NextSDS Logo
Safety Data Sheet EN

ZWALUW ACRYL-W

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
ZWALUW ACRYL-W

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Sealant

Uses advised against

No further relevant information available.

Manufacturers & Suppliers

DEN BRAVEN logo

DEN BRAVEN

manufacturer

Denariusstraat 11, 4903 RC Oosterhout, The Netherlands

+31 (0)162-491000

http://www.denbraven.com

D

Den Braven

manufacturer

+31 (0)162-491000

Emergency Contacts

Den Braven

+31 (0)162-491000

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Description: Mixture of substances listed below with nonhazardous additions.

Chemical Name CAS Number Concentration Hazardous
di-"isononyl" phthalate EC: 249-079-5 28553-12-0 1 - 5% Yes

For the wording of the listed risk phrases refer to section 16.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Supply fresh air; consult doctor in case of complaints.

Skin contact

Generally the product does not irritate the skin.

Eye contact

Rinse opened eye for several minutes under running water.

Ingestion

If symptoms persist consult doctor.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

CO2, powder or water spray. Fight larger fires with water spray or alcohol resistant foam.

Specific hazards

No further relevant information available.

Firefighter Protection

Mouth respiratory protective device.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Environmental

Do not allow to enter sewers/ surface or ground water.

Cleanup methods

Pick up mechanically.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Use only in well ventilated areas.

Storage

Requirements to be met by storerooms and receptacles: No special requirements. Information about storage in one common storage facility: Not required. Further information about storage conditions: None.

Fire prevention

No special measures required.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Hands

The glove material has to be impermeable and resistant to the product/ the substance/ the preparation. Due to missing tests no recommendation to the glove material can be given for the product/ the preparation/ the chemical mixture. Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation. The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer. As the product is a preparation of several substances, the resistance of the glove material can not be calculated in advance and has therefore to be checked prior to the application. The exact break trough time has to be found out by the manufacturer of the protective gloves and has to be observed.

Eyes

Goggles recommended during refilling

Respiratory

Not required.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Solubility
---
Ph
Undetermined.
Lower Explosive Limit
Undetermined.
Appearance
---
Relative Density
Not determined.
Physical State Data
liquid
Voc Content
0.99 %
Colour
Various colours
Flash Point
Not applicable.
Kinematic Viscosity
Not determined.
Solidification Point
---
Freezing Point
---
Auto Ignition Temperature
Undetermined.
Decomposition Temperature
Not determined.
Physical State
Pasty
Form
Pasty
Flammability
Not applicable.
Bulk Density
---
Relative Evaporation Rate
---
Evaporation Rate
Not determined.
Boiling Point
100 °C
Softening Point
---
Cloud Point
---
Vapor Density
Not determined.
Properties Status
---
Odor Threshold
Not determined.
Solubility In Fat
---
Colour Intensity
---
Molecular Weight
---
Crystallisation Point
---
Partition Coefficient
Not determined.
Solubility In Water
Not miscible or difficult to mix.
Upper Explosive Limit
Undetermined.
Odor
Characteristic
Explosive Limits
---
State Under Standard Conditions
---
Melting Point
Undetermined.
Vapor Pressure
Undetermined.
Dynamic Viscosity
Not determined.
Density
1.72 g/cm³
Metal Corrosion
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

No decomposition if used according to specifications.

Hazardous reactions

No dangerous reactions known.

Avoid

Thermal decomposition

Incompatible

No further relevant information available.

Decomposition

No dangerous decomposition products known.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for ZWALUW ACRYL-W?

The signal word is no signal word.

What is the physical form of ZWALUW ACRYL-W?

ZWALUW ACRYL-W is a pasty with various colours color. It has characteristic odor.

What is ZWALUW ACRYL-W used for?

Sealant

What is the melting point of ZWALUW ACRYL-W?

The melting point is Undetermined. and the boiling point is 100 °C.