Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- EDTA (0.5 M, pH 7.4)
- Product Code
- BM-711
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Research Use or Further Manufacturing
Manufacturers & Suppliers
Boston BioProducts, Inc.
manufacturer
425 Fortune Blvd. Milford, MA 01757
Emergency Contacts
Emergency Contact
1-800-535-5053
Emergency Contact
1-888-881-8691
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS07
Hazard Statements
Precautionary Statements
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
Mixture of 500 mM EDTA Tetrasodium Tetrahydrate Salt and EDTA Disodium Salt Dihydrate, pH 7.40 ± 0.20.
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| EDTA Tetrasodium Tetrahydrate Salt / EDTA Disodium Salt Dihydrate | --- | 20.68% | No |
| Water | 7732-18-5 | --- | No |
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove to fresh air and monitor breathing. If breathing becomes difficult, give oxygen. If breathing stops, give artificial respiration. Consult a doctor.
Immediately wash skin with copious amounts of soap and water for at least 15 minutes. Remove contaminated clothing and shoes and wash before reuse. Consult a doctor.
Flush with copious amounts of water for at least 15 minutes. Consult a doctor.
Rinse mouth with water. Do not induce vomiting unless directed to do so by medical personnel. Never give anything by mouth to an unconscious person. Consult a doctor.
Immediate Medical Attention
Immediate medical attention is required.
Medical Treatment
Show this safety data sheet to the doctor in attendance.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use water spray, alcohol-resistant foam, dry chemical or carbon dioxide
Carbon oxides, nitrogen oxides (NOx).
Firefighter Protection
Wear suitable protective clothing to prevent contact with skin and eyes and self-contained breathing apparatus.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Do not take action without suitable protective clothing - see section 8 of SDS. Evacuate personnel to safe areas.
Do not let product enter drains.
Using non-spark tools, sweep up material and place in an appropriate container.
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Use in a chemical fume hood, with air supplied by an independent system. Avoid inhalation, contact with eyes, skin and clothing. Avoid the formation of dust and aerosols. Use in a well-ventilated area. Keep away from sources of ignition. Avoid prolonged or repeated exposure.
Store in cool, well-ventilated area. Keep away from direct sunlight. Keep container tightly sealed until ready for use. Keep in a dry place.
Keep away from sources of ignition.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Use in a fume hood where applicable. Ensure all engineering measures described under section 7 of SDS are in place.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under recommended storage conditions.
No Data Available.
Strong oxidizing agent
No Data Available.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
Ecotoxicity
Persistence and degradability
Bioaccumulative potential
Mobility in soil
Results of PBT and vPvB assessment
Other adverse effects
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
managed in an appropriate and approved waste disposal facility
Whatever cannot be saved for recovery or recycling should be managed in an appropriate and approved waste disposal facility. Dispose of container and unused contents in accordance with federal, state and local requirements.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for EDTA (0.5 M, pH 7.4)?
The signal word is warning.
What is the physical form of EDTA (0.5 M, pH 7.4)?
EDTA (0.5 M, pH 7.4) is a liquid appearing as clear colorless liquid .
What is EDTA (0.5 M, pH 7.4) used for?
Research Use or Further Manufacturing
What are the hazard statements for EDTA (0.5 M, pH 7.4)?
This substance has 1 hazard statement:
- H319: Cause Serious Eye irritation