Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- 1,1,3,3-Tetramethoxypropane
- Product Code
- M0544
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
For laboratory research purposes.
Uses advised against
Not for drug or household use.
Manufacturers & Suppliers
TOKYO CHEMICAL INDUSTRY CO., LTD.
manufacturer
6-15-9 Toshima, Kita-ku, Tokyo 114-0003, Japan
+81-3-5640-8878
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS02
Hazard Statements
Precautionary Statements
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| 1,1,3,3-Tetramethoxypropane | 102-52-3 | 98 - 100% | No |
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove person to fresh air and keep comfortable for breathing.
Take off all contaminated clothing immediately. If on skin, rinse well with water.
Rinse with plenty of water. If easy to do, remove contact lens, if worn.
Rinse mouth.
Immediate Medical Attention
Get medical advice/ attention if you feel unwell (inhalation). If skin irritation or rash occurs: Get medical advice/ attention. If eye irritation persists: Get medical advice/ attention. Get medical advice/ attention (ingestion).
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Dry powder, Foam, Water spray, Carbon dioxide (CO2)
Take care as it may decompose upon combustion or in high temperatures to generate poisonous fume.
Use extinguishing measures that are appropriate to local circumstances and the surrounding environment. Immediately evacuate personnel to safe areas. Remove undamaged containers from fire area if it is safe to do so.
Firefighter Protection
Use personal protective equipment.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Wear suitable protective equipment. Keep people away from and upwind of spill/leak. Ensure adequate ventilation. Entry to non-involved personnel should be controlled around the leakage area by roping off, etc.
Prevent product from entering drains.
Collect as much of the spill as possible with a suitable absorbent material.
Materials: suitable absorbent material
Related Products
Similar products with comparable safety profiles
2,2-Dimethoxypropane
CAS: 77-76-9
2,2-Dimethoxypropane
CAS: 77-76-9
1,1,2,2-Tetrabromoethane
CAS: 79-27-6
1,2,3-Trichloropropane
CAS: 96-18-4
1,2,3-trichloropropane
CAS: 96-18-4
1,3-Dichloropropane
CAS: 142-28-9
1,1,3,3-tetrachloroprop-1-ene
CAS: 18611-43-3
1,1-Dichloropropane
CAS: 78-99-9
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Avoid contact with skin, eyes and clothing. Wear personal protective equipment. Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking. Wash hands and face thoroughly after handling.
Keep container tightly closed. Store in a cool and shaded area. Keep in a well-ventilated place. Use explosion-proof equipment. Protect from moisture. Keep under inert gas.
Wash hands and face thoroughly after handling.
Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking. Take precautionary measures against static discharge.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Install a closed system or local exhaust. Also install safety shower and eye bath.
Protective gloves
Safety glasses, Face-shield
Gas mask
Protective suit
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under normal conditions.
No data available
None under normal processing.
Electrical spark, Open flame, Electrostatic discharge, Exposure to moisture.
Oxidizing agents
Carbon monoxide, Carbon dioxide (CO2)
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 3271
- Shipping Name
- Ethers, n.o.s.
- Transport Class
- 3
- Packing Group
- III
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for 1,1,3,3-Tetramethoxypropane?
The signal word is warning.
What is the physical form of 1,1,3,3-Tetramethoxypropane?
1,1,3,3-Tetramethoxypropane is a liquid with colorless - yellow color. It has no data available odor.
What is 1,1,3,3-Tetramethoxypropane used for?
For laboratory research purposes.
What are the hazard statements for 1,1,3,3-Tetramethoxypropane?
This substance has 1 hazard statement:
- H226: Flammable liquid and vapor.
What is the melting point of 1,1,3,3-Tetramethoxypropane?
The melting point is No data available and the boiling point is 183 °C.