Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- MACS ART Annexin V Reagent
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
The MACS ART Annexin V Reagent is a medical device according to MDD 93/42/EEC and is used in combination with the other components of the MACS ART Annexin V System: the MACS ART Binding Buffer, the MACS ART MS Column, and the MACS ART Separation Unit. The MACS ART Annexin V System is intended for the in vitro depletion of apoptotic human spermatozoa by depleting phosphatidylserine-positive cells, from fresh, or cryopreserved, or otherwise manipulated semen samples. The spermatozoa prepared by using the MACS ART Annexin V System may then be used for further operations in Assisted Reproductive Technology (ART).
Manufacturers & Suppliers
Miltenyi Biotec GmbH
manufacturer
Friedrich-Ebert-Str.68, D-51429 Bergisch Gladbach
02204 8306-0
http://www.miltenyibiotec.com
Emergency Contacts
Giftzentrum Mainz
+49 6131 19240
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
The data for this section has not been processed yet.
First Aid Measures
Emergency procedures for chemical exposure incidents
In case of inhaling spray mist, consult a physician.
Water and soap. In case of skin irritation, seek medical treatment. Change contaminated clothing.
Rinse immediately carefully and thoroughly with eye-bath or water. Seek medical advice immediately.
Rinse mouth thoroughly with water. Get medical attention if any discomfort continues.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Not combustible. Co-ordinate fire-fighting measures to the fire surroundings.
No data available.
Firefighter Protection
Protective clothing.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
No data available.
Take up mechanically, placing in appropriate containers for disposal. Wash with plenty of water.
Materials: appropriate containers
Related Products
Similar products with comparable safety profiles
MACS ART Annexin V Reagent
---
MACS ART Binding Buffer
---
Acid Red 26
---
ASSAY, HEMATOXYLIN COUNTERSTAIN, 1504118
---
HEXAMETHYLENETETRAMINE, REAGENT, ACS
---
AEC-Plus Substrate-Chromogen
---
PathoDX EXTRACTION REAGENT 1 (7ml) ®
---
Ethylenediaminetetraacetic acid, ACS
CAS: 60-00-4
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Avoid the formation of aerosol.
Avoid UV-radiation/sunlight, high temperatures and freezing.
No special precautionary measures are necessary.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Tested protective gloves are to be worn: Single-use gloves. German Industry Norms (DIN) / European Norms (EN): DIN EN 374. Suitable material: NR (natural rubber, natural latex). Recommended protective gloves brand: Supreno, Manufacturer. Microfex Cooperation or comparable articles from other companies.
Personal protection equipment
Respiratory protection necessary at: aerosol or mist generation.
Personal protection equipment
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
The product is stable at recommended storage conditions.
No data available.
No data available.
Avoid high temperatures. Do not freeze.
No data available.
No data available.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for MACS ART Annexin V Reagent?
The signal word is no signal word.
What is the physical form of MACS ART Annexin V Reagent?
MACS ART Annexin V Reagent is a liquid with amber to brown color. It has odourless odor.
What is MACS ART Annexin V Reagent used for?
The MACS ART Annexin V Reagent is a medical device according to MDD 93/42/EEC and is used in combination with the other components of the MACS ART Annexin V System: the MACS ART Binding Buffer, the MACS ART MS Column, and the MACS ART Separation Unit. The MACS ART Annexin V System is intended for the in vitro depletion of apoptotic human spermatozoa by depleting phosphatidylserine-positive cells, from fresh, or cryopreserved, or otherwise manipulated semen samples. The spermatozoa prepared by using the MACS ART Annexin V System may then be used for further operations in Assisted Reproductive Technology (ART).
What is the melting point of MACS ART Annexin V Reagent?
The melting point is No data available. and the boiling point is No data available..