NextSDS Logo
Safety Data Sheet EN

INTERTHANE 990E Base Ultra Light PT A

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
INTERTHANE 990E Base Ultra Light PT A
Product Code
RUA22A

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Professional use, Industrial use, Two component solvent borne coating for exterior use.

Uses advised against

Consumer use

Manufacturers & Suppliers

A

Akzo Nobel Performance Coatings, S.A. de C.V.

manufacturer

Anillo Periférico #205 Km16.64, Hacienda San José, García, Nuevo Leon, Mexico, CP 66000

1-800-589-1267

I

International Paint LLC

manufacturer

6001 Antoine Drive, Houston, Texas 77091

1-713-682-1711

A

Akzo Nobel Coatings Ltd.

manufacturer

4-110 Woodbine Downs Blvd., Etobicoke ON M9W 5S6, Canada

1-713-682-1711

Emergency Contacts

National advisory body/Poison Center

+44 (0)344 892 0111

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified warning

Hazard Classifications

Flam. Liq. Cat. 3 H226
Skin Sens. Cat. 1A H317

GHS Pictograms

GHS02 - Flammable

GHS02

GHS07 - Health hazard

GHS07

Hazard Statements

H226 Flammable liquid and vapor.
H317 May cause an allergic skin reaction.

Precautionary Statements

P210 Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
P261 Avoid breathing vapor.
P280 Wear protective gloves.
P302 + P352 IF ON SKIN: Wash with plenty of water.
P333 + P313 If skin irritation or rash occurs: Get medical advice or attention.
P362 + P364 Take off contaminated clothing and wash it before reuse.
P403 + P235 Store in a well-ventilated place. Keep cool.
P501 Dispose of contents and container in accordance with all local, regional, national or international regulations.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
n-butyl acetate EC: 204-658-1 123-86-4 10 - 15% Yes
Reaction mass of ethylbenzene and xylene EC: 905-588-0 --- 3% Yes
2-methoxy-1-methylethyl acetate EC: 203-603-9 108-65-6 0.3% Yes
Reaction mass of Bis (1,2,2,6,6-pentamethyl-4-piperidyl) sebacate and Methyl 1,2,2,6,6-pentamethyl-4-piperidyl sebacate EC: 915-687-0 1065336-91-5 0.21% Yes
butyl acrylate EC: 205-480-7 141-32-2 0.1% Yes
acrylic acid EC: 201-177-9 79-10-7 0.1% Yes
Phosphoric acid EC: 231-633-2 7664-38-2 0.1% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove victim to fresh air and keep at rest in a position comfortable for breathing. If not breathing, if breathing is irregular or if respiratory arrest occurs, provide artificial respiration or oxygen by trained personnel. It may be dangerous to the person providing aid to give mouth-to-mouth resuscitation. If unconscious, place in recovery position and get medical attention immediately. Maintain an open airway. Loosen tight clothing such as a collar, tie, belt or waistband.

Symptoms: No specific data.

Skin contact

Wash with plenty of soap and water. Remove contaminated clothing and shoes. Wash contaminated clothing thoroughly with water before removing it, or wear gloves. Continue to rinse for at least 10 minutes. In the event of any complaints or symptoms, avoid further exposure. Wash clothing before reuse. Clean shoes thoroughly before reuse.

Symptoms: Adverse symptoms may include the following: irritation redness

Eye contact

Immediately flush eyes with plenty of water for at least 15 minutes, occasionally lifting the upper and lower eyelids. Check for and remove any contact lenses if easy to do. Get medical attention if irritation occurs.

Symptoms: No specific data.

Ingestion

Wash out mouth with water. Remove dentures if any. If material has been swallowed and the exposed person is conscious, give small quantities of water to drink. Stop if the exposed person feels sick as vomiting may be dangerous. Do not induce vomiting unless directed to do so by medical personnel. If vomiting occurs, the head should be kept low so that vomit does not enter the lungs. Never give anything by mouth to an unconscious person. If unconscious, place in recovery position and get medical attention immediately. Maintain an open airway. Loosen tight clothing such as a collar, tie, belt or waistband.

Symptoms: sick

Immediate Medical Attention

Get medical attention if adverse health effects persist or are severe. If unconscious, place in recovery position and get medical attention immediately.

Medical Treatment

Treat symptomatically. No specific treatment.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use dry chemical, CO₂, water spray (fog) or foam.

Unsuitable media

Do not use water jet.

Specific hazards

Flammable liquid and vapor. Runoff to sewer may create fire or explosion hazard. In a fire or if heated, a pressure increase will occur and the container may burst, with the risk of a subsequent explosion.

Instructions

Promptly isolate the scene by removing all persons from the vicinity of the incident if there is a fire. No action shall be taken involving any personal risk or without suitable training. Move containers from fire area if this can be done without risk. Use water spray to keep fire-exposed containers cool.

Firefighter Protection

Fire-fighters should wear appropriate protective equipment and self-contained breathing apparatus (SCBA) with a full face-piece operated in positive pressure mode. Clothing for fire-fighters (including helmets, protective boots and gloves) conforming to European standard EN 469 will provide a basic level of protection for chemical incidents.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

No action shall be taken involving any personal risk or without suitable training. Evacuate surrounding areas. Keep unnecessary and unprotected personnel from entering. Do not touch or walk through spilled material. Shut off all ignition sources. No flares, smoking or flames in hazard area. Avoid breathing vapor or mist. Provide adequate ventilation. Wear appropriate respirator when ventilation is inadequate. Put on appropriate personal protective equipment.

Small spill

Stop leak if without risk. Move containers from spill area. Use spark-proof tools and explosion-proof equipment. Absorb with an inert material and place in an appropriate waste disposal container. Dispose of via a licensed waste disposal contractor.

Large spill

Stop leak if without risk. Move containers from spill area. Use spark-proof tools and explosion-proof equipment. Approach release from upwind. Prevent entry into sewers, water courses, basements or confined areas. Wash spillages into an effluent treatment plant or proceed as follows. Dispose of via a licensed waste disposal contractor. Contaminated absorbent material may pose the same hazard as the spilled product. Contain and collect spillage with non-combustible, absorbent material e.g. sand, earth, vermiculite or diatomaceous earth and place in container for disposal according to local regulations.

Environmental

Avoid dispersal of spilled material and runoff and contact with soil, waterways, drains and sewers.

Cleanup methods

Absorb with an inert material and place in an appropriate waste disposal container. Dispose of via a licensed waste disposal contractor. Wash spillages into an effluent treatment plant or proceed as follows.

Materials: inert material, non-combustible, absorbent material e.g. sand, earth, vermiculite or diatomaceous earth

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Put on appropriate personal protective equipment (see Section 8). Persons with a history of skin sensitization problems should not be employed in any process in which this product is used. Do not get in eyes or on skin or clothing. Do not ingest. Avoid breathing vapor or mist. Use only with adequate ventilation. Wear appropriate respirator when ventilation is inadequate. Do not enter storage areas and confined spaces unless adequately ventilated. Keep in the original container or an approved alternative made from a compatible material, kept tightly closed when not in use.

Storage

Keep in the original container or an approved alternative made from a compatible material, kept tightly closed when not in use. Store and use away from heat, sparks, open flame or any other ignition source.

Hygiene

Eating, drinking and smoking should be prohibited in areas where this material is handled, stored and processed. Workers should wash hands and face before eating, drinking and smoking. Remove contaminated clothing and protective equipment before entering eating areas.

Fire prevention

Store and use away from heat, sparks, open flame or any other ignition source.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Use only with adequate ventilation. Use process enclosures, local exhaust ventilation or other engineering controls to keep worker exposure to airborne contaminants below any recommended or statutory limits. The engineering controls also need to keep gas, vapor or dust concentrations below any lower explosive limits. Use explosion-proof ventilation equipment.

Hands

Chemical-resistant, impervious gloves complying with an approved standard should be worn at all times when handling chemical products if a risk assessment indicates this is necessary. Considering the parameters specified by the glove manufacturer, check during use that the gloves are still retaining their protective properties. It should be noted that the time to breakthrough for any glove material may be different for different glove manufacturers. In the case of mixtures, consisting of several substances, the protection time of the gloves cannot be accurately estimated. When prolonged or frequently repeated contact may occur, a glove with a protection class of 6 (breakthrough time >480 minutes according to EN374) is recommended. Recommended gloves: Viton ® or Nitrile, thickness ≥ 0.38 mm. When only brief contact is expected, a glove with protection class of 2 or higher (breakthrough time >30 minutes according to EN374) is recommended. Recommended gloves: Nitrile, thickness ≥ 0.12 mm. Gloves should be replaced regularly and if there is any sign of damage to the glove material. The performance or effectiveness of the glove may be reduced by physical/chemical damage and poor maintenance. The user must check that the final choice of type of glove selected for handling this product is the most appropriate and takes into account the particular conditions of use, as included in the user's risk assessment.

Eyes

Safety eyewear complying with an approved standard should be used when a risk assessment indicates this is necessary to avoid exposure to liquid splashes, mists, gases or dusts. If contact is possible, the following protection should be worn, unless the assessment indicates a higher degree of protection: safety glasses with side-shields.

Respiratory

Based on the hazard and potential for exposure, select a respirator that meets the appropriate standard or certification. Respirators must be used according to a respiratory protection program to ensure proper fitting, training, and other important aspects of use. Dry sanding, flame cutting and/or welding of the dry paint film will give rise to dust and/or hazardous fumes. Wet sanding/flatting should be used wherever possible. If exposure cannot be avoided by the provision of local exhaust ventilation, suitable respiratory protective equipment should be used. Wear a respirator conforming to EN140 with type A/P2 filter or better.

Skin/Body

Personal protective equipment for the body should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product. When there is a risk of ignition from static electricity, wear anti-static protective clothing. For the greatest protection from static discharges, clothing should include anti-static overalls, boots and gloves. Refer to European Standard EN 1149 for further information on material and design requirements and test methods. Appropriate footwear and any additional skin protection measures should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product.

Environmental

Emissions from ventilation or work process equipment should be checked to ensure they comply with the requirements of environmental protection legislation. In some cases, fume scrubbers, filters or engineering modifications to the process equipment will be necessary to reduce emissions to acceptable levels.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Flammability
---
Solubility In Fat
---
Ph
Not available. [DIN EN 1262]
Odor
Solvent.
Melting Point
Not available.
Kinematic Viscosity
Kinematic (room temperature): 224 mm²/s [DIN EN ISO 3219] Kinematic (40°C): 400 mm²/s [DIN EN ISO 3219]
Odor Threshold
Not available.
Solidification Point
---
Molecular Weight
---
Colour Intensity
---
Vapor Density
---
Evaporation Rate
---
Bulk Density
---
Cloud Point
---
Solubility In Water
Not soluble [OECD (TG 105)]
Softening Point
---
Dynamic Viscosity
---
Solubility
---
Decomposition Temperature
Not available.
Physical State
Liquid.
Explosive Limits
---
Properties Status
---
Form
---
Relative Evaporation Rate
---
Upper Explosive Limit
Greatest known range: Upper: 7.6% (n-butyl acetate)
Flash Point
Closed cup: 26°C (78.8°F) [Pensky-Martens]
Density
1.788 g/cm³ [DIN EN ISO 2811-1]
Freezing Point
---
Metal Corrosion
---
Voc Content
---
Boiling Point
126°C (258.8°F)
Appearance
---
Physical State Data
liquid
Partition Coefficient
Not applicable.
State Under Standard Conditions
---
Vapor Pressure
11.25096 mm Hg (1.5 kPa) [DIN EN 13016-2] (p-butyl acetate) (at 20°C)
Relative Density
---
Colour
White.
Auto Ignition Temperature
415°C (779°F) [EU A.15] (n-butyl acetate)
Lower Explosive Limit
Greatest known range: Lower: 1.4% (n-butyl acetate)
Crystallisation Point
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

The product is stable.

Reactivity

No specific test data related to reactivity available for this product or its ingredients.

Hazardous reactions

Under normal conditions of storage and use, hazardous reactions will not occur.

Avoid

Avoid all possible sources of ignition (spark or flame). Do not pressurize, cut, weld, braze, solder, drill, grind or expose containers to heat or sources of ignition.

Incompatible

oxidizing materials

Decomposition

Under normal conditions of storage and use, hazardous decomposition products should not be produced.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
UN1263
Shipping Name
PAINT
Transport Class
3
Packing Group
III
ADR

Transport within user's premises: always transport in closed containers that are upright and secure. Ensure that persons transporting the product know what to do in the event of an accident or spillage.

IMDG

Transport within user's premises: always transport in closed containers that are upright and secure. Ensure that persons transporting the product know what to do in the event of an accident or spillage.

IATA

Transport within user's premises: always transport in closed containers that are upright and secure. Ensure that persons transporting the product know what to do in the event of an accident or spillage.

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for INTERTHANE 990E Base Ultra Light PT A?

The signal word is warning.

What is the physical form of INTERTHANE 990E Base Ultra Light PT A?

INTERTHANE 990E Base Ultra Light PT A is a liquid. with white. color. It has solvent. odor.

What is INTERTHANE 990E Base Ultra Light PT A used for?

Professional use, Industrial use, Two component solvent borne coating for exterior use.

What are the hazard statements for INTERTHANE 990E Base Ultra Light PT A?

This substance has 2 hazard statements:

  • H226: Flammable liquid and vapor.
  • H317: May cause an allergic skin reaction.

What is the melting point of INTERTHANE 990E Base Ultra Light PT A?

The melting point is Not available. and the boiling point is 126°C (258.8°F).