NextSDS Logo
Safety Data Sheet EN

Perfluoro-3-methoxypropanoic acid

CAS 377-73-1*

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Perfluoro-3-methoxypropanoic acid
Product Code
PC10622
Chemical Name
2,2,3,3-tetrafluoro-3-(trifluoromethoxy)propanoic acid

Regulatory Identifiers

CAS Number
377-73-1* Check regulations →

Identified Uses

Not Available

Uses advised against

No specific uses advised against are identified.

Manufacturers & Suppliers

A

Apollo Scientific

manufacturer

Apollo Scientific logo

Apollo Scientific

manufacturer

Whitefield Road, Bredbury SK62QR United Kingdom

01614060505

http://www.apolloscientific.co.uk/

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Skin Corr. Cat. 1B H314
Met. Corr. Cat. 1 H290
Eye Dam. Cat. 1 H318
STOT SE Cat. 3 H335

GHS Pictograms

GHS05 - Corrosive

GHS05

GHS07 - Health hazard

GHS07

Hazard Statements

H290 May be corrosive to metals.
H314 Causes severe skin burns and eye damage.
H335 May cause respiratory irritation.

Precautionary Statements

P234 Keep only in original packaging.
P260 Do not breathe mist/vapours/spray.
P264 Wash all exposed external body areas thoroughly after handling.
P271 Use only outdoors or in a well-ventilated area.
P280 Wear protective gloves, protective clothing, eye protection and face protection.
P301 + P330 + P331 IF SWALLOWED: Rinse mouth. Do NOT induce vomiting.
P303 + P361 + P353 IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water [or shower].
P304 + P340 IF INHALED: Remove person to fresh air and keep comfortable for breathing.
P305 + P351 + P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
P310 Immediately call a POISON CENTER/doctor/physician/first aider.
P363 Wash contaminated clothing before reuse.
P390 Absorb spillage to prevent material damage.
P403 + P233 Store in a well-ventilated place. Keep container tightly closed.
P405 Store locked up.
P501 Dispose of contents/container to authorised hazardous or special waste collection point in accordance with any local regulation.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type substance
Chemical Name CAS Number Concentration Hazardous
Perfluoro-3-methoxypropanoic acid --- 100% No

available; [e] Substance identified as having endocrine disrupting properties

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

If fumes or combustion products are inhaled remove from contaminated area. Lay patient down. Keep warm and rested. Prostheses such as false teeth, which may block airway, should be removed, where possible, prior to initiating first aid procedures. Apply artificial respiration if not breathing, preferably with a demand valve resuscitator, bag-valve mask device, or pocket mask as trained. Perform CPR if necessary. Transport to hospital, or doctor, without delay.

Symptoms: Inhalation of vapours or aerosols (mists, fumes) may cause lung oedema. Corrosive substances may cause lung damage (e.g. lung oedema, fluid in the lungs).

Skin contact

Immediately flush body and clothes with large amounts of water, using safety shower if available. Quickly remove all contaminated clothing, including footwear. Wash skin and hair with running water. Continue flushing with water until advised to stop by the Poisons Information Centre. Transport to hospital, or doctor.

Eye contact

Immediately hold eyelids apart and flush the eye continuously with running water. Ensure complete irrigation of the eye by keeping eyelids apart and away from eye and moving the eyelids by occasionally lifting the upper and lower lids. Continue flushing until advised to stop by the Poisons Information Centre or a doctor, or for at least 15 minutes. Transport to hospital or doctor without delay. Removal of contact lenses after an eye injury should only be undertaken by skilled personnel.

Ingestion

For advice, contact a Poisons Information Centre or a doctor at once. Urgent hospital treatment is likely to be needed. If swallowed do NOT induce vomiting. If vomiting occurs, lean patient forward or place on left side (head-down position, if possible) to maintain open airway and prevent aspiration. Observe the patient carefully. Never give liquid to a person showing signs of being sleepy or with reduced awareness; i.e. becoming unconscious. Give water to rinse out mouth, then provide liquid slowly and as much as casualty can comfortably drink. Transport to hospital or doctor without delay.

Immediate Medical Attention

Transport to hospital or doctor without delay.

Medical Treatment

Before any such manifestation, the administration of a spray containing a dexamethasone derivative or beclomethasone derivative may be considered. This must definitely be left to a doctor or person authorised by him/her.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Foam, Dry chemical powder, BCF (where regulations permit), Carbon dioxide, Water spray or fog - Large fires only.

Specific hazards

Avoid contamination with oxidising agents i.e. nitrates, oxidising acids, chlorine bleaches, pool chlorine etc. as ignition may result

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

See section 8

Small spill

Drains for storage or use areas should have retention basins for pH adjustments and dilution of spills before discharge or disposal of material. Check regularly for spills and leaks. Clean up all spills immediately. Avoid breathing vapours and contact with skin and eyes. Control personal contact with the substance, by using protective equipment. Contain and absorb spill with sand, earth, inert material or vermiculite. Wipe up. Place in a suitable, labelled container for waste disposal.

Environmental

See section 12

Cleanup methods

Wipe up.

Materials: sand, earth, inert material or vermiculite

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Avoid all personal contact, including inhalation. Wear protective clothing when risk of exposure occurs. Use in a well-ventilated area. Avoid contact with moisture. Avoid contact with incompatible materials. When handling, DO NOT eat, drink or smoke. Keep containers securely sealed when not in use. Avoid physical damage to containers. Always wash hands with soap and water after handling. Work clothes should be laundered separately. Launder contaminated clothing before re-use. Use good occupational work practice. Observe manufacturer's storage and handling recommendations contained within this SDS. Atmosphere should be regularly checked against established exposure standards to ensure safe working conditions are maintained.

Storage

Store in original containers. Keep containers securely sealed. Store in a cool, dry, well-ventilated area. Store away from incompatible materials and foodstuff containers. Protect containers against physical damage and check regularly for leaks. Observe manufacturer's storage and handling recommendations contained within this SDS.

Hygiene

When handling, DO NOT eat, drink or smoke. Always wash hands with soap and water after handling. Work clothes should be laundered separately. Launder contaminated clothing before re-use.

Fire prevention

See section 5

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Engineering controls are used to remove a hazard or place a barrier between the worker and the hazard. Local exhaust ventilation usually required. Provide adequate ventilation in warehouse or closed storage area.

Hands

Wear chemical protective gloves, e.g. PVC.

Eyes

Chemical goggles. [AS/NZS 1337.1, EN166 or national equivalent] Full face shield may be required for supplementary but never for primary protection of eyes.

Respiratory

Type AB Filter of sufficient capacity. (AS/NZS 1716 & 1715, EN 143:2000 & 149:2001, ANSI Z88 or national equivalent). If risk of overexposure exists, wear approved respirator. Correct fit is essential to obtain adequate protection. Supplied-air type respirator may be required in special circumstances. An approved self contained breathing apparatus (SCBA) may be required in some situations.

Skin/Body

Wear safety footwear or safety gumboots, e.g. Rubber When handling corrosive liquids, wear trousers or overalls outside of boots, to avoid spills entering boots. Overalls. PVC Apron. PVC protective suit may be required if exposure severe.

Environmental

See section 12

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
Not Available
Colour
---
Colour Intensity
---
Form
---
Odor
Not Available
Odor Threshold
Not Available
Ph
Not Available
Melting Point
Not Available
Boiling Point
126/740mm
Flash Point
Not Available
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
Not Available
Vapor Pressure
Not Available
Vapor Density
Not Available
Relative Density
Not Available
Bulk Density
---
Density
---
Flammability
Not Available
Upper Explosive Limit
Not Available
Lower Explosive Limit
Not Available
Explosive Limits
---
Auto Ignition Temperature
Not Available
Decomposition Temperature
Not Available
Solubility
---
Partition Coefficient
Not Available
Solubility In Water
Not Available
Solubility In Fat
---
Molecular Weight
Not Available
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
Not Available
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Contact with alkaline material liberates heat

Reactivity

See section 7.2

Hazardous reactions

See section 7.2

Avoid

See section 7.2

Incompatible

See section 7.2

Decomposition

See section 5.3

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
3265
Shipping Name
CORROSIVE LIQUID, ACIDIC, ORGANIC, N.O.S.
Transport Class
8
Packing Group
III
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Perfluoro-3-methoxypropanoic acid?

The signal word is danger.

What is the physical form of Perfluoro-3-methoxypropanoic acid?

Perfluoro-3-methoxypropanoic acid is a liquid appearing as not available . It has not available odor.

What is Perfluoro-3-methoxypropanoic acid used for?

Not Available

What are the hazard statements for Perfluoro-3-methoxypropanoic acid?

This substance has 3 hazard statements:

  • H290: May be corrosive to metals.
  • H314: Causes severe skin burns and eye damage.
  • H335: May cause respiratory irritation.

What is the melting point of Perfluoro-3-methoxypropanoic acid?

The melting point is Not Available and the boiling point is 126/740mm.