contaminated clothing. Wash hands after working with substance. For precautions see section 2.2.

Storage

Tightly closed. Dry.

Hygiene

Change contaminated clothing. Wash hands after working with substance.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Hands

Material : Nitrile rubber, Break through time : 480 min, Glove thickness : 0,11 mm, Protective index : Full contact / Splash contact, Manufacturer : KCL 741 Dermatril® L. Remarks : This recommendation applies only to the product stated in the safety data sheet, supplied by us and for the designated use. When dissolving in or mixing with other substances and under conditions deviating from those stated in EN 16523-1 please contact the supplier of CE-approved gloves (e.g. KCL GmbH, D-36124 Eichenzell, Internet: www.kcl.de).

Eyes

Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU). Safety glasses

Respiratory

required when dusts are generated. Our recommendations on filtering respiratory protection are based on the following standards: DIN EN 143, DIN 14387 and other accompanying standards relating to the used respiratory protection system. Recommended Filter : Filter type P1. The entrepreneur has to ensure that maintenance, cleaning and testing of respiratory protective devices are carried out according to the instructions of the producer. These measures have to be properly documented.

Environmental

Do not let product enter drains.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
solid
Physical State Data
solid
State Under Standard Conditions
---
Appearance
---
Colour
white
Colour Intensity
---
Form
powder
Odor
No data available
Odor Threshold
---
Ph
3,03
Melting Point
> 300 °C
Boiling Point
No data available
Flash Point
Not applicable
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
No data available
Vapor Pressure
No data available
Vapor Density
---
Relative Density
No data available
Bulk Density
---
Density
1,66 g/cm3 (13 °C)
Flammability
Method: Test N.1: Test method for readily combustible solids Remarks: The product is not flammable.
Upper Explosive Limit
No data available
Lower Explosive Limit
No data available
Explosive Limits
---
Auto Ignition Temperature
No data available
Decomposition Temperature
No data available
Solubility
---
Partition Coefficient
No data available
Solubility In Water
4,2 g/l (20 °C) soluble
Solubility In Fat
---
Molecular Weight
133,10 g/mol
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
No data available
Kinematic Viscosity
No data available
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

The product is chemically stable under standard ambient conditions (room temperature).

Reactivity

The following applies in general to flammable organic substances and mixtures: in correspondingly fine distribution, when whirled up a dust explosion potential may generally be assumed.

Hazardous reactions

Violent reactions possible with: Strong acids, Strong bases, Strong oxidizing agents, Nitric acid

Avoid

no information available

Incompatible

No data available

Decomposition

In the event of fire: see section 5

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for L-Aspartic acid?

The signal word is no signal word.

What is the physical form of L-Aspartic acid?

L-Aspartic acid is a solid with white color. It has no data available odor.

What is L-Aspartic acid used for?

Laboratory chemicals, Manufacture of substances

What is the melting point of L-Aspartic acid?

The melting point is > 300 °C and the boiling point is No data available.