Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- ECOBRITE POWER COLOR
- Product Code
- 112286E
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Laundry detergent
Uses advised against
Reserved for industrial and professional use.
Manufacturers & Suppliers
ECOLAB
manufacturer
Ecolab Temizleme Sistemleri Ltd. Şti
national supplier
Esentepe Mahallesi, Cevizli - Esentepe E-5 Yanyol Caddesi, Vizyon Bulvar No: 13, Kat 1 No: 65 Turkey TR 34870 KARTAL / İSTANBUL
+90 (216) 458 69 00
Ecolab Gulf FZE
national supplier
P.O. Box 17063, Jebel Ali Free Zone Area, Near Container Terminal 3 - North Zone, Dubai UAE
00971 4 8014444
Nalco Egypt Trading
national supplier
5th Settlement, South 90th St., The Address Building No 67th – 1st floor, New Cairo, Cairo, Egypt 11835
0020 2 25 37 1195
Ecolab Maroc S.A.R.L.
national supplier
Batiment, Lot. Mounir 1, Parc Industriel, Attawfik, Route 1029 Sidi Maarouf, Casablanca, Morocco
00212 22 58 25 30 - 35
Ecolab Food Safety & Hygiene Solutions Pvt. Ltd
national supplier
WeWork, 247 Park Bus Stop, 13th floor, 247 Park, Hindustan C, LBS Road, Gandhi Nagar, Vikhroli West, Mumbai, Maharashtra. 400 079, India
+91 22 48808555, +91 22 48808535
Emergency Contacts
Trans-European
+32-(0)3-575-5555
Ulusal Zehir Danışma Merkezi (UZEM)
114
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS05
GHS07
GHS09
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Alcohols, C13-15, branched and linear, ethoxylated | 157627-86-6 | 30 - 50% | Yes |
| Alcohols, C13-15, branched and linear, ethoxylated | 157627-86-6 | 20 - 25% | Yes |
| Isopropyl Alcohol EC: 200-661-7 | 67-63-0 | 1 - 2.5% | Yes |
| Dipropylene glycol methyl ether EC: 252-104-2 | 34590-94-8 | 10 - 20% | No |
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove to fresh air. Treat symptomatically. Get medical attention if symptoms occur.
Rinse with plenty of water.
Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. Remove contact lenses, if present and easy to do. Continue rinsing. Get medical attention immediately.
Rinse mouth. Get medical attention if symptoms occur.
Immediate Medical Attention
Get medical attention immediately.
Medical Treatment
Treat symptomatically.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use extinguishing measures that are appropriate to local circumstances and the surrounding environment.
High volume water jet
Fire Hazard. Keep away from heat and sources of ignition. Flash back possible over considerable distance.
In the event of fire and/or explosion do not breathe fumes.
Firefighter Protection
Use personal protective equipment.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Ensure adequate ventilation. Remove all sources of ignition. Keep people away from and upwind of spill/leak. Avoid inhalation, ingestion and contact with skin and eyes. Ensure clean-up is conducted by trained personnel only.
dike spilled material or otherwise contain material to ensure runoff does not reach a waterway.
Do not allow contact with soil, surface or ground water.
collect with non-combustible absorbent material and place in container for disposal according to local / national regulations (see section 13). Flush away traces with water.
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Do not ingest. Do not get in eyes, on skin, or on clothing. Use only with adequate ventilation. Keep away from fire, sparks and heated surfaces. Take necessary action to avoid static electricity discharge (which might cause ignition of organic vapours). Wash hands thoroughly after handling. Do not breathe spray, vapour. In case of mechanical malfunction, or if in contact with unknown dilution of product, wear full Personal Protective Equipment (PPE).
Keep away from heat and sources of ignition. Keep away from oxidizing agents. Keep out of reach of children. Keep container tightly closed. Store in suitable labeled containers.
Handle in accordance with good industrial hygiene and safety practice. Remove and wash contaminated clothing before re-use. Wash face, hands and any exposed skin thoroughly after handling. Provide suitable facilities for quick drenching or flushing of the eyes and body in case of contact or splash hazard.
Keep away from fire, sparks and heated surfaces. Take necessary action to avoid static electricity discharge (which might cause ignition of organic vapours).
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Effective exhaust ventilation system. Maintain air concentrations below occupational exposure standards.
No special protective equipment required.
Safety goggles Face-shield
None required if airborne concentrations are maintained below the exposure limit listed in Exposure Limit Information. Use certified respiratory protection equipment meeting EU requirements(89/656/EEC, (EU) 2016/425), or equivalent, when respiratory risks cannot be avoided or sufficiently limited by technical means of collective protection or by measures, methods or procedures of work organization.
No special protective equipment required.
Consider the provision of containment around storage vessels.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under normal conditions.
No dangerous reaction known under conditions of normal use.
No dangerous reaction known under conditions of normal use.
Heat, flames and sparks.
None known.
Depending on combustion properties, decomposition products may include following materials: Carbon oxides
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 3082
- Shipping Name
- ENVIRONMENTALLY HAZARDOUS SUBSTANCE, LIQUID, N.O.S. (Alcohol ethoxylate)
- Transport Class
- 9
- Packing Group
- III
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for ECOBRITE POWER COLOR?
The signal word is danger.
What is the physical form of ECOBRITE POWER COLOR?
ECOBRITE POWER COLOR is a liquid appearing as liquid with colourless color. It has odourless odor.
What is ECOBRITE POWER COLOR used for?
Laundry detergent
What are the hazard statements for ECOBRITE POWER COLOR?
This substance has 4 hazard statements:
- H302: Harmful if swallowed.
- H318: Causes serious eye damage.
- H400: Very toxic to aquatic life.
- H412: Harmful to aquatic life with long lasting effects.
What is the melting point of ECOBRITE POWER COLOR?
The melting point is Not applicable and/or not determined for the mixture and the boiling point is Not applicable and/or not determined for the mixture.