Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Hydrazine sulfate
- Product Code
- 201860000; 201861000; 201865000
- Chemical Name
- Hydrazine sulfate
- Synonyms
- Hydrazinium Sulfate; Hydrazine dihydrogen sulfate salt; Hydrazine hydrogen sulfate; Hydrazine monosulfate
Regulatory Identifiers
- CAS Number
- 10034-93-2 Check regulations →
- EC Number
- 233-110-4 Check regulations →
Identified Uses
Laboratory chemicals.
Uses advised against
No Information available
Manufacturers & Suppliers
Fisher Scientific UK
distributor
Bishop Meadow Road, Loughborough, Leicestershire LE11 5RG, United Kingdom
Thermo Fisher Scientific
distributor
Janssen Pharmaceuticalaan 3a, 2440 Geel, Belgium
Emergency Contacts
Information US
001-800-227-6701
Information Europe
+32 14 57 52 11
Emergency Number US
001-201-796-7100
Emergency Number Europe
+32 14 57 52 99
CHEMTREC
001-800-424-9300
CHEMTREC
001-703-527-3887
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS05
GHS06
GHS08
GHS09
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Hydrazine sulfate EC: 233-110-4 | 10034-93-2 | 100% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove to fresh air. If not breathing, give artificial respiration. Do not use mouth-to-mouth method if victim ingested or inhaled the substance; give artificial respiration with the aid of a pocket mask equipped with a one-way valve or other proper respiratory medical device.
Wash off immediately with plenty of water for at least 15 minutes.
Symptoms: May cause allergic skin reaction. Symptoms of allergic reaction may include rash, itching, swelling, tingling of the hands and feet.
In the case of contact with eyes, rinse immediately with plenty of water and seek medical advice. Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes.
Do NOT induce vomiting. Call a physician or poison control center immediately.
Symptoms: Ingestion causes severe swelling, severe damage to the delicate tissue and danger of perforation.
Immediate Medical Attention
Immediate medical attention is required for all exposure routes.
Medical Treatment
Treat symptomatically.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
CO₂, dry chemical, dry sand, alcohol-resistant foam.
No information available.
The product causes burns of eyes, skin and mucous membranes.
Firefighter Protection
As in any fire, wear self-contained breathing apparatus pressure-demand, MSHA/NIOSH (approved or equivalent) and full protective gear.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Use personal protective equipment as required. Evacuate personnel to safe areas. Ensure adequate ventilation. Keep people away from and upwind of spill/leak. Avoid dust formation.
Do not flush into surface water or sanitary sewer system. Do not allow material to contaminate ground water system. Prevent product from entering drains.
Sweep up and shovel into suitable containers for disposal.
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Wear personal protective equipment/face protection. Do not get in eyes, on skin, or on clothing. Use only under a chemical fume hood. Do not ingest. If swallowed then seek immediate medical assistance. Do not breathe (dust, vapor, mist, gas). Avoid dust formation.
Keep containers tightly closed in a dry, cool and well-ventilated place.
Handle in accordance with good industrial hygiene and safety practice.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Use only under a chemical fume hood. Ensure that eyewash stations and safety showers are close to the workstation location. Wherever possible, engineering control measures such as the isolation or enclosure of the process, the introduction of process or equipment changes to minimise release or contact, and the use of properly designed ventilation systems, should be adopted to control hazardous materials at source
Protective gloves. Glove material: Natural rubber, Nitrile rubber, Neoprene, PVC. Breakthrough time: See manufacturers recommendations. EU standard: EN 374. Glove comments: (minimum requirement). Inspect gloves before use. Please observe the instructions regarding permeability and breakthrough time which are provided by the supplier of the gloves. (Refer to manufacturer/supplier for information). Ensure gloves are suitable for the task: Chemical compatability, Dexterity, Operational conditions, User susceptibility, e.g. sensitisation effects, also take into consideration the specific local conditions under which the product is used, such as the danger of cuts, abrasion. Remove gloves with care avoiding skin contamination.
Goggles (European standard - EN 166)
When workers are facing concentrations above the exposure limit they must use appropriate certified respirators. To protect the wearer, respiratory protective equipment must be the correct fit and be used and maintained properly. Large scale/emergency use: Use a NIOSH/MSHA or European Standard EN 136 approved respirator if exposure limits are exceeded or if irritation or other symptoms are experienced. Recommended Filter type: Particulates filter conforming to EN 143. Small scale/Laboratory use: Use a NIOSH/MSHA or European Standard EN 149:2001 approved respirator if exposure limits are exceeded or if irritation or other symptoms are experienced. Recommended half mask:- Particle filtering: EN149:2001. When RPE is used a face piece Fit Test should be conducted
Long sleeved clothing.
Prevent product from entering drains. Do not allow material to contaminate ground water system. Local authorities should be advised if significant spillages cannot be contained.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under normal conditions.
None known, based on information available
None under normal processing. Hazardous polymerization does not occur.
Incompatible products. Excess heat.
Bases. Reducing Agent. Oxidizing agent.
Nitrogen oxides (NOx). Sulfur oxides. Thermal decomposition can lead to release of irritating gases and vapors.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- UN2923
- Shipping Name
- CORROSIVE SOLID, TOXIC, N.O.S.
- Transport Class
- 8
- Packing Group
- III
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What other names is Hydrazine sulfate known by?
Hydrazine sulfate is also known as: Hydrazinium Sulfate; Hydrazine dihydrogen sulfate salt; Hydrazine hydrogen sulfate; Hydrazine monosulfate
What is the hazard signal word for Hydrazine sulfate?
The signal word is danger.
What is the physical form of Hydrazine sulfate?
Hydrazine sulfate is a solid appearing as white . It has odorless odor.
What is the solubility of Hydrazine sulfate?
No information available
What is Hydrazine sulfate used for?
Laboratory chemicals.
What are the hazard statements for Hydrazine sulfate?
This substance has 5 hazard statements:
- H301 + H311 + H331: Toxic if swallowed, in contact with skin or if inhaled
- H314: Causes severe skin burns and eye damage
- H317: May cause an allergic skin reaction
- H350: May cause cancer
- H410: Very toxic to aquatic life with long lasting effects
What is the melting point of Hydrazine sulfate?