NextSDS Logo
Safety Data Sheet EN

Ammonium chloride for analysis EMSURE® ACS,ISO,Reag. Ph Eur

CAS 12125-02-9

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Ammonium chloride for analysis EMSURE® ACS,ISO,Reag. Ph Eur
Product Code
1.01145
Chemical Name
Ammonium chloride

Regulatory Identifiers

CAS Number
12125-02-9 Check regulations →
REACH No.
01-2119489385-24-XXXX

Identified Uses

Reagent for analysis

Manufacturers & Suppliers

S

Sigma-Aldrich Chemie GmbH

manufacturer

Eschenstrasse 5, D-82024 TAUFKIRCHEN

+49 (0)89 6513-1130

Emergency Contacts

CHEMTREC Deutschland

0800 181 7059

CHEMTREC weltweit

+49 (0)696 43508409

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified warning

Hazard Classifications

Acute Tox. Cat. 4 H302
Eye Irrit. Cat. 2 H319

GHS Pictograms

GHS07 - Health hazard

GHS07

Hazard Statements

H302 Harmful if swallowed.
H319 Causes serious eye irritation.

Precautionary Statements

P264 Wash skin thoroughly after handling.
P280 Wear eye protection/ face protection.
P301 + P312 IF SWALLOWED: Call a POISON CENTER/ doctor if you feel unwell.
P305 + P351 + P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
P337 + P313 If eye irritation persists: Get medical advice/ attention.
P501 Dispose of contents/ container to an approved waste disposal plant.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type substance
Chemical Name CAS Number Concentration Hazardous
ammonium chloride EC: 235-186-4 12125-02-9 100% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

After inhalation: fresh air.

Skin contact

Take off immediately all contaminated clothing. Rinse skin with water/ shower.

Eye contact

After eye contact: rinse out with plenty of water. Call in ophthalmologist. Remove contact lenses.

Ingestion

After swallowing: immediately make victim drink water (two glasses at most). Consult a physician.

Immediate Medical Attention

Call in ophthalmologist. Consult a physician.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use extinguishing measures that are appropriate to local circumstances and the surrounding environment.

Unsuitable media

For this substance/mixture no limitations of extinguishing agents are given.

Specific hazards

Not combustible. Fire may cause evolution of: nitrogen oxides, Hydrogen chloride gas. Ambient fire may liberate hazardous vapours.

Instructions

Suppress (knock down) gases/vapors/mists with a water spray jet.

Firefighter Protection

In the event of fire, wear self-contained breathing apparatus.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Avoid inhalation of dusts. Avoid substance contact. Ensure adequate ventilation. Evacuate the danger area, observe emergency procedures, consult an expert.

Environmental

Do not let product enter drains.

Cleanup methods

Take up dry. Clean up affected area.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

For precautions see section 2.2.

Storage

Tightly closed. Dry. Recommended storage temperature see product label.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Hands

This recommendation applies only to the product stated in the safety data sheet, supplied by us and for the designated use. When dissolving in or mixing with other substances and under conditions deviating from those stated in EN 16523-1 please contact the supplier of CE-approved gloves (e.g. KCL GmbH, D-36124 Eichenzell, Internet: www.kcl.de). Full contact Material: Nitrile rubber Minimum layer thickness: 0,11 mm Break through time: 480 min Material tested: KCL 741 Dermatril® L. Splash contact Material: Nitrile rubber Minimum layer thickness: 0,11 mm Break through time: 480 min Material tested: KCL 741 Dermatril® L

Eyes

Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU). Safety glasses

Respiratory

required when dusts are generated. Our recommendations on filtering respiratory protection are based on the following standards: DIN EN 143, DIN 14387 and other accompanying standards relating to the used respiratory protection system. Recommended Filter type: Filter type P2. The entrepreneur has to ensure that maintenance, cleaning and testing of respiratory protective devices are carried out according to the instructions of the producer. These measures have to be properly documented.

Skin/Body

protective clothing

Environmental

Do not let product enter drains.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Crystalline powder
Physical State Data
solid
State Under Standard Conditions
---
Appearance
---
Colour
white
Colour Intensity
---
Form
---
Odor
odorless
Odor Threshold
---
Ph
5 - 5,5 at 25 °C
Melting Point
Melting point: 338 °C - (sublimed)
Boiling Point
520 °C
Flash Point
Not applicable
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
---
Vapor Pressure
1,3 hPa at 160,4 °C; 1,3 hPa at 30 °C
Vapor Density
---
Relative Density
No data available
Bulk Density
ca.600 - 900 kg/m³
Density
1,53 g/cm³ at 25 °C
Flammability
The product is not flammable. - Flammability (solids)
Upper Explosive Limit
---
Lower Explosive Limit
---
Explosive Limits
---
Auto Ignition Temperature
> 400 °C - Relative self-ignition temperature for solids does not ignite
Decomposition Temperature
Not applicable
Solubility
---
Partition Coefficient
not applicable for inorganic substances
Solubility In Water
372 g/l at 20 °C
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
No data available
Kinematic Viscosity
No data available
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

The product is chemically stable under standard ambient conditions (room temperature).

Reactivity

No data available

Hazardous reactions

Violent reactions possible with: alkali hydroxides, acids. Risk of ignition or formation of inflammable gases or vapours with: halogen-halogen compounds, alkalines, alkaline substances. Risk of explosion with: nitrates, chlorates, Heavy metal salts, nitrites, Hydrogen cyanide (hydrocyanic acid), Chlorine, silver salt. Strong oxidizing agents.

Avoid

no information available

Incompatible

Aluminum, Lead, Iron, Copper, copper compounds

Decomposition

In the event of fire: see section 5

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Ammonium chloride for analysis EMSURE® ACS,ISO,Reag. Ph Eur?

The signal word is warning.

What is the physical form of Ammonium chloride for analysis EMSURE® ACS,ISO,Reag. Ph Eur?

Ammonium chloride for analysis EMSURE® ACS,ISO,Reag. Ph Eur is a crystalline powder with white color. It has odorless odor.

What is Ammonium chloride for analysis EMSURE® ACS,ISO,Reag. Ph Eur used for?

Reagent for analysis

What are the hazard statements for Ammonium chloride for analysis EMSURE® ACS,ISO,Reag. Ph Eur?

This substance has 2 hazard statements:

  • H302: Harmful if swallowed.
  • H319: Causes serious eye irritation.

What is the melting point of Ammonium chloride for analysis EMSURE® ACS,ISO,Reag. Ph Eur?

The melting point is Melting point: 338 °C - (sublimed) and the boiling point is 520 °C.