NextSDS Logo
Safety Data Sheet EN

L(+)-Ascorbic acid

CAS 50-81-7
EC 200-066-2

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
L(+)-Ascorbic acid
Product Code
105020000; 105021000; 105025000
Chemical Name
L(+)-Ascorbic acid
Synonyms
Vitamin C

Regulatory Identifiers

CAS Number
50-81-7 Check regulations →
EC Number
200-066-2 Check regulations →

Identified Uses

Laboratory chemicals.

Uses advised against

No Information available

Manufacturers & Suppliers

F

Fisher Scientific UK

distributor

Bishop Meadow Road, Loughborough, Leicestershire LE11 5RG, United Kingdom

T

Thermo Fisher Scientific

distributor

Janssen Pharmaceuticalaan 3a, 2440 Geel, Belgium

Emergency Contacts

Emergency Contact

001-800-227-6701

Emergency Contact

+32 14 57 52 11

Emergency Contact

001-201-796-7100

Emergency Contact

+32 14 57 52 99

CHEMTREC

001-800-424-9300

CHEMTREC

001-703-527-3887

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type substance
Chemical Name CAS Number Concentration Hazardous
L-Ascorbic acid EC: 200-066-2 50-81-7 --- No

Full text of Hazard Statements: see section 16

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove to fresh air. If breathing is difficult, give oxygen.

Skin contact

Wash off immediately with plenty of water for at least 15 minutes.

Eye contact

Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes.

Ingestion

Rinse mouth. Do NOT induce vomiting.

Immediate Medical Attention

Get medical attention.

Medical Treatment

Treat symptomatically.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Water spray, carbon dioxide (CO2), dry chemical, alcohol-resistant foam.

Unsuitable media

No information available.

Specific hazards

Thermal decomposition can lead to release of irritating gases and vapors. Keep product and empty container away from heat and sources of ignition.

Firefighter Protection

As in any fire, wear self-contained breathing apparatus pressure-demand, MSHA/NIOSH (approved or equivalent) and full protective gear.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Use personal protective equipment as required.

Environmental

Avoid release to the environment.

Cleanup methods

Sweep up and shovel into suitable containers for disposal.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Wear personal protective equipment/face protection. Ensure adequate ventilation. Avoid dust formation. Avoid contact with skin, eyes or clothing. Avoid ingestion and inhalation.

Storage

Keep in a dry, cool and well-ventilated place. Keep container tightly closed. Protect from direct sunlight. Store under an inert atmosphere.

Hygiene

Handle in accordance with good industrial hygiene and safety practice. Keep away from food, drink and animal feeding stuffs. Do not eat, drink or smoke when using this product. Remove and wash contaminated clothing and gloves, including the inside, before re-use. Wash hands before breaks and after work.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Ensure adequate ventilation, especially in confined areas. Ensure that eyewash stations and safety showers are close to the workstation location.

Hands

Protective gloves. Glove material: Natural rubber, Butyl rubber, Nitrile rubber, Neoprene, PVC. Breakthrough time: See manufacturers recommendations. EU standard: EN 374. Glove comments: (minimum requirement).

Eyes

Wear safety glasses with side shields (or goggles) (European standard - EN 166)

Respiratory

No protective equipment is needed under normal use conditions. Large scale/emergency use: Use a NIOSH/MSHA or European Standard EN 136 approved respirator if exposure limits are exceeded or if irritation or other symptoms are experienced. Recommended Filter type: Particle filter. Small scale/Laboratory use: Maintain adequate ventilation. Recommended half mask:- Valve filtering: EN405; or; Half mask: EN140; plus filter, EN 141

Skin/Body

Wear appropriate protective gloves and clothing to prevent skin exposure. Inspect gloves before use. Please observe the instructions regarding permeability and breakthrough time which are provided by the supplier of the gloves. (Refer to manufacturer/supplier for information) Ensure gloves are suitable for the task: Chemical compatibility, Dexterity, Operational conditions, User susceptibility, e.g. sensitisation effects, also take into consideration the specific local conditions under which the product is used, such as the danger of cuts, abrasion. Remove gloves with care avoiding skin contamination.

Environmental

No information available.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Solid
Physical State Data
solid
State Under Standard Conditions
---
Appearance
Off-white
Colour
---
Colour Intensity
---
Form
---
Odor
Odorless
Odor Threshold
No data available
Ph
2.1-2.6, 5% aq. soln
Melting Point
190 - 192 °C / 374 - 377.6 °F
Boiling Point
No information available
Flash Point
No information available, Method - No information available
Freezing Point
---
Softening Point
No data available
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
Not applicable - Solid
Vapor Pressure
No data available
Vapor Density
Not applicable
Relative Density
---
Bulk Density
---
Density
---
Flammability
No information available
Upper Explosive Limit
---
Lower Explosive Limit
---
Explosive Limits
---
Auto Ignition Temperature
380 °C / 716 °F
Decomposition Temperature
No data available
Solubility
---
Partition Coefficient
---
Solubility In Water
333 g/L (20°C)
Solubility In Fat
---
Molecular Weight
176.13
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
---
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under normal conditions.

Reactivity

None known, based on information available

Hazardous reactions

Hazardous polymerization does not occur. No information available.

Avoid

Air sensitive. Light sensitive.

Incompatible

Strong oxidizing agents. Metals. copper.

Decomposition

Carbon monoxide (CO). Carbon dioxide (CO₂).

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What other names is L(+)-Ascorbic acid known by?

L(+)-Ascorbic acid is also known as: Vitamin C

What is the hazard signal word for L(+)-Ascorbic acid?

The signal word is no signal word.

What is the physical form of L(+)-Ascorbic acid?

L(+)-Ascorbic acid is a solid appearing as off-white . It has odorless odor.

What is L(+)-Ascorbic acid used for?

Laboratory chemicals.

What is the melting point of L(+)-Ascorbic acid?

The melting point is 190 - 192 °C / 374 - 377.6 °F and the boiling point is No information available.