Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- RSL3
- Product Code
- HY-100218A
Regulatory Identifiers
- CAS Number
- 1219810-16-8 Check regulations →
Identified Uses
Laboratory chemicals, manufacture of substances.
Manufacturers & Suppliers
MedChemExpress USA
manufacturer
1 Deer Park Dr, Suite F, Monmouth Junction, NJ 08852, USA
609-228-6898
Emergency Contacts
Emergency Contact
609-228-6898
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS07
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| (1S,3R)-RSL3 | 1219810-16-8 | --- | No |
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove person to fresh air and keep comfortable for breathing. Call a poison centre or physician if you feel unwell. If breathing is irregular or stopped, administer artificial respiration.
Where Diphoterine is not available, wash immediately with plenty of water and soap. Remove contaminated clothing immediately. Immediately seek medical attention.
Where Diphoterine is not available, rinse eyes with copious amounts of water for at least 20 minutes. Protect uninjured eye. Remove contact lenses if present and easy to do. Continue rinsing and seek immediate medical attention.
If accidentally swallowed rinse the mouth with plenty of water (only if the person is conscious) and obtain immediate medical attention. Do not induce vomiting.
Immediate Medical Attention
Seek immediate medical attention for eye contact, skin contact, and ingestion.
Medical Treatment
No special immediate treatment required
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Carbon dioxide, alcohol resistant foam or dry chemical powder., Use water to extinguish fire.
No known unsuitable media.
Thermal decomposition can lead to release of irritating gases and vapours.
Use extinguishing measures that are appropriate to local circumstances and the surrounding environment. Remove undamaged containers from fire area if it is safe to do so.
Firefighter Protection
Use personal protective equipment.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Keep personnel away from spill/leak.
Prevent further leakage if safe to do so. Discharge into the environment must be avoided.
Absorb the spilled material with an inert absorbent before transferring into an airtight container.
Materials: sand, silica gel, rag, vermiculite
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Wear appropriate personal protective equipment. Use only under a chemical fume hood. Keep away from heat/sparks/open flame/hot surfaces. Take measures to prevent the build-up of electrostatic charge. Ensure adequate exhaust ventilation, especially if dust, aerosol or fumes will be generated. Avoid contact with skin, eyes and clothing.
Keep container tightly sealed in cool, well-ventilated area. Keep away from direct sunlight and sources of ignition. Recommended storage temperature: 4°C, sealed storage, away from moisture. In solvent: -80°C, 2 years; -20°C, 1 year (sealed storage, away from moisture). Shipping at room temperature if less than 2 weeks.
Handle in accordance with good industrial hygiene and safety practice. Wash hands before and after use. Do not eat, drink or smoke when using this product. Remove and wash contaminated clothing before re-use.
Keep away from heat/sparks/open flame/hot surfaces. Take measures to prevent the build-up of electrostatic charge.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Use only under a chemical fume hood ensuring adequate ventilation, especially in confined areas. Use explosion-proof electrical/ventilating/lighting/equipment. Ensure that eyewash stations and safety showers are close to the workstation location.
Protective gloves.
Safety goggles with side-shields.
Suitable respirator.
Impervious clothing.
Avoid discharge into the environment, see section 6.2.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under recommended storage conditions.
No data available.
None under normal storage conditions.
Heat, sparks, open flames, sources of ignition. Exposure to moisture.
Strong acids/alkalis, strong oxidising/reducing agents.
Under fire conditions, may decompose and emit toxic fumes. Other decomposition products - no data available.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for RSL3?
The signal word is warning.
What is the physical form of RSL3?
RSL3 is a solid appearing as solid .
What is RSL3 used for?
Laboratory chemicals, manufacture of substances.
What are the hazard statements for RSL3?
This substance has 4 hazard statements:
- H302: Harmful if swallowed
- H315: Causes skin irritation
- H319: Causes serious eye irritation
- H335: May cause respiratory irritation