Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Acetic acid glacial
- Product Code
- A/0406/PB08, A/0406/PB15
- Chemical Name
- Acetic acid glacial
- Synonyms
- Ethanoic acid; Glacial acetic acid; Methanecarboxylic acid
Regulatory Identifiers
- CAS Number
- 64-19-7 Check regulations →
- EC Number
- 200-580-7 Check regulations →
- REACH No.
- 01-2119475328-30
Identified Uses
Laboratory chemicals. Sector of use: SU3 - Industrial uses: Uses of substances as such or in preparations at industrial sites. Product category: PC21 - Laboratory chemicals. Process categories: PROC15 - Use as a laboratory reagent. Environmental release category: ERC6a - Industrial use resulting in manufacture of another substance (use of intermediates)
Uses advised against
No Information available
Manufacturers & Suppliers
Fisher Scientific UK
national supplier
Bishop Meadow Road, Loughborough, Leicestershire LE11 5RG, United Kingdom
Thermo Fisher Scientific
national supplier
Janssen Pharmaceuticalaan 3a, 2440 Geel, Belgium
Emergency Contacts
Chemtrec US
(800) 424-9300
Chemtrec EU
001-703-527-3887
Emergency Contact
01509 231166
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS02
GHS05
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Acetic acid EC: 200-580-7 | 64-19-7 | 95% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
If not breathing, give artificial respiration. Remove from exposure, lie down. Do not use mouth-to-mouth method if victim ingested or inhaled the substance; give artificial respiration with the aid of a pocket mask equipped with a one-way valve or other proper respiratory medical device. Call a physician immediately.
Wash off immediately with plenty of water for at least 15 minutes. Remove and wash contaminated clothing and gloves, including the inside, before re-use. Call a physician immediately.
Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. Immediate medical attention is required.
Do NOT induce vomiting. Clean mouth with water. Never give anything by mouth to an unconscious person. Call a physician immediately.
Symptoms: Ingestion causes severe swelling, severe damage to the delicate tissue and danger of perforation
Immediate Medical Attention
Immediate medical attention is required.
Medical Treatment
Treat symptomatically.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
CO₂, dry chemical, dry sand, alcohol-resistant foam.
No information available.
Thermal decomposition can lead to release of irritating gases and vapors. The product causes burns of eyes, skin and mucous membranes.
Firefighter Protection
As in any fire, wear self-contained breathing apparatus pressure-demand, MSHA/NIOSH (approved or equivalent) and full protective gear.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Use personal protective equipment as required. Ensure adequate ventilation. Evacuate personnel to safe areas. Keep people away from and upwind of spill/leak.
Should not be released into the environment.
Soak up with inert absorbent material.
Materials: inert absorbent material
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Do not get in eyes, on skin, or on clothing. Wear personal protective equipment/face protection. Use only under a chemical fume hood. Do not breathe mist/vapors/spray. Do not ingest. If swallowed then seek immediate medical assistance.
Keep containers tightly closed in a dry, cool and well-ventilated place.
Handle in accordance with good industrial hygiene and safety practice.
Keep away from heat, sparks and flame.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Use only under a chemical fume hood. Use explosion-proof electrical/ventilating/lighting equipment. Ensure that eyewash stations and safety showers are close to the workstation location. Ensure adequate ventilation, especially in confined areas. Wherever possible, engineering control measures such as the isolation or enclosure of the process, the introduction of process or equipment changes to minimise release or contact, and the use of properly designed ventilation systems, should be adopted to control hazardous materials at source
Protective gloves. Glove material: Butyl rubber, Breakthrough time: >480 minutes, Glove thickness: 0.7 mm, EU standard: EN 374 (minimum requirement)
Tight sealing safety goggles or Face protection shield Goggles (European standard - EN 166)
When workers are facing concentrations above the exposure limit they must use appropriate certified respirators. Large scale/emergency use: Use a NIOSH/MSHA or European Standard EN 136 approved respirator if exposure limits are exceeded or if irritation or other symptoms are experienced. Recommended Filter type: Particulates filter conforming to EN 143 Acid gases filter Type E Yellow conforming to EN14387. Small scale/Laboratory use: Use a NIOSH/MSHA or European Standard EN 149:2001 approved respirator if exposure limits are exceeded or if irritation or other symptoms are experienced. Recommended half mask:- Valve filtering: EN405; or; Half mask: EN140; plus filter, EN 141
Long sleeved clothing.
Prevent product from entering drains.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under normal conditions.
None known, based on information available
Hazardous polymerization does not occur. None under normal processing.
Incompatible products. Excess heat. Keep away from open flames, hot surfaces and sources of ignition.
Strong oxidizing agents. Strong bases. Metals.
Carbon monoxide (CO). Carbon dioxide $(\mathrm{CO}_{2})$ . Thermal decomposition can lead to release of irritating gases and vapors.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- UN2789
- Shipping Name
- ACETIC ACID, GLACIAL
- Transport Class
- 8
- Packing Group
- II
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What other names is Acetic acid glacial known by?
Acetic acid glacial is also known as: Ethanoic acid; Glacial acetic acid; Methanecarboxylic acid
What is the hazard signal word for Acetic acid glacial?
The signal word is danger.
What is the physical form of Acetic acid glacial?
Acetic acid glacial is a liquid appearing as colorless . It has vinegar-like odor.
What is Acetic acid glacial used for?
Laboratory chemicals. Sector of use: SU3 - Industrial uses: Uses of substances as such or in preparations at industrial sites. Product category: PC21 - Laboratory chemicals. Process categories: PROC15 - Use as a laboratory reagent. Environmental release category: ERC6a - Industrial use resulting in manufacture of another substance (use of intermediates)
What are the hazard statements for Acetic acid glacial?
This substance has 2 hazard statements:
- H226: Flammable liquid and vapor
- H314: Causes severe skin burns and eye damage
What is the melting point of Acetic acid glacial?
The melting point is 16 - 16.5 °C / 60.8 - 61.7 °F and the boiling point is 117 - 118 °C / 242.6 - 244.4 °F.