NextSDS Logo
Safety Data Sheet EN

Eni Blasia 220

Keep this SDS organized and up to date

Add this SDS to your NextSDS library and keep all its safety information in one place.

Add to my SDS library for free
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Eni Blasia 220
Product Form
Mixture
Product Code
2703

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Industrial use, Professional use, Wide dispersive use, Used in closed systems, Lubricant for gears, Lubricants and additives

Uses advised against

Do not use the product for any purposes that have not been advised by the manufacturer.

Manufacturers & Suppliers

E

Enilive S.p.A

manufacturer

Viale Giorgio Ribotta 51, 00144 Rome, ITALY

+39 06 59821

E

Enilive Schmiertechnik GmbH

distributor

Paradiesstraße 14, 97080 Würzburg, GERMANY

+49 (0)931-900 98-0

Emergency Contacts

CNIT

+39 0382 24444

24h

IT, EN

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Residual oils (petroleum,) solvent-refined; Baseoil—unspecified; [A complex combination by hydrocarbons obtained as the solvent insoluble fraction from solvent refining of a residuum using a polar organic solvent such as phenol or furfural. It consists of hydrocarbons having carbon numbers predominantly higher than C25 and boiling above approximately 400°C (752°F).] (Component, see note [*]) EC: 265-101-6 64742-01-4 50 - 60% No
Distillates (petroleum), solvent-dewaxed heavy paraffinic; Baseoil— unspecified; [A complex combination of hydrocarbons obtained by removal of normal paraffins from a petroleum fraction by solvent crystallization. It consists predominantly of hydrocarbons having carbon numbers predominantly in the range of C20 through C50 and produces a finished oil with a viscosity not less than 100 SUS at 100 °F (19cSt at 40 °C).] (see note [**], see note [*]) EC: 265-169-7 64742-65-0 40 - 50% No

A safety data sheet is not required for this product under Article 31 of REACH. This Product Safety Information Sheet has been created on a voluntary basis

Notes

: Note [*]: this product has a value of DMSO extract < 3 % wt, according to IP 346. According to the criteria laid out by the EU (note L, Annex VI of Regulation (CE) 1272/2008), this product must be regarded as non carcinogenic. Note [**]: this product may be formulated with one or more of the following base oils: CAS 74869-22-0/ EC: 278-012-2/ REACH Reg. # 01-2119495601-36-XXXX; CAS 64742-54-7/ EC 265-157-1/ REACH Reg. # 01-2119484627-25-XXXX

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

In case of disturbances owing to inhalation of vapours or mists, remove the victim from exposure; keep at rest; if necessary, seek medical attention.

Symptoms: Irritation to airways, nausea and dizziness (in case of overexposure to sprays and mists).

Skin contact

Take off contaminated clothing and shoes. Wash thoroughly with soap and water. If inflammation or irritation persists, seek medical advice. In case of burns, cool affected part with cold running water for at least 10 min. Cover with gauze or clean cloth. Ask for medical assistance or bring to a hospital. Do not apply salves or other substances, unless by doctor's advice. Body hypothermia must be avoided. Do not put ice on the burn.

Symptoms: Contact with hot product may cause thermal burns.

Eye contact

Rinse eyes thoroughly for at least 15 minutes. Keep eyelids well apart. Remove contact lenses, if present and easy to do. Continue rinsing. If irritation persists, seek medical advice. In case of burns, cool affected part with cold running water for at least 10 min. Cover with gauze or clean cloth. Ask for medical assistance or bring to a hospital. Do not apply salves or other substances, unless by doctor's advice.

Symptoms: Temporary reddening and irritation. Contact with hot product or vapours may cause burns.

Ingestion

Do not induce vomiting to avoid aspiration into the lungs. Keep at rest. If the person is conscious, rinse mouth with water without swallowing. Keep at rest. Call for medical assistance or bring to an hospital. If the casualty is unconscious, place in the recovery position. In case of spontaneous vomiting, keep head low, to avoid the risk of aspiration into the lungs. Do not give anything by mouth to an unconscious person.

Symptoms: Nausea, discomfort and gastric disturbances.

Immediate Medical Attention

Obtain medical attention if casualty has an altered state of consciousness or if symptoms do not resolve. Send patient to hospital. Seek medical attention in all cases of serious burns.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Small-size fires: carbon dioxide, dry chemicals, foam, sand or earth. Large fires: foam or water fog (mist). These means should be used by trained personnel only. Other extinguishing gases (according to regulations).

Unsuitable media

Do not use water jets. They could cause splattering, and spread the fire. Simultaneous use of foam and water on the same surface is to be avoided as water destroys the foam.

Specific hazards

This product is combustible, but not classified as Flammable. The creation of flammable vapour mixtures takes place at temperatures which are higher than normal ambient levels. The vapours are flammable and may form explosive mixtures with air.

Instructions

Shut off source of product, if possible. Spilled product which is not burning should be covered with sand or foam. Move containers away from the fire area if this can be done without risk. Use water sprays to cool containers and surfaces exposed to the flames. If the fire cannot be controlled, evacuate area.

Firefighter Protection

Wear personal protection equipment. (see chapter 8). EN 443. EN 469. EN 659. In case of a large fire or in confined or poorly ventilated spaces, wear full fire resistant protective clothing and self-contained breathing apparatus (SCBA) with a full face-piece operated in positive pressure mode.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Stop or contain leak at the source, if safe to do so. Eliminate all ignition sources if safe to do so (e.g. electricity, sparks, fires, flares). Avoid accidental sprays on hot surfaces or electrical contacts. Avoid direct contact with released material. Keep upwind. Keep non-involved personnel away from the area of spillage. Alert emergency personnel. Except in case of small spillages, the feasibility of any actions should always be assessed and advised, if possible, by a trained, competent person in charge of managing the emergency. If required, notify relevant authorities according to all applicable regulations.

Environmental

Do not let the product accumulate in confined or underground spaces. Do not let the product flow into sewers or water courses, or in any way contaminate the environment. In case of contamination of environment compartments (soil, subsoil, surface or underground waters), remove contaminated soil when possible, and in any case treat all involved compartments in accordance with local regulations. The site should have a spill plan to ensure that adequate safeguards are in place to minimize the impact of episodic releases.

Cleanup methods

Recover free liquid and waste materials in suitable waterproof and oil-resistant containers. Clean contaminated area.

Materials: suitable waterproof, oil resistant containers

—

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Ensure that all relevant regulations regarding handling and storage facilities of flammable products are followed. Use and store only outdoors or in a well-ventilated area. During transfer operations, ensure that all equipment and containers are correctly grounded. Avoid the build-up of electric charges. Emptied containers can contain combustible product residues. Do not cut, weld, drill, burn or incinerate empty containers or drums, unless they have been drained and cleaned. Before entering storage tanks and commencing any operation in a confined area (e.g. tunnels), carry out an adequate clean-up, and check the atmosphere for oxygen content, flammability, and the presence of sulphur compounds. Do not use compressed air for filling, discharging, or handling operations. Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.

Storage

Store in dry, well-ventilated area. Keep away from open flames, hot surfaces and sources of ignition. Do not smoke.

Hygiene

Avoid contact with skin. Do not breathe fume/ mist/ vapours. Do not ingest. Do not smoke. Do not eat and do not drink during use. Do not clean hands with dirty or oil-soaked rags. Do not re-use clothes, if they are still contaminated. Keep away from food and beverages.

Fire prevention

Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking. During transfer operations, ensure that all equipment and containers are correctly grounded. Avoid the build-up of electric charges.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Ensure that there is a suitable ventilation system. Before entering storage tanks and commencing any operation in a confined area (e.g. tunnels), check the atmosphere for oxygen content, presence of hydrogen sulphide (H2S) and SOx, and flammability. See also Section 16, "Other information".

Hands

When there is a risk of contact with the skin, use waterproof gloves, resistant to chemical products. Gloves must be felt-lined. Adequate materials: nitrile (NBR) or PVC with a protection index > 5 (permeation time > 240 mins). Use gloves respecting all the conditions and within the limits set by the manufacturer. Replace gloves immediately in case of cuts, holes or other signs of damages or degradation. If necessary, refer to the EN 374 standard.

Eyes

When there is a risk of contact with the eyes, use safety goggles or other means of protection (face shield). If necessary, refer to national standards or to the EN 166 standard.

Respiratory

Independently from other possible actions (technical modifications, operating procedures, and other means to limit the exposure of workers), personal protection equipment can be used according to necessity. Open or well ventilated spaces: in presence of oil mists and if the product is handled without adequate containment means: use full or half-face masks with filter for mists/aerosols (P). In case there is a significant presence of vapours (e.g. through handling at high temperature), use full or half-face masks with a filter for organic vapours (A), and H2S (B) where applicable. (EN 136/140/145). Combination filter device (DIN EN 141). Approved respiratory protection equipment shall be used in spaces where hydrogen sulphide may accumulate: full face mask with cartridge/filter type "B" (grey for inorganic vapours including H2S) or self-contained breathing apparatus (SCBA). (EN 136/140/145). Closed or confined areas (e.g. tank interiors): the use of protection measures for airways (masks or self-contained breathing apparatus), must be assessed according to the specific activity, as well as level and duration of predicted exposure.

Skin/Body

Long-sleeved overalls. If necessary, refer to the EN 340 and related standards, for definition of characteristics and performance according to the risk rating of the area. Antistatic non-skid safety shoes or boots, chemical resistant, if necessary heat resistant and insulated.

Environmental

Do not discharge the product into the environment. Storage areas/installations should be designed with adequate bunds so as to prevent ground and water pollution in case of leaks or spills. Prevent discharge of undissolved substance to or recover from onsite wastewater. Onsite wastewater treatment required. Do not apply industrial sludge to natural soils. Sludge should be incinerated, contained or reclaimed.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Language Code
---
Physical State
Liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
Liquid, bright & clear.
Colour
Yellow-brown.
Colour Intensity
---
Form
---
Odor
Slight odour of petroleum.
Odor Threshold
There are no data available on the preparation/mixture itself.
Ph
Not available
Melting Point
-18 °C (pour point) (ASTM D 97)
Boiling Point
207 – 750 °C (CAS 64742-01-4)
Flash Point
232 °C (ASTM D 92)
Freezing Point
≈ 0 °C (CAS 64742-01-4)
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
Negligible.
Evaporation Rate
---
Vapor Pressure
Not determined
Vapor Density
---
Relative Density
Not determined
Bulk Density
---
Density
896 kg/m³ (15 °C) (ASTM D 4052)
Flammability
Not flammable
Upper Explosive Limit
Not determined
Lower Explosive Limit
Not determined
Explosive Limits
---
Auto Ignition Temperature
> 300 °C (CAS 64742-01-4)
Decomposition Temperature
Not determined
Solubility
Water: Immiscible and insoluble
Partition Coefficient
Not applicable for mixtures
Solubility In Water
---
Solubility In Fat
---
Molecular Weight
Not applicable for mixtures
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
220 mm²/s (40 °C) (ASTM D 445)
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable product, according to its intrinsic properties.

Reactivity

This mixture does not offer any further hazard for reactivity, except what is reported in the following paragraphs.

Hazardous reactions

None (in normal conditions of storage and handling). Contact with strong oxidizers (peroxides, chromates, etc.) or alkali metals may cause a fire hazard.

Avoid

Sensitivity to heat, friction or shock cannot be assessed in advance.

Incompatible

strong oxidizers (peroxides, chromates, etc.) or alkali metals

Decomposition

Under normal conditions of storage and use, hazardous decomposition products should not be produced. Thermal decomposition generates : Carbon dioxide, Carbon monoxide, Toxic fumes. In exceptional cases (i.e prolonged storage in tanks contaminated with water, and presence of anaerobic sulfate-reducing microbial colonies), the product may undergo a degradation and generate small amounts of sulfur compounds, including H2S.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

12.1. Toxicity

Ecology - general : The product is not considered harmful to aquatic organisms nor to cause long-term adverse effects in the environment. An uncontrolled release to the environment may nevertheless produce a contamination of different environmental compartments (soil, underground, surface water bodies, aquifers). Handle according to general working hygiene practices to avoid pollution and release into the environment. Ecology - air : This product has a low vapour pressure, and in normal conditions at ambient temperature the concentration in the air is negligible. A significant concentration may build up only in case of sprays and mists. In these cases overexposure to mists (e.g. through prolonged use in confined insufficiently ventilated spaces) may cause irritation to airways, nausea and dizziness. Ecology - water : This product is not soluble in water. It floats on water and forms a film on the surface. The damage to aquatic organisms is of mechanical kind (immobilization and entrapment) Hazardous to the aquatic environment, short-term (acute) : Not classified Hazardous to the aquatic environment, long-term (chronic) : Not classified

The product is not considered harmful to aquatic organisms nor to cause long-term adverse effects in the environment. It is not soluble in water and floats on the surface, potentially causing mechanical damage to aquatic organisms.

12.1. Toxicity

| Residual oils (petroleum,) solvent-refined, Baseoil - unspecified (64742-01-4) | | | --- | --- | | LC50 fish 1 | > 100 mg/l (LL 50) | | EC50 Daphnia 1 | > 10000 mg/l WAF, 48 h (OECD 202) |

12.1. Toxicity

Distillates (petroleum), solvent-dewaxed heavy paraffinic (64742-65-0) | LC50 fish 1 | > 100 mg/l (LL 50, Exxon 1995 - OECD 203) | EC50 Daphnia 1 | > 10000 mg/l (EL50, Shell 1988 - OECD 202) | NOEC (acute) | ≥ 100 mg/l (Pseudokirchneriella subcapitata, 72h, OECD 201 - Petro-Canada 2008) | NOEC chronic fish | ≥ 1000 mg/l (Oncorhynchus mykiss, NOELR, 14d - QSAR, Redman, A. et al. 2010) | NOEC chronic crustacea | ≥ 1000 mg/l (21d, OECD 211 - Shell 1994) | NOEC chronic algae | ≥ 100 mg/l (Pseudokirchneriella subcapitata, 72h)

12.2. Persistence and degradability

12.2. Persistence and degradability

The most significant constituents of the product should be considered as "inherently biodegradable", but not "readily biodegradable", and they may be moderately persistent, particularly in anaerobic conditions.

The product's constituents are considered inherently biodegradable but not readily biodegradable, with potential for moderate persistence in anaerobic conditions.

12.2. Persistence and degradability

The most significant constituents of the product should be considered as "inherently biodegradable", but not "readily biodegradable", and they may be moderately persistent, particularly in anaerobic conditions.

The substance is considered inherently biodegradable but not readily biodegradable, with potential for moderate persistence in anaerobic conditions.

12.2. Persistence and degradability

The most significant constituents of the product should be considered as "inherently biodegradable", but not "readily biodegradable", and they may be moderately persistent, particularly in anaerobic conditions. Biodegradation: 31 % (28d, Exxon 1995)

12.3. Bioaccumulative potential

12.3. Bioaccumulative potential

| Eni Blasia 220 | | | --- | --- | | Log Pow | Not applicable for mixtures | | Log Kow | Not applicable for mixtures | | Bioaccumulative potential | Not established. |

Log Pow and Log Kow are not applicable for mixtures. Bioaccumulative potential is not established.

12.3. Bioaccumulative potential

| Distillates (petroleum), solvent-dewaxed heavy paraffinic (64742-65-0) | | | BCF fish 1 | 0.4 – 6280 l/kg | | BCF fish 2 | 3.16 – 71100 l/kg | | Log Pow | 1.99 – 18.02 | | Log Kow | Not applicable (UVCB) | | Bioaccumulative potential | The test methods for this endpoint are not applicable to UVCB substances. |

The test methods for this endpoint are not applicable to UVCB substances.

12.4. Mobility in soil

| Eni Blasia 220 | | | --- | --- | | Ecology - soil | No data available. | | Distillates (petroleum), solvent-dewaxed heavy paraffinic (64742-65-0) | | | Log Koc | 1.71 – 14.7 | | Ecology - soil | The test methods for this endpoint are not applicable to UVCB substances. |

12.5. Results of PBT and vPvB assessment

This substance/mixture does not meet the PBT criteria of REACH regulation, annex XIII. This substance/mixture does not meet the vPvB criteria of REACH regulation, annex XIII. Results of PBT-vPvB assessment: The components in this formulation do not meet the criteria for classification as PBT or vPvB. The product should be considered prudentially as "Persistent" in the environment, according to the REACH Annex XIII criteria (point 1.1). Substance(s) not meeting the PBT criteria of REACH regulation, in accordance with Annex XIII: Distillates (petroleum), solvent-dewaxed heavy paraffinic (64742-65-0). Substance(s) not meeting the vPvB criteria of REACH regulation, in accordance with Annex XIII: Distillates (petroleum), solvent-dewaxed heavy paraffinic (64742-65-0).

The substance/mixture does not meet PBT or vPvB criteria. Components do not meet criteria, though the product is prudentially considered 'Persistent' in the environment.

12.6. Endocrine disrupting properties

Adverse effects on the environment caused by endocrine disrupting properties : The mixture does not contain substance(s) included in the list established in accordance with Article 59(1) of REACH for having endocrine disrupting properties, or substance(s) are not identified as having endocrine disrupting properties in accordance with the criteria set out in Commission Delegated Regulation (EU) 2017/2100 or Commission Regulation (EU) 2018/605 at a concentration equal to or greater than 0,1 %.

The mixture does not contain substances with endocrine disrupting properties at a concentration equal to or greater than 0,1 %.

12.7. Other adverse effects

Other adverse effects Additional information : None. : This product has no specific properties for inhibition of bacterial activity. In any case, wastewater containing this product should be treated in plants that are suited for the specific purpose.

The product has no specific properties for inhibition of bacterial activity.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Do not dispose of the product, either new or used, by dumping on the ground, or discharging into sewers, tunnels, lakes or water courses. Deliver to a qualified official collector. Dispose of empty containers and wastes safely.

Disposal

European Waste Catalogue code(s) (Decision 2001/118/CE): 13 02 05* (mineral-based non-chlorinated engine, gear and lubricating oils). This EWC code is only a general indication, and takes into account the original composition of the product and its intended use. The user has the responsibility of choosing the right EWC code, considering the actual use of the product, alterations and contaminations.

Waste Codes

13 02 05* Mineral-based non-chlorinated engine, gear and lubricating oils EWC
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

A safety data sheet is not required for this product under Article 31 of REACH. This Product Safety Information Sheet has been created on a voluntary basis.

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Eni Blasia 220?

The signal word is no signal word.

What is the physical form of Eni Blasia 220?

Eni Blasia 220 is a liquid appearing as liquid, bright & clear. with yellow-brown. color. It has slight odour of petroleum. odor.

What is the solubility of Eni Blasia 220?

Water: Immiscible and insoluble

What is Eni Blasia 220 used for?

Industrial use, Professional use, Wide dispersive use, Used in closed systems, Lubricant for gears, Lubricants and additives

What is the melting point of Eni Blasia 220?

The melting point is -18 °C (pour point) (ASTM D 97) and the boiling point is 207 – 750 °C (CAS 64742-01-4).