Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- BD Vacutainer® K2EDTA Tubes
- Product Code
- 362089, 364661, 364664, 367838, 368274, 368499, 365300, 365312, 365329, 365330, 365331, 365900, 366164, 366643, 367386, 367525, 367839, 367864, 367873, 367918, 367924, 367941, 367950, 367978, 368267, 368834, 368841, 368843, 368856, 368860
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Blood collection (In-Vitro Diagnostic) device for collecting blood samples for analysis
Uses advised against
None known.
Manufacturers & Suppliers
Becton Dickinson UK Ltd.
manufacturer
The Danby Building, Edmund Halley Road, Oxford Science Park, OX4 4DQ, Oxford, United Kingdom
UK: +44 (0) 1752 701281; USA: 800-631-0174
Emergency Contacts
Chemtrec EU
703-527-3887
Chemtrec US
1-800-424-9300
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS07
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Dipotassium dihydrogen ethylenediaminetetraacetate | 25102-12-9 | 100% | No |
BD Vacutainer® K2EDTA Tubes 927965 Version #: 01 Revision date: - Issue date: 15-September-2015 SDS US <!-- PAGE 2 -->
Notes
All concentrations are in percent by weight unless ingredient is a gas. Gas concentrations are in percent by volume.
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove victim to fresh air and keep at rest in a position comfortable for breathing. Call a poison center or doctor/physician if you feel unwell.
Wash skin thoroughly with soap and water. Get medical attention if irritation develops and persists.
Rinse with water. Do not rub eye. Make sure to remove any contact lenses from the eyes before rinsing. Get medical attention if irritation develops and persists.
Rinse mouth thoroughly if dust is ingested. Get medical attention if any discomfort occurs.
Immediate Medical Attention
Treat symptomatically.
Medical Treatment
Treat symptomatically.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Dry chemical. Foam.
Carbon dioxide (CO2).
Explosion hazard: Avoid generating dust; fine dust dispersed in air in sufficient concentrations and in the presence of an ignition source is a potential dust explosion hazard. During fire, gases hazardous to health may be formed.
Use standard firefighting procedures and consider the hazards of other involved materials. Containers close to fire should be removed or cooled with water.
Firefighter Protection
Selection of respiratory protection for firefighting: follow the general fire precautions indicated in the workplace. Self-contained breathing apparatus and full protective clothing must be worn in case of fire.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Avoid discharge into drains, water courses or onto the ground unless authorized by permit.
Collect dust using a vacuum cleaner equipped with HEPA filter.
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
No specific precautions due to the small quantities handled. However: Explosion-proof general and local exhaust ventilation. Minimize dust generation and accumulation. Provide adequate ventilation. Do not breathe dust. Do not get in eyes, on skin, or on clothing. Do not taste or swallow. When using, do not eat, drink or smoke. Wear appropriate personal protective equipment. Wash hands thoroughly after handling. Keep the workplace clean. Observe good industrial hygiene practices.
Store in original tightly closed container. Store in a cool, dry place.
When using, do not eat, drink or smoke. Wash hands thoroughly after handling. Keep the workplace clean. Observe good industrial hygiene practices.
Keep away from heat, sparks and open flame.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
No specific recommendation made, but protection against nuisance dust must be used when the general level exceeds 10 mg/m3.
Wear appropriate chemical resistant gloves. Suitable gloves can be recommended by the glove supplier.
It is a good industrial hygiene practice to minimize eye contact. Risk of contact: Wear dust goggles.
No protection is ordinarily required under normal conditions of use and with adequate ventilation. If engineering measures are not sufficient to maintain concentrations of dust particulates below the OEL, suitable respiratory protection must be worn. In the United States of America, if respirators are used, a program should be instituted to assure compliance with OSHA 29 CFR 1910.134.
No skin protection is ordinarily required under normal conditions of use. In accordance with good industrial hygiene practices, precautions should be taken to avoid skin contact.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Material is stable under normal conditions.
The product is stable and non-reactive under normal conditions of use, storage and transport.
No dangerous reaction known under conditions of normal use.
Avoid dust formation.
None known.
Thermal decomposition: > 150°C.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for BD Vacutainer® K2EDTA Tubes?
The signal word is warning.
What is the physical form of BD Vacutainer® K2EDTA Tubes?
BD Vacutainer® K2EDTA Tubes is a liquid appearing as white with white color. It has odorless odor.
What is BD Vacutainer® K2EDTA Tubes used for?
Blood collection (In-Vitro Diagnostic) device for collecting blood samples for analysis
What are the hazard statements for BD Vacutainer® K2EDTA Tubes?
This substance has 1 hazard statement:
- H332: Harmful if inhaled.
What is the melting point of BD Vacutainer® K2EDTA Tubes?
The melting point is 485.6 °F (252 °C) and the boiling point is Decomposes.