Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- GRF PE CLNR HEAVY DUTY BO 1L*12 L105
Regulatory Identifiers
- CAS Number
- N/A
- EC Number
- 927-510-4 Check regulations →
- REACH No.
- 01-2119475515-33
Identified Uses
Cleaning agent/ Cleaner
Uses advised against
No further relevant information available.
Manufacturers & Suppliers
Bison International
manufacturer
Dr.A.F.Philipsstraat 9, NL-4462 EW Goes, PO Box 160, NL-4460 AD Goes
+31 88 3235700
Emergency Contacts
National Poisons Information Centre
+353 (1) 809 2166
8.00 a.m. to 10.00 p.m. 7 days a week
Healthcare Professionals
+353 (1) 809 2566
24 hour service
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS02
GHS07
GHS08
GHS09
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Hydrocarbons, C7, n-alkanes, isoalkanes, cyclics EC: 927-510-4 | --- | 50 - 100% | Yes |
| cyclohexane EC: 203-806-2 | 110-82-7 | 1 - 2.5% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
In case of unconsciousness place patient stably in side position for transportation.
Immediately wash with water and soap and rinse thoroughly.
Rinse opened eye for several minutes under running water.
If symptoms persist consult doctor.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Water haze, Alcohol resistant foam, Fire-extinguishing powder, Carbon dioxide
Water with full jet
No further relevant information available.
Cool endangered receptacles with water spray.
Firefighter Protection
Protective equipment: No special measures required.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Wear protective equipment. Keep unprotected persons away.
Do not allow to enter sewers/ surface or ground water.
Absorb with liquid-binding material (sand, diatomite, acid binders, universal binders, sawdust).
Materials: liquid-binding material (sand, diatomite, acid binders, universal binders, sawdust)
Related Products
Similar products with comparable safety profiles
GRF UNI-100 XT BO 1L*8 ENDE
---
GRF UNI-100 XT BO 1L*8 ENDE
---
GRF LUBRICANT JR 700G*12 L49
CAS: 8009-03-8
GRF HT-120 BO 500ML*12 L222
---
GRF CLEANER PVC TI 1L*6 L58
CAS: 78-93-3
GRF CLEANER PVC TI 1L*6 L58
CAS: 78-93-3
GRF CLEANER PVC TI 1L*6 L58
CAS: 78-93-3
GRF CLEANER PVC TI 1L*6 L58
CAS: 78-93-3
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Ensure good interior ventilation, especially at floor level. (Fumes are heavier than air). Ensure good ventilation/exhaustion at the workplace. Prevent formation of aerosols.
Store in a cool location. Keep container tightly sealed. Store in cool, dry conditions in well sealed receptacles.
Keep ignition sources away - Do not smoke.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
No further data; see item 7.
Solvent resistant gloves. Protective gloves. The glove material has to be impermeable and resistant to the product/ the substance/ the preparation. Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation. Material of gloves: Recommended thickness of the material: > 0,12 mm. Nitrile rubber, NBR. Penetration time of glove material: For the mixture of chemicals mentioned below the penetration time has to be at least 10 minutes (Permeation according to EN 374 Part 3: Level 1).
Tightly sealed goggles. Goggles recommended during refilling.
Use suitable respiratory protective device in case of insufficient ventilation. Recommended filter device for short term use: Filter A.
Use protective suit. Solvent resistant protective clothing.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
No decomposition if used according to specifications.
No further relevant information available.
No dangerous reactions known.
No decomposition if used according to specifications.
No further relevant information available.
Danger of forming toxic pyrolysis products.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 1206
- Shipping Name
- HEPTANES
- Transport Class
- 3
- Packing Group
- II
Warning: Flammable liquids.
Warning: Flammable liquids.
Warning: Flammable liquids.
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for GRF PE CLNR HEAVY DUTY BO 1L*12 L105?
The signal word is danger.
What is the physical form of GRF PE CLNR HEAVY DUTY BO 1L*12 L105?
GRF PE CLNR HEAVY DUTY BO 1L*12 L105 is a fluid appearing as transparent with transparent color. It has characteristic odor.
What is GRF PE CLNR HEAVY DUTY BO 1L*12 L105 used for?
Cleaning agent/ Cleaner
What are the hazard statements for GRF PE CLNR HEAVY DUTY BO 1L*12 L105?
This substance has 5 hazard statements:
- H225: Highly flammable liquid and vapour.
- H304: May be fatal if swallowed and enters airways.
- H315: Causes skin irritation.
- H336: May cause drowsiness or dizziness.
- H411: Toxic to aquatic life with long lasting effects.
What is the melting point of GRF PE CLNR HEAVY DUTY BO 1L*12 L105?
The melting point is -50 °C and the boiling point is 162 °C.