NextSDS Logo
Safety Data Sheet EN

Ammonium acetate for analysis EMSURE® ACS, Reag. Ph Eur

CAS 631-61-8

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Ammonium acetate for analysis EMSURE® ACS, Reag. Ph Eur
Product Code
1.01116
Chemical Name
Ammonium acetate

Regulatory Identifiers

CAS Number
631-61-8 Check regulations →
REACH No.
01-2119828440-45-XXXX

Identified Uses

Reagent for analysis

Manufacturers & Suppliers

S

Sigma-Aldrich Chemie GmbH

manufacturer

Eschenstrasse 5, D-82024 TAUFKIRCHEN

+49 (0)89 6513-1130

Emergency Contacts

CHEMTREC Deutschland

0800 181 7059

CHEMTREC weltweit

+49 (0)696 43508409

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type substance

Formula : C2H4O2.H3N Molecular weight : 77,08 g/mol CAS-No. : 631-61-8 EC-No. : 211-162-9

Chemical Name CAS Number Concentration Hazardous
C2H4O2.H3N EC: 211-162-9 631-61-8 --- No

Notes

No components need to be disclosed according to the applicable regulations.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

After inhalation: fresh air.

Skin contact

In case of skin contact: Take off immediately all contaminated clothing. Rinse skin with water/ shower.

Eye contact

After eye contact: rinse out with plenty of water. Remove contact lenses.

Ingestion

After swallowing: make victim drink water (two glasses at most). Consult doctor if feeling unwell.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Water, Foam, Carbon dioxide (CO2), Dry powder

Unsuitable media

For this substance/mixture no limitations of extinguishing agents are given.

Specific hazards

Carbon oxides, Nitrogen oxides (NOx), Combustible. Fire may cause evolution of: nitrogen oxides. Development of hazardous combustion gases or vapours possible in the event of fire.

Instructions

Suppress (knock down) gases/vapors/mists with a water spray jet.

Firefighter Protection

In the event of fire, wear self-contained breathing apparatus.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Avoid inhalation of dusts. Evacuate the danger area, observe emergency procedures, consult an expert.

Environmental

Do not let product enter drains.

Cleanup methods

Take up dry. Clean up affected area.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

For precautions see section 2.2.

Storage

Tightly closed. Dry. Recommended storage temperature see product label.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Hands

Material: Nitrile rubber, Minimum layer thickness: 0,11 mm, Break through time: 480 min, Material tested: KCL 741 Dermatril® L

Eyes

Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU). Safety glasses

Respiratory

required when dusts are generated. Our recommendations on filtering respiratory protection are based on the following standards: DIN EN 143, DIN 14387 and other accompanying standards relating to the used respiratory protection system. Recommended Filter type: Filter type P1. The entrepreneur has to ensure that maintenance, cleaning and testing of respiratory protective devices are carried out according to the instructions of the producer. These measures have to be properly documented.

Environmental

Do not let product enter drains.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Flammability
---
Upper Explosive Limit
---
Softening Point
---
Appearance
---
Lower Explosive Limit
---
Relative Density
---
Cloud Point
---
Vapor Pressure
< 0,001 hPa
Metal Corrosion
---
Form
---
State Under Standard Conditions
---
Melting Point
114 °C
Colour Intensity
---
Evaporation Rate
---
Decomposition Temperature
---
Flash Point
Not applicable
Partition Coefficient
log Pow: -2,79 - (Lit.), Bioaccumulation is not expected.
Kinematic Viscosity
No data available
Colour
colorless
Ph
---
Vapor Density
---
Auto Ignition Temperature
---
Freezing Point
---
Crystallisation Point
---
Solubility In Water
---
Molecular Weight
---
Bulk Density
ca. 410 kg/m³
Explosive Limits
---
Physical State
solid
Density
1,17 g/cm³ at 20 °C
Voc Content
---
Boiling Point
Decomposes below the boiling point.
Solubility
---
Properties Status
---
Solubility In Fat
---
Odor
weakly of acetic acid
Odor Threshold
---
Relative Evaporation Rate
---
Solidification Point
---
Physical State Data
solid
Dynamic Viscosity
No data available
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

The product is chemically stable under standard ambient conditions (room temperature).

Reactivity

The following applies in general to flammable organic substances and mixtures: in correspondingly fine distribution, when whirled up a dust explosion potential may generally be assumed.

Hazardous reactions

Risk of explosion with: sodium hypochlorite, gold compounds. Violent reactions possible with: Strong acids, strong alkalis, Strong oxidizing agents.

Avoid

no information available

Incompatible

No data available

Decomposition

In the event of fire: see section 5

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Ammonium acetate for analysis EMSURE® ACS, Reag. Ph Eur?

The signal word is no signal word.

What is the physical form of Ammonium acetate for analysis EMSURE® ACS, Reag. Ph Eur?

Ammonium acetate for analysis EMSURE® ACS, Reag. Ph Eur is a solid with colorless color. It has weakly of acetic acid odor.

What is Ammonium acetate for analysis EMSURE® ACS, Reag. Ph Eur used for?

Reagent for analysis

What is the melting point of Ammonium acetate for analysis EMSURE® ACS, Reag. Ph Eur?

The melting point is 114 °C and the boiling point is Decomposes below the boiling point..