NextSDS Logo
Safety Data Sheet EN

ECOBRITE POWER COLOR

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
ECOBRITE POWER COLOR
Product Code
112286E

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Laundry detergent

Uses advised against

Reserved for industrial and professional use.

Manufacturers & Suppliers

E

ECOLAB

manufacturer

E

Ecolab Temizleme Sistemleri Ltd. Şti

national supplier

Esentepe Mahallesi, Cevizli - Esentepe E-5 Yanyol Caddesi, Vizyon Bulvar No: 13, Kat 1 No: 65 Turkey TR 34870 KARTAL / İSTANBUL

+90 (216) 458 69 00

E

Ecolab Gulf FZE

national supplier

P.O. Box 17063, Jebel Ali Free Zone Area, Near Container Terminal 3 - North Zone, Dubai UAE

00971 4 8014444

N

Nalco Egypt Trading

national supplier

5th Settlement, South 90th St., The Address Building No 67th – 1st floor, New Cairo, Cairo, Egypt 11835

0020 2 25 37 1195

E

Ecolab Maroc S.A.R.L.

national supplier

Batiment, Lot. Mounir 1, Parc Industriel, Attawfik, Route 1029 Sidi Maarouf, Casablanca, Morocco

00212 22 58 25 30 - 35

E

Ecolab Food Safety & Hygiene Solutions Pvt. Ltd

national supplier

WeWork, 247 Park Bus Stop, 13th floor, 247 Park, Hindustan C, LBS Road, Gandhi Nagar, Vikhroli West, Mumbai, Maharashtra. 400 079, India

+91 22 48808555, +91 22 48808535

Emergency Contacts

Trans-European

+32-(0)3-575-5555

Ulusal Zehir Danışma Merkezi (UZEM)

114

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Acute Tox. Cat. 4 H302
Eye Dam. Cat. 1 H318
Aquatic Acute Cat. 1 H400
Aquatic Chronic Cat. 3 H412

GHS Pictograms

GHS05 - Corrosive

GHS05

GHS07 - Health hazard

GHS07

GHS09 - Environmental hazard

GHS09

Hazard Statements

H302 Harmful if swallowed.
H318 Causes serious eye damage.
H400 Very toxic to aquatic life.
H412 Harmful to aquatic life with long lasting effects.

Precautionary Statements

P273 Avoid release to the environment.
P280 Wear eye protection/face protection.
P305 + P351 + P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
P310 Immediately call a POISON CENTER/doctor.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Alcohols, C13-15, branched and linear, ethoxylated 157627-86-6 30 - 50% Yes
Alcohols, C13-15, branched and linear, ethoxylated 157627-86-6 20 - 25% Yes
Isopropyl Alcohol EC: 200-661-7 67-63-0 1 - 2.5% Yes
Dipropylene glycol methyl ether EC: 252-104-2 34590-94-8 10 - 20% No
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove to fresh air. Treat symptomatically. Get medical attention if symptoms occur.

Skin contact

Rinse with plenty of water.

Eye contact

Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. Remove contact lenses, if present and easy to do. Continue rinsing. Get medical attention immediately.

Ingestion

Rinse mouth. Get medical attention if symptoms occur.

Immediate Medical Attention

Get medical attention immediately.

Medical Treatment

Treat symptomatically.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use extinguishing measures that are appropriate to local circumstances and the surrounding environment.

Unsuitable media

High volume water jet

Specific hazards

Fire Hazard. Keep away from heat and sources of ignition. Flash back possible over considerable distance.

Instructions

In the event of fire and/or explosion do not breathe fumes.

Firefighter Protection

Use personal protective equipment.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Ensure adequate ventilation. Remove all sources of ignition. Keep people away from and upwind of spill/leak. Avoid inhalation, ingestion and contact with skin and eyes. Ensure clean-up is conducted by trained personnel only.

Large spill

dike spilled material or otherwise contain material to ensure runoff does not reach a waterway.

Environmental

Do not allow contact with soil, surface or ground water.

Cleanup methods

collect with non-combustible absorbent material and place in container for disposal according to local / national regulations (see section 13). Flush away traces with water.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Do not ingest. Do not get in eyes, on skin, or on clothing. Use only with adequate ventilation. Keep away from fire, sparks and heated surfaces. Take necessary action to avoid static electricity discharge (which might cause ignition of organic vapours). Wash hands thoroughly after handling. Do not breathe spray, vapour. In case of mechanical malfunction, or if in contact with unknown dilution of product, wear full Personal Protective Equipment (PPE).

Storage

Keep away from heat and sources of ignition. Keep away from oxidizing agents. Keep out of reach of children. Keep container tightly closed. Store in suitable labeled containers.

Hygiene

Handle in accordance with good industrial hygiene and safety practice. Remove and wash contaminated clothing before re-use. Wash face, hands and any exposed skin thoroughly after handling. Provide suitable facilities for quick drenching or flushing of the eyes and body in case of contact or splash hazard.

Fire prevention

Keep away from fire, sparks and heated surfaces. Take necessary action to avoid static electricity discharge (which might cause ignition of organic vapours).

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Effective exhaust ventilation system. Maintain air concentrations below occupational exposure standards.

Hands

No special protective equipment required.

Eyes

Safety goggles Face-shield

Respiratory

None required if airborne concentrations are maintained below the exposure limit listed in Exposure Limit Information. Use certified respiratory protection equipment meeting EU requirements(89/656/EEC, (EU) 2016/425), or equivalent, when respiratory risks cannot be avoided or sufficiently limited by technical means of collective protection or by measures, methods or procedures of work organization.

Skin/Body

No special protective equipment required.

Environmental

Consider the provision of containment around storage vessels.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

State Under Standard Conditions
---
Properties Status
---
Solubility In Water
soluble
Melting Point
Not applicable and/or not determined for the mixture
Odor
odourless
Crystallisation Point
---
Upper Explosive Limit
Not applicable and/or not determined for the mixture
Solubility In Fat
---
Solidification Point
---
Lower Explosive Limit
Not applicable and/or not determined for the mixture
Cloud Point
---
Physical State Data
liquid
Decomposition Temperature
Not applicable and/or not determined for the mixture
Ph
8.0 - 8.6, 100 %
Kinematic Viscosity
51.639 mm2/s (40 °C)
Physical State
liquid
Partition Coefficient
Not applicable and/or not determined for the mixture
Bulk Density
---
Dynamic Viscosity
---
Metal Corrosion
---
Relative Evaporation Rate
---
Softening Point
---
Solubility
---
Freezing Point
Not applicable and/or not determined for the mixture
Relative Density
0.96 - 0.98
Odor Threshold
Not applicable and/or not determined for the mixture
Flash Point
80 °C closed cup
Auto Ignition Temperature
Not applicable and/or not determined for the mixture
Appearance
liquid
Vapor Pressure
Not applicable and/or not determined for the mixture
Colour
colourless
Molecular Weight
---
Boiling Point
Not applicable and/or not determined for the mixture
Evaporation Rate
Not applicable and/or not determined for the mixture
Colour Intensity
---
Explosive Limits
---
Form
---
Voc Content
---
Density
---
Vapor Density
---
Flammability
Not applicable and/or not determined for the mixture
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under normal conditions.

Reactivity

No dangerous reaction known under conditions of normal use.

Hazardous reactions

No dangerous reaction known under conditions of normal use.

Avoid

Heat, flames and sparks.

Incompatible

None known.

Decomposition

Depending on combustion properties, decomposition products may include following materials: Carbon oxides

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
3082
Shipping Name
ENVIRONMENTALLY HAZARDOUS SUBSTANCE, LIQUID, N.O.S. (Alcohol ethoxylate)
Transport Class
9
Packing Group
III
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for ECOBRITE POWER COLOR?

The signal word is danger.

What is the physical form of ECOBRITE POWER COLOR?

ECOBRITE POWER COLOR is a liquid appearing as liquid with colourless color. It has odourless odor.

What is ECOBRITE POWER COLOR used for?

Laundry detergent

What are the hazard statements for ECOBRITE POWER COLOR?

This substance has 4 hazard statements:

  • H302: Harmful if swallowed.
  • H318: Causes serious eye damage.
  • H400: Very toxic to aquatic life.
  • H412: Harmful to aquatic life with long lasting effects.

What is the melting point of ECOBRITE POWER COLOR?

The melting point is Not applicable and/or not determined for the mixture and the boiling point is Not applicable and/or not determined for the mixture.